@@ -172,12 +172,22 @@ use the secureboot installer image too. That is a separate project.
|
||||
## 5. Install
|
||||
|
||||
Boot the stick. Maintenance mode DHCPs untagged on every link; on these hosts
|
||||
that lands on `192.168.8.x`, which is routable from the workstation.
|
||||
that lands on `192.168.8.x`, which is routable from the workstation. It DHCPs on
|
||||
*every* link, so one machine answers on several addresses at once — they are the
|
||||
same host, not several hosts. `get disks` on each confirms it.
|
||||
|
||||
Maintenance mode is effectively write-only — `talosctl get` has no `--insecure`
|
||||
and `version` returns "API is not implemented in maintenance mode". You cannot
|
||||
inspect disks or links before applying. Verify serials and MACs from the host's
|
||||
PVE beforehand, in step 3.
|
||||
Maintenance mode does serve `talosctl get`. `--insecure` is a flag on the
|
||||
subcommand rather than a global, so it must come *after* `get` — placed before
|
||||
it, cobra resolves to the legacy `talosctl disks` command and reports
|
||||
`unknown flag: --insecure`:
|
||||
|
||||
```sh
|
||||
talosctl -n <maintenance-ip> get disks --insecure
|
||||
talosctl -n <maintenance-ip> get links --insecure
|
||||
```
|
||||
|
||||
Verify serials and MACs here, on the machine itself, against the config about to
|
||||
be applied.
|
||||
|
||||
Build the config from the **live cluster's secrets**, not a fresh
|
||||
`talosctl gen config`, or the node forms a new cluster instead of joining:
|
||||
@@ -202,13 +212,58 @@ Strip the generated `HostnameConfig` document — it collides with
|
||||
against a base with no `inlineManifests` (issue #581). Use only the additive
|
||||
second document.
|
||||
|
||||
Validate, then apply:
|
||||
Validate:
|
||||
|
||||
```sh
|
||||
talosctl validate --config install.yaml --mode metal
|
||||
talosctl apply-config --insecure -n <maintenance-ip> --file install.yaml
|
||||
```
|
||||
|
||||
### Install minimal, complete on the running node
|
||||
|
||||
Do **not** apply the full per-node config in maintenance mode. A document that
|
||||
references an interface which does not exist yet hangs the install: the node
|
||||
sits at `STAGE: Installing` indefinitely with `KUBELET n/a`, `APISERVER n/a`,
|
||||
and the console scrolling
|
||||
|
||||
```
|
||||
k8s.NodeApplyController: error getting node: nodes "k8s-N" not found
|
||||
```
|
||||
|
||||
That message is a symptom of an install that never finished, not a Kubernetes or
|
||||
networking fault — the node holds a DHCP address and is reachable throughout. On
|
||||
saturn the offenders were the `ens19` VLAN document and the sysctl naming it,
|
||||
`net.ipv6.conf.ens19.disable_ipv6`. Three cold installs hung on it; the identical
|
||||
config applied cleanly once the node was up. Wiping disks makes no difference —
|
||||
it is not leftover state.
|
||||
|
||||
**Stage 1** — the smallest config that installs and joins, plus `EPHEMERAL`,
|
||||
which is one-shot (section 7) and so cannot be deferred to stage 2:
|
||||
|
||||
```
|
||||
machine.network.hostname, machine.install.diskSelector, certSANs, nodeLabels
|
||||
LinkConfig <uplink>
|
||||
VLANConfig mgmt0
|
||||
DHCPv4Config mgmt0
|
||||
VolumeConfig EPHEMERAL
|
||||
```
|
||||
|
||||
```sh
|
||||
talosctl apply-config --insecure -n <maintenance-ip> --file install-stage1.yaml
|
||||
```
|
||||
|
||||
**Stage 2** — once the node is `Ready` and `talosctl etcd members` lists it,
|
||||
apply the full config to the running node. `--mode=try` reverts on its own if the
|
||||
network config is wrong, so it cannot strand the node; re-apply with
|
||||
`--mode=auto` to persist.
