Cilium reads datapath options once, at agent start, and the chart puts no
config checksum on the pod template. A changed ConfigMap therefore leaves every
agent running the previous datapath until something restarts it, and nothing
does — the DaemonSet is not rolled by a ConfigMap-only Helm change.
This already cost an outage. vlan-bpf-bypass landed in cilium-config and every
v30iot macvlan workload stayed broken until the agents were deleted by hand,
one node at a time (issue #592). The merge looked successful: HelmRelease
Ready, release upgraded, key present in the ConfigMap, and nothing working.
policyMapMax carries the same exposure. Its comment says "takes effect on agent
restart", which is documentation standing in for automation — as does the
equivalent note in the two bootstrap copies.
Reloader is already deployed and used across the repo for the same purpose.
Named per-ConfigMap rather than blanket, matching the existing convention.
The trade, stated plainly: any cilium-config change now rolls the CNI
cluster-wide, node by node. That is the same disruption a datapath change
already required; the difference is that it happens on its own rather than
being forgotten.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Every v30iot macvlan workload on a bare-metal node has been stuck in sandbox
creation since its node was converted. Cilium's datapath drops VLAN-tagged
frames unless bpf.vlanBypass lists the tag, and cilium-config carried no
vlan-bpf-bypass key at all.
Inside the Proxmox guests ens19 was an untagged virtio NIC on the v30iot
bridge, so nothing was tagged by the time Cilium saw it. On bare metal ens19 is
a VLAN 30 sub-interface of enp2s0f0np0, and the macvlan children's DHCP
exchange never reaches the wire.
Measured rather than inferred: cilium_drop_count_total on the affected node
reports ~123k INGRESS and ~1.1k EGRESS drops with reason "VLAN traffic
disallowed by VLAN filter", against none on the node that was still a VM, and
node_network_receive_packets_total for ens19 reads 0 there against 10 pkt/s on
the VM. Full analysis in issue #592.
The symptom hides its own cause. A tc-layer drop surfaces to an AF_PACKET
sender as ENOBUFS, so the CNI dhcp plugin reports "no buffer space available"
and "network is down" instead of a DHCP timeout.
VLAN 40 is deliberately not listed. mgmt0 rides the same parent and carries the
node IP, etcd and the API, and it passes today without a bypass entry, so
adding it would change a working control-plane datapath to fix an IoT one.
All three copies of the key move together — the HelmRelease, kubernetes/talos/
cilium.yaml, and the inline bootstrap manifest in patches/cilium-cni.yaml — so
a cold rebuild does not come up without it.
The runbook predicted this exact failure and is updated to record that it
happened, along with how to recognise it from the drop counters rather than the
misleading CNI error. music-assistant's comment claiming ens19 is "the v30iot
NIC" on every node is corrected; it is a NIC on the edge worker and a VLAN
sub-interface on the control-plane nodes.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
These two sat at size 2 because of #434, not because of the conversion. With
three Crucial P3 QLC OSDs on three hosts, size 3 put every write on every
drive, so per-drive write volume equalled cluster write volume and all three
wore at an identical rate — 80/82/87% of rated endurance, projected to exhaust
together between Nov 2026 and Jan 2027. Replication is no defence against that,
because the wear was correlated by construction.
The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated endurance
with a far higher write budget. Wear-out is no longer the binding constraint
and the correlation argument no longer applies, so the pools return to the
durability the cluster is sized for.
The min_size 1 overrides go with them. They existed only because Ceph does not
lower min_size when size is reduced, which would have left the pools 2/2 and
blocked IO on any single OSD going down.
cephfs-metadata's comment loses the clause explaining that data0 sits at 2,
which stops being true here.
cephfs-ci stays at size 2: that pool holds throwaway CI workspaces and is at 2
rather than 1 only because an unreplicated pool makes `ceph osd ok-to-stop`
refuse for every OSD. Unrelated to #434.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
All three nodes are converted and the cluster is back to three OSDs across
three zones with 217 PGs active+clean, so the conversion window that justified
2/1 on this pool is over.
The min_size override goes with it. It existed only because Ceph does not
lower min_size when size is reduced, so the pool would have been 2/2 while a
host was out. At size 3 the default min_size of 2 is what the pool wants.
The comment loses its TEMPORARY banner and now states the standing rationale
and the condition under which the pool degrades to two copies.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
neptune is converted and back in the cluster, so k8s-3 returns to the storage
fleet on its new PM983. All three nodes now name their OSD by /dev/disk/by-id,
and the storage fleet is whole again.
The comment generalises to all three nodes and records neptune's serials.
k8s-3 is the clearest evidence for by-id addressing: it enumerated the Kingston
as nvme0n1 on one boot and the Crucial as nvme0n1 on the very next one, so a
kernel-name reference had no stable meaning on that machine at all.
The old osd.1 lived on the Crucial that is now EPHEMERAL. That drive was wiped
during the conversion, so the OSD is unrecoverable and is purged from the CRUSH
map separately; this change only creates its replacement.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
neptune now runs Talos directly, so k8s-3 moves from the VM-era layout to the
multi-document form k8s-1 and k8s-2 already use. The old config selected
interfaces by busPath against virtio NICs and installed to /dev/vda; neither
exists on bare metal.