|
||||
|
||||
```sh
|
||||
talosctl -e <node-ip> -n <node-ip> apply-config --mode=try --timeout=3m --file install.yaml
|
||||
talosctl -e <node-ip> -n <node-ip> apply-config --mode=auto --file install.yaml
|
||||
```
|
||||
|
||||
Both applied without a reboot on saturn. Confirm `ens19`, `mgmt0` and the Ceph
|
||||
link are up afterwards with `talosctl get links` and `get addresses`.
|
||||
|
||||
## 6. The network config will strand the node if it is wrong
|
||||
|
||||
Talos stops running default DHCP operators **for the entire machine** as soon as
|
||||
@@ -334,7 +389,23 @@ The retired Crucial leaves a stale entry in `ceph device ls`. Remove it with
|
||||
cold rebuild is broken independently of this work.
|
||||
- Manual Woodpecker pipelines are broken (issue #582), so anything gated on
|
||||
`PIPELINE == "..."` must be run another way.
|
||||
- Cilium's eBPF datapath silently drops VLAN-tagged traffic unless
|
||||
`bpf.vlanBypass` is set. Both `mgmt0` and `ens19` are VLAN interfaces on a
|
||||
converted node. Not observed on jupiter, but it is the first place to look if
|
||||
the v30iot macvlan workloads misbehave there.
|
||||
- Cilium's eBPF datapath drops VLAN-tagged traffic unless `bpf.vlanBypass` is
|
||||
set. **This happened** — every v30iot macvlan workload on a converted node
|
||||
stayed in sandbox creation until `vlanBypass: [30]` was added (issue #592).
|
||||
|
||||
Only `ens19` is affected, and the reason is worth knowing: Cilium attaches to
|
||||
devices that carry an address. `cilium-dbg status --verbose` lists `mgmt0`
|
||||
among its devices but not `ens19`, because `ens19` is deliberately
|
||||
address-less. Cilium therefore owns `mgmt0` and sees VLAN 40 frames already
|
||||
untagged by the 8021q layer, while VLAN 30 frames only ever meet the filter
|
||||
on the shared parent `enp2s0f0np0`, still tagged. Any future address-less
|
||||
VLAN carrying pod traffic will need the same treatment.
|
||||
|
||||
The symptom does not look like a VLAN problem. A tc-layer drop reaches an
|
||||
AF_PACKET sender as ENOBUFS, so the CNI dhcp plugin reports `no buffer space
|
||||
available` and `network is down` rather than a DHCP timeout, and the pod sits
|
||||
in `ContainerCreating` behind `plugin type="macvlan" failed (add): error
|
||||
calling DHCP.Allocate: no more tries`. Confirm it with
|
||||
`cilium_drop_count_total{reason=~"VLAN.*"}` per node rather than by reading
|
||||
the CNI logs, and check `node_network_receive_packets_total{device="ens19"}`
|
||||
— it reads 0 on an affected node.
|
||||
|
||||
@@ -25,8 +25,11 @@ spec:
|
||||
# replaces the former hostNetwork attachment (see
|
||||
# network-attachment.yaml) so the NODE no longer holds an address
|
||||
# on the compromised IoT VLAN; MA gets its own leased IoT IP on
|
||||
# net1 instead. master: ens19 is the v30iot NIC on every k8s-{1,2,3}/edge
|
||||
# worker.
|
||||
# net1 instead. master: ens19 resolves on every k8s-{1,2,3}/edge
|
||||
# worker, though it is no longer the same kind of device everywhere:
|
||||
# on the bare-metal control-plane nodes it is a VLAN 30 sub-interface
|
||||
# of enp2s0f0np0 rather than a NIC, which is why the datapath needs
|
||||
# bpf.vlanBypass to carry it (issue #592).
|
||||
k8s.v1.cni.cncf.io/networks: music-assistant-iot
|
||||
spec:
|
||||
enableServiceLinks: false
|
||||
|
||||
@@ -33,6 +33,24 @@ spec:
|
||||
remediation:
|
||||
retries: 3
|
||||
values:
|
||||
# Roll the agent DaemonSet when cilium-config changes. Cilium reads
|
||||
# datapath options once, at agent start, and the chart puts no config
|
||||
# checksum on the pod template — so a changed ConfigMap leaves every agent
|
||||
# running the previous datapath until something restarts it. Nothing did.
|
||||
#
|
||||
# This is not hypothetical. vlan-bpf-bypass reached cilium-config and every
|
||||
# v30iot macvlan workload stayed broken until the agents were deleted by
|
||||
# hand, one node at a time (issue #592). policyMapMax has the same
|
||||
# exposure, and its comment below says "takes effect on agent restart" —
|
||||
# documentation standing in for automation.
|
||||
#
|
||||
# The trade: any cilium-config change now rolls the CNI cluster-wide,
|
||||
# node by node. That is disruptive-ish, but it is what a datapath change
|
||||
# already required — the difference is that it now happens on its own
|
||||
# instead of being forgotten. Reloader is already deployed for exactly
|
||||
# this pattern; named per-ConfigMap rather than blanket, as elsewhere.
|
||||
annotations:
|
||||
configmap.reloader.stakater.com/reload: cilium-config
|
||||
# Which pod labels feed security-identity computation. Patterns are
|
||||
# start-anchored regexes; a leading "!" excludes while keeping the default
|
||||
# set. Woodpecker stamps every step pod with woodpecker-ci.org/task-uuid
|
||||
@@ -73,6 +91,36 @@ spec:
|
||||
# kubernetes/talos/cilium.yaml carries a third copy of the same key.
|
||||
# Nothing enforces any of this; grep bpf-policy-map-max before changing it.
|
||||
policyMapMax: 65536
|
||||
# VLAN ids the eBPF datapath is allowed to pass. Without this it drops
|
||||
# VLAN-tagged frames, accounted as "VLAN traffic disallowed by VLAN
|
||||
# filter" in cilium_drop_count_total.
|
||||
#
|
||||
# 30 is v30iot, the macvlan parent for the shelly-manager, matter-server,
|
||||
# otbr and music-assistant attachments. On bare metal it is a VLAN
|
||||
# sub-interface of enp2s0f0np0; inside the former Proxmox guests it was
|
||||
# an untagged virtio NIC, which is why this was not needed before.
|
||||
#
|
||||
# VLAN 40 (mgmt0) is deliberately NOT listed, and the asymmetry is the
|
||||
# interesting part. Cilium attaches to devices that carry an address —
|
||||
# `cilium-dbg status --verbose` lists enp87s0, enp2s0f0np0, enp2s0f1np1
|
||||
# and mgmt0, but NOT ens19. mgmt0 holds the node IP, so Cilium owns it as
|
||||
# a device and sees frames the 8021q layer has already untagged; nothing
|
||||
# for a VLAN filter to match. ens19 is deliberately address-less (see
|
||||
# talos/patches/k8s-1.yaml — host addresses on that L2 make node replies
|
||||
# bypass the UDM), so Cilium never attaches to it and VLAN 30 frames only
|
||||
# meet the filter on the shared parent, still tagged.
|
||||
#
|
||||
# So the fix belongs on 30 alone. Listing 40 would change nothing, and
|
||||
# would touch the datapath carrying etcd and the API for no reason.
|
||||
#
|
||||
# A tc-layer drop surfaces to an AF_PACKET sender as ENOBUFS, so the
|
||||
# symptom is the CNI dhcp plugin reporting "no buffer space available"
|
||||
# rather than a DHCP timeout. See issue #592.
|
||||
#
|
||||
# Same three-copy problem as policyMapMax above: vlan-bpf-bypass in
|
||||
# kubernetes/talos/cilium.yaml and kubernetes/talos/patches/cilium-cni.yaml
|
||||
# must move with this list. Takes effect on agent restart.
|
||||
vlanBypass: [30]
|
||||
# Let pods reach the cluster's own LoadBalancer external IPs; Cilium
|
||||
# redirects the socket directly to the backend pod instead of sending
|
||||
# traffic out to the VIP and back (which fails with L2 announcements).
|
||||
|
||||
@@ -167,34 +167,44 @@ spec:
|
||||
# impossible: the OSD is recreated within a reconcile and starts backfilling
|
||||
# onto the drive being replaced.
|
||||
#
|
||||
# nvme0n1 on k8s-2/k8s-3 is the NVMe drive PCI-passed-through from saturn and
|
||||
# neptune, and is the only block device those guests can see, so a bare device
|
||||
# name is unambiguous there.
|
||||
#
|
||||
# k8s-1 is bare metal and sees three NVMe drives, so it names its OSD by
|
||||
# /dev/disk/by-id path instead. A bare name would be actively wrong: Talos
|
||||
# enumerates this machine's drives in a different order than Proxmox did, and
|
||||
# nvme0n1 here is the Kingston SYSTEM disk. Rook would probably decline it for
|
||||
# All three nodes are bare metal and see three NVMe drives each, so they name
|
||||
# their OSDs by /dev/disk/by-id path. A bare name would be actively wrong:
|
||||
# Talos enumerates these machines' drives in a different order than Proxmox
|
||||
# did, and the kernel name lands on the Kingston SYSTEM disk or on EPHEMERAL
|
||||
# depending on the boot. Rook would probably decline the system disk for
|
||||
# carrying partitions, but that is luck rather than intent. The by-id path is
|
||||
# derived from model and serial and does not depend on enumeration at all.
|
||||
#
|
||||
# nvme0n1 50026B7382B48B86 Kingston — Talos system disk
|
||||
# nvme1n1 2332E86B749A Crucial — Talos EPHEMERAL (/var)
|
||||
# nvme2n1 S437NX0M400426 PM983 — this OSD
|
||||
# k8s-3 demonstrated why: it enumerated the Kingston as nvme0n1 on one boot
|
||||
# and the Crucial as nvme0n1 on the very next one.
|
||||
#
|
||||
# k8s-1 (jupiter)
|
||||
# 50026B7382B48B86 Kingston — Talos system disk
|
||||
# 2332E86B749A Crucial — Talos EPHEMERAL (/var)
|
||||
# S437NX0M400426 PM983 — this OSD
|
||||
#
|
||||
# k8s-2 (saturn)
|
||||
# 50026B7382DA5F6E Kingston — Talos system disk
|
||||
# 2332E86B74BC Crucial — Talos EPHEMERAL (/var)
|
||||
# S437NX0M403161 PM983 — this OSD
|
||||
#
|
||||
# k8s-3 (neptune)
|
||||
# 50026B7382B48B90 Kingston — Talos system disk
|
||||
# 2326E6E8E67D Crucial — Talos EPHEMERAL (/var)
|
||||
# S437NF0M501176 PM983 — this OSD
|
||||
storage:
|
||||
useAllNodes: false
|
||||
useAllDevices: false
|
||||
nodes:
|
||||
# k8s-2 is absent while saturn's OSD drive is swapped and the node is
|
||||
# converted to bare metal. RE-ADD IT once the PM983 is in and the node has
|
||||
# rejoined, naming the device by /dev/disk/by-id as k8s-1 does — bare
|
||||
# metal sees three NVMe drives and the bare name is not the OSD.
|
||||
- name: k8s-3
|
||||
devices:
|
||||
- name: nvme0n1
|
||||
- name: k8s-1
|
||||
devices:
|
||||
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M400426
|
||||
- name: k8s-2
|
||||
devices:
|
||||
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M403161
|
||||
- name: k8s-3
|
||||
devices:
|
||||
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NF0M501176
|
||||
config:
|
||||
osdsPerDevice: "1"
|
||||
# Storage layer must never be evicted by kubelet under node pressure
|
||||
|
||||
@@ -5,31 +5,24 @@ metadata:
|
||||
namespace: rook-ceph
|
||||
spec:
|
||||
failureDomain: host
|
||||
# size 2, NOT 3. With 3 OSDs on 3 hosts, size=3 meant every write landed on
|
||||
# every drive in the cluster: per-drive write volume equalled total cluster
|
||||
# write volume, and all three drives wore at an identical rate and would have
|
||||
# reached end-of-rated-life together (measured 2026-08-19: 80/82/87% endurance
|
||||
# used, ~0.13 points/day, all three exhausted between Nov 2026 and Jan 2027 —
|
||||
# see #434). Replication does not protect against that failure mode, because
|
||||
# wear-out here is correlated by construction rather than independent.
|
||||
# size 3. This pool sat at 2 while the OSDs were Crucial P3 QLC drives: with
|
||||
# 3 OSDs on 3 hosts, size=3 put every write on every drive, so per-drive write
|
||||
# volume equalled total cluster write volume and all three wore at an
|
||||
# identical rate (measured 2026-08-19: 80/82/87% endurance used, ~0.13
|
||||
# points/day, all three projected to exhaust between Nov 2026 and Jan 2027 —
|
||||
# see #434). Replication does not protect against that, because the wear was
|
||||
# correlated by construction rather than independent.
|
||||
#
|
||||
# size 2 cuts per-drive write volume by a third and desynchronises the wear.
|
||||
# The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated
|
||||
# endurance with a far higher write budget, so wear-out is no longer the
|
||||
# binding constraint and the correlation argument no longer applies.
|
||||
#
|
||||
# min_size 1 is REQUIRED and deliberate. Ceph does not lower min_size when
|
||||
# size is reduced — it was 2 here, and leaving it would make the pool 2/2,
|
||||
# where any single OSD down (every rolling node reboot, every OSD restart)
|
||||
# min_size is left at the size-3 default of 2. The explicit min_size 1
|
||||
# override existed only because Ceph does not lower min_size when size is
|
||||
# reduced, which would have left the pool 2/2 — where any single OSD down
|
||||
# blocks IO for its PGs and hangs every RBD volume in the cluster.
|
||||
#
|
||||
# The trade this accepts: while the pool is degraded (one OSD down), a second
|
||||
# drive failing loses data, and with all three drives at 80%+ endurance that
|
||||
# window is not hypothetical. Mitigations that already exist: CNPG barman and
|
||||
# Velero both ship offsite to Hetzner (opentofu/object_storage.tf), so the
|
||||
# exposure is the RPO of those backups, not total loss. Keep node reboots
|
||||
# serialised and wait for HEALTH_OK between them.
|
||||
replicated:
|
||||
size: 2
|
||||
parameters:
|
||||
min_size: "1"
|
||||
size: 3
|
||||
---
|
||||
apiVersion: storage.k8s.io/v1
|
||||
kind: StorageClass
|
||||
@@ -87,39 +80,26 @@ metadata:
|
||||
name: cephfs
|
||||
namespace: rook-ceph
|
||||
spec:
|
||||
# TEMPORARY — RESTORE TO size 3 / no min_size OVERRIDE ONCE SATURN AND
|
||||
# NEPTUNE HAVE BOTH BEEN CONVERTED TO BARE METAL. It stays at 2/1 across all
|
||||
# three conversions rather than being toggled per node: each change
|
||||
# re-replicates the pool, and the window reopens with the next node anyway.
|
||||
# size 3 with no min_size override. This pool holds ~253 MiB against the data
|
||||
# pool's 280 GiB, and losing it would destroy the whole filesystem rather
|
||||
# than just the objects on the lost OSD, so it is the last pool that should
|
||||
# ever run thin.
|
||||
#
|
||||
# The standing trade for this pool is size 3: it holds ~253 MiB against the
|
||||
# data pool's 280 GiB, so it contributes nothing measurable to drive wear —
|
||||
# the entire reason data0 dropped to 2 — while losing it would destroy the
|
||||
# whole filesystem, not just the objects on the lost OSD. Paying 3x on a
|
||||
# quarter of a gigabyte to keep that intact is the right trade in steady
|
||||
# state.
|
||||
#
|
||||
# It does not hold while one of three hosts is out. size 3 on two remaining
|
||||
# hosts leaves every PG undersized at two copies with min_size 2, so a single
|
||||
# further OSD loss drops the pool below min_size and blocks IO on every
|
||||
# CephFS mount cluster-wide. At 2/1 the same two copies are active+clean
|
||||
# instead, and a further loss degrades rather than blocks — availability
|
||||
# bought at the cost of accepting writes onto a single copy while degraded.
|
||||
#
|
||||
# See RUNBOOK-baremetal-conversion.md.
|
||||
# It drops to 2/1 whenever one of the three hosts is out for longer than a
|
||||
# reboot. size 3 on two remaining hosts leaves every PG undersized at two
|
||||
# copies with min_size 2, so a single further OSD loss falls below min_size
|
||||
# and blocks IO on every CephFS mount cluster-wide. At 2/1 the same two
|
||||
# copies are active+clean instead, and a further loss degrades rather than
|
||||
# blocks. See RUNBOOK-baremetal-conversion.md.
|
||||
metadataPool:
|
||||
replicated:
|
||||
size: 2
|
||||
parameters:
|
||||
min_size: "1"
|
||||
size: 3
|
||||
dataPools:
|
||||
- name: data0
|
||||
# size 2 / min_size 1 for the same reasons as replicapool above — see
|
||||
# the comment there for the full rationale and the accepted trade.
|
||||
# size 3 for the same reasons as replicapool above — see the comment
|
||||
# there for why this pool sat at 2 while the Crucials backed the OSDs.
|
||||
replicated:
|
||||
size: 2
|
||||
parameters:
|
||||
min_size: "1"
|
||||
size: 3
|
||||
metadataServer:
|
||||
activeCount: 1
|
||||
activeStandby: true
|
||||
|
||||
@@ -310,6 +310,13 @@ data:
|
||||
# policy map (per endpoint). Keep in lockstep with patches/cilium-cni.yaml and
|
||||
# values.bpf.policyMapMax in kubernetes/infrastructure/cilium/helmrelease.yaml.
|
||||
bpf-policy-map-max: "65536"
|
||||
# VLAN ids the eBPF datapath may pass; without this it drops VLAN-tagged
|
||||
# frames. 30 is v30iot, the macvlan parent for the IoT workloads, and a VLAN
|
||||
# sub-interface of enp2s0f0np0 on bare metal. VLAN 40 (mgmt0) rides the same
|
||||
# parent but passes without an entry, so it is deliberately not listed.
|
||||
# Keep in lockstep with patches/cilium-cni.yaml and values.bpf.vlanBypass in
|
||||
# kubernetes/infrastructure/cilium/helmrelease.yaml. See issue #592.
|
||||
vlan-bpf-bypass: "30"
|
||||
# bpf-policy-stats-map-max specifies the maximum number of entries in global
|
||||
# policy stats map
|
||||
bpf-policy-stats-map-max: "65536"
|
||||
|
||||
@@ -331,6 +331,16 @@ cluster:
|
||||
# inline manifest, so a lower value here means a cold rebuild comes up with
|
||||
# a map that overflows until Flux reconciles.
|
||||
bpf-policy-map-max: "65536"
|
||||
# VLAN ids the eBPF datapath may pass; without this it drops
|
||||
# VLAN-tagged frames. 30 is v30iot, the macvlan parent for the IoT
|
||||
# workloads, and a VLAN sub-interface of enp2s0f0np0 on bare metal.
|
||||
# VLAN 40 (mgmt0) rides the same parent but passes without an entry,
|
||||
# so it is deliberately not listed. Keep in lockstep with
|
||||
# values.bpf.vlanBypass in kubernetes/infrastructure/cilium/helmrelease.yaml
|
||||
# and the third copy in kubernetes/talos/cilium.yaml — bootstrap installs
|
||||
# from this inline manifest, so omitting it here breaks the IoT macvlan
|
||||
# workloads until Flux reconciles. See issue #592.
|
||||
vlan-bpf-bypass: "30"
|
||||
# bpf-policy-stats-map-max specifies the maximum number of entries in global
|
||||
# policy stats map
|
||||
bpf-policy-stats-map-max: "65536"
|
||||
|
||||
@@ -1,7 +1,6 @@
|
||||
# k8s-2 runs Talos directly on saturn's MS-01 hardware. Structurally identical
|
||||
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
|
||||
# serials, MACs and addresses differ. k8s-3 is still a Proxmox VM and keeps the
|
||||
# VM-era layout until neptune is converted.
|
||||
# serials, MACs and addresses differ.
|
||||
machine:
|
||||
network:
|
||||
hostname: k8s-2
|
||||
|
||||
@@ -1,31 +1,82 @@
|
||||
# k8s-3 runs Talos directly on neptune's MS-01 hardware. Structurally identical
|
||||
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
|
||||
# serials and addresses differ. neptune was the last node converted, so all
|
||||
# three control-plane nodes now share this layout and no Proxmox remains.
|
||||
machine:
|
||||
network:
|
||||
hostname: k8s-3
|
||||
# Shared control-plane VIP — see k8s-1.yaml for the busPath rationale.
|
||||
interfaces:
|
||||
- deviceSelector:
|
||||
busPath: "0000:06:12.0"
|
||||
dhcp: true
|
||||
vip:
|
||||
ip: 10.2.40.60
|
||||
# v30iot: link only, no host addressing — see k8s-1.yaml.
|
||||
- deviceSelector:
|
||||
busPath: "0000:06:13.0"
|
||||
dhcp: false
|
||||
# See k8s-1.yaml for context on the dedicated Ceph cluster network.
|
||||
- deviceSelector:
|
||||
driver: i40e
|
||||
addresses:
|
||||
- 10.99.0.3/29
|
||||
mtu: 9000
|
||||
sysctls:
|
||||
# v30iot NIC carries no host addressing — see k8s-1.yaml.
|
||||
net.ipv6.conf.ens19.disable_ipv6: "1"
|
||||
install:
|
||||
disk: /dev/vda
|
||||
# Three NVMe drives are visible on bare metal. Select the installer target
|
||||
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
|
||||
# order the kernel enumerates them in — Talos and Proxmox do not agree on
|
||||
# that order.
|
||||
diskSelector:
|
||||
serial: 50026B7382B48B90
|
||||
certSANs:
|
||||
- k8s-3.srv.renner.uno
|
||||
nodeLabels:
|
||||
topology.kubernetes.io/zone: neptune
|
||||
cluster:
|
||||
allowSchedulingOnControlPlanes: true
|
||||
---
|
||||
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
|
||||
# drive is at 83% of its rated endurance and is finished as an OSD, but
|
||||
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
|
||||
# role. Available spare is still 100% and it reports no media errors.
|
||||
#
|
||||
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
|
||||
# solely when the volume does not yet exist; applied later it is silently
|
||||
# ignored and relocating needs a disk wipe and a boot from install media.
|
||||
#
|
||||
# Matched by serial deliberately: a broad selector such as
|
||||
# `disk.transport == 'nvme' && !system_disk` would match the PM983 as well.
|
||||
apiVersion: v1alpha1
|
||||
kind: VolumeConfig
|
||||
name: EPHEMERAL
|
||||
provisioning:
|
||||
diskSelector:
|
||||
match: disk.serial == '2326E6E8E67D'
|
||||
minSize: 50GiB
|
||||
grow: true
|
||||
---
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: mgmt0
|
||||
vlanID: 40
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
apiVersion: v1alpha1
|
||||
kind: DHCPv4Config
|
||||
name: mgmt0
|
||||
---
|
||||
# Shared control-plane VIP, held by whichever node wins the etcd campaign.
|
||||
apiVersion: v1alpha1
|
||||
kind: Layer2VIPConfig
|
||||
name: 10.2.40.60
|
||||
link: mgmt0
|
||||
---
|
||||
# v30iot: link only, no host addressing — see k8s-1.yaml.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: ens19
|
||||
vlanID: 30
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Dedicated Ceph cluster network — see k8s-1.yaml.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f1np1
|
||||
up: true
|
||||
mtu: 9000
|
||||
addresses:
|
||||
- address: 10.99.0.3/29
|
||||
|
||||
@@ -47,8 +47,13 @@ variable "tags" {
|
||||
}
|
||||
|
||||
variable "template_name" {
|
||||
type = string
|
||||
default = "ubuntu-24-04-template"
|
||||
type = string
|
||||
# No default clone source. The ubuntu-24.04-template it used to name was
|
||||
# deleted with saturn's conversion to bare metal, and Proxmox is being
|
||||
# retired, so a default pointing at a template that does not exist would
|
||||
# only fail at apply time. Set it explicitly if a clone source is ever
|
||||
# wanted again.
|
||||
default = null
|
||||
}
|
||||
|
||||
variable "full_clone" {
|
||||
|
||||
@@ -1,71 +0,0 @@
|
||||
resource "proxmox_virtual_environment_vm" "ubuntu_24_04_template" {
|
||||
name = "ubuntu-24.04-template"
|
||||
node_name = "saturn"
|
||||
vm_id = 605
|
||||
|
||||
started = false
|
||||
template = true
|
||||
on_boot = false
|
||||
|
||||
keyboard_layout = "en-us"
|
||||
|
||||
bios = "seabios"
|
||||
|
||||
agent {
|
||||
enabled = true
|
||||
}
|
||||
|
||||
cpu {
|
||||
cores = 2
|
||||
type = "x86-64-v3"
|
||||
}
|
||||
|
||||
memory {
|
||||
dedicated = 2048
|
||||
}
|
||||
|
||||
initialization {
|
||||
datastore_id = "local-zfs"
|
||||
|
||||
ip_config {
|
||||
ipv4 {
|
||||
address = "dhcp"
|
||||
}
|
||||
}
|
||||
|
||||
user_account {
|
||||
username = "ladmin"
|
||||
keys = [
|
||||
"ssh-ed25519 AAAAC3NzaC1lZDI1NTE5AAAAIPzFNBP3bq2m/6JqDqod9w+FP/uxXxHMolqhq3Ojflr1 krenner@fortress"
|
||||
]
|
||||
}
|
||||
}
|
||||
|
||||
disk {
|
||||
datastore_id = "local-zfs"
|
||||
interface = "scsi0"
|
||||
size = 32
|
||||
file_format = "raw"
|
||||
iothread = false
|
||||
}
|
||||
|
||||
network_device {
|
||||
bridge = "v40srv"
|
||||
model = "virtio"
|
||||
}
|
||||
|
||||
serial_device {}
|
||||
|
||||
scsi_hardware = "virtio-scsi-pci"
|
||||
|
||||
lifecycle {
|
||||
ignore_changes = [
|
||||
node_name,
|
||||
started,
|
||||
initialization,
|
||||
disk,
|
||||
cpu,
|
||||
memory
|
||||
]
|
||||
}
|
||||
}
|
||||
Reference in New Issue