Disks are selected by serial rather than kernel name. That is not defensive
styling: Talos enumerated this machine's drives differently than Proxmox did,
and differently again between two consecutive boots — nvme0n1 was the Kingston
on one boot and the Crucial on the next. A device-name reference would have
installed onto the wrong drive.
nvme 50026B7382B48B90 Kingston system disk
nvme 2326E6E8E67D Crucial EPHEMERAL, 83% of rated endurance
nvme S437NF0M501176 PM983 OSD, 3% used
Serials, interface names and drive health were read from the machine itself —
the Kingston and Crucial off the running Proxmox host before the wipe, and
confirmed again from Talos maintenance mode.
k8s-2.yaml loses the sentence claiming k8s-3 is still a Proxmox VM. No Proxmox
remains in the homelab.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
neptune is the last node to convert to bare metal, and its OSD drive is swapped
in the same window. Removing k8s-3 from the explicit node list first means Rook
stops managing that OSD before the drive it lives on goes away, rather than
recreating it mid-reconcile and backfilling onto a disk that is about to be
pulled.
The device comment for k8s-3 goes with it: it described the PCI-passed-through
drive that node saw as a Proxmox guest, which stops being true here.
Ceph runs on two OSDs and size-3 pools stay degraded until the node rejoins.
cephfs-metadata is already at 2/1 for exactly this window.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
saturn is back on bare metal with the PM983 in place, so k8s-2 returns to the
storage fleet. Like k8s-1 it names the device by /dev/disk/by-id: the machine
has three NVMe drives and Talos enumerates them differently than Proxmox did,
so nvme0n1 there is the Kingston system disk.
The runbook prescribed applying the full per-node config in maintenance mode,
which hangs the install. A document referencing an interface that does not
exist yet leaves the node at STAGE: Installing with KUBELET n/a, the console
repeating
k8s.NodeApplyController: error getting node: nodes "k8s-N" not found
which reads as a Kubernetes fault but is an install that never completed. On
saturn it was the ens19 VLAN document and the sysctl naming it. Three cold
installs hung; the identical config applied cleanly to the running node.
Wiping disks changes nothing.
Install now runs in two stages: a minimal network config plus EPHEMERAL, which
is one-shot and cannot be deferred, then the full config applied to the running
node behind --mode=try so a bad network config reverts itself.
Also corrects the claim that maintenance mode cannot be inspected. talosctl get
works there; --insecure is a subcommand flag and has to follow `get`, otherwise
cobra resolves the legacy `talosctl disks` command and rejects the flag.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
VM 605 is pinned to saturn, so it cannot survive the conversion, and it has to
go before the node leaves the Proxmox cluster — afterwards the provider cannot
reach it and every plan errors.
Nothing uses it. Its purpose was cloning new Proxmox VMs, Proxmox is being
retired, and the one remaining VM definition sets template_name = null
explicitly rather than cloning from it.
The module default is changed to null for the same reason: it named a template
that no longer exists, which would only surface as an apply-time failure for
whoever created the next VM.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
saturn is being converted to bare metal, so its VM definition goes and it
leaves the list of Proxmox nodes the pipeline seeds the nocloud image onto.
The apply must run while saturn is still a Proxmox cluster member. Once it
leaves, the provider cannot reach the node, the plan errors, and the only way
out is tofu state rm.
module.k8s_2 is referenced nowhere else in opentofu/, so this destroys exactly
one resource.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Structurally identical to k8s-1.yaml; only serials, MACs and addresses differ.
Written from saturn's live hardware rather than assumed: the X710 port 1 MAC
came from the guest that currently owns it, since the host cannot see a
passed-through NIC.
Kingston 50026B7382DA5F6E system disk
Crucial 2332E86B74BC EPHEMERAL, retiring from osd.0 at 81% wear
X710 p0 58:47:ca:76:6f:73 trunk, VLAN 40 + VLAN 30
X710 p1 58:47:ca:76:6f:74 Ceph cluster network, 10.99.0.2/29
Links are addressed by kernel name rather than LinkAliasConfig, and both disks
by serial. Talos and Proxmox do not agree on NVMe enumeration order, and a
network document that fails to resolve takes the whole machine's DHCP with it.
Not applied by anything on merge — talos patches are applied by hand. Landing
it before the conversion so the file under review is the file that gets
installed.
Verified with talosctl validate --mode metal against v1.12.6.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Removing the node from storage.nodes before purging its OSD is what makes the
purge stick. Under useAllNodes the operator rebuilt a purged OSD within one
reconcile and began backfilling onto the drive being replaced; listing nodes
explicitly exists so a node can be taken out first.
Re-add after the conversion naming the device by /dev/disk/by-id, as k8s-1
does. A bare device name is not safe on bare metal: Talos enumerates the three
NVMe drives in a different order than Proxmox, and nvme0n1 is the system disk.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
pvecm expected 1 is the official recovery, documented verbatim in the storage
replication chapter of the Proxmox admin guide. Its caveat is about restoring
the missing node instead; here the missing node is deliberately gone for good,
so enforcing quorum is the correct branch rather than a workaround.
Also records that it must be run only once the node is alone -- corosync
rejects a value below the members it can see, which is why the attempt on the
current two-node cluster returned CS_ERR_INVALID_PARAM -- and that it is
runtime only.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
jupiter is converted and its OSD rebuilt, so the capacity constraint that took
immich down is gone with all three nodes back.
cephfs-metadata deliberately stays at size 2 / min_size 1. It has to be
degraded again for saturn and then neptune, and each transition re-replicates
the pool, so toggling it per node buys nothing but churn. Its comment said to
restore it once k8s-1 was back, which is now misleading about the plan; it
restores after the last conversion instead.
The immich comments lose their jupiter-specific framing — taking both
Deployments down is a pre-flight step for any single-node maintenance now, and
the runbook carries it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Written from doing jupiter, with saturn and neptune still to go. The conversion
itself was straightforward; every failure came from state that outlived the VM,
so the runbook is weighted towards those rather than towards the happy path.
The three that cost real time:
A rebuilt node gets a new MAC and a new lease, and Ceph keeps its mon pinned to
the old address in the monmap, the mon-endpoints ConfigMap and the deployment's
--public-addr. The mon then cannot bind, the operator's next step wants to
restart a healthy mon, Ceph refuses because that would drop quorum, and it
retries every minute forever without reaching the storage reconcile. Fixing the
ConfigMap before the monmap and the deployment matters, or the operator
recreates the mon from the stale entry.
Talos stops running default DHCP for the whole machine as soon as one new-style
network document exists, and a LinkAliasConfig selector that matches nothing is
skipped silently. Together those turn a small config mistake into a node with no
address on any interface.
EPHEMERAL placement is honoured only on first provision, so it has to be right
in the first apply-config; afterwards it is ignored and relocating needs a wipe.
Also records the Proxmox quorum step that starts mattering at the second
conversion, the Secure Boot blocker, and that Talos and Proxmox enumerate the
same three NVMe drives in different orders — which is why the OSD is named by
by-id path rather than device name.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
jupiter is back as a bare-metal Talos node, so its OSD returns to the storage
fleet on the new drive.
The device is named by /dev/disk/by-id rather than by bare device name, because
the bare name would be wrong here. Talos enumerates this machine's three NVMe
drives in a different order than Proxmox did, and nvme0n1 on k8s-1 is the
Kingston system disk:
nvme0n1 50026B7382B48B86 Kingston Talos system disk
nvme1n1 2332E86B749A Crucial Talos EPHEMERAL (/var)
nvme2n1 S437NX0M400426 PM983 this OSD
Rook would most likely have declined the system disk for carrying partitions,
but relying on that is luck rather than intent. The by-id path derives from
model and serial and does not depend on enumeration order.
k8s-2 and k8s-3 keep bare names: each guest sees exactly one block device,
the drive passed through from its host, so there is nothing to disambiguate.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The first install of this node came up with no address on any interface and had
to be recovered from the console. This is the configuration that replaced it,
now running on jupiter.
The alias layer was the cause, but not for the reason it first appeared. Reading
the v1.12.6 source: aliases ARE supported as VLAN parents — link_config.go
resolves parent links through the alias map, and the field's own doc comment
says so. The structure was fine. What is not fine is the failure behaviour.
LinkAliasConfigController skips a selector that matches zero links with no log
of any kind, contradicting the doc comment on the type which claims an error is
returned. And permanent_addr comes from the ETHTOOL_GPERMADDR ioctl with no
fallback to the current address, so a driver that does not answer it yields an
empty string, an unmatched glob, and silence.
That alone would have been survivable. What made it total is that Talos stops
running default DHCP operators for the WHOLE machine as soon as a single
new-style link, VLAN or DHCP document exists — the gate is presence of a
document, not success of resolution. So the silent miss removed the only
configured path while the safety net was already disabled. There is no fail-open
option.
Aliases are worth having and should come back. The condition is that they are
verified rather than assumed: apply with `--mode=try`, which rolls back on its
own, and check that linkaliasspec exists and that permanentAddr is actually
populated before trusting it. A LinkConfig on the real kernel name alongside the
alias resolves regardless of whether the alias landed, and costs nothing.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Three NVMe drives are present, not two: the Crucial stays in the machine as
EPHEMERAL rather than being pulled.
The second I226 is enp90s0, not enp89s0. Adding that third drive renumbered
the PCI buses and renamed it, which is a concrete demonstration of why every
NIC in this file is matched by permanent MAC rather than by name or bus path.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The Crucial P3 that was this node's Ceph OSD stays in the machine rather than
being pulled, and takes over /var. At 87% of rated endurance it is finished as
an OSD, but everything EPHEMERAL holds — containerd images and snapshots, pod
logs, the Ceph mon store — is reconstructible, so the drive is consumable in
that role.
It also removes the constraint that keeps biting elsewhere: /var becomes
~931 GB instead of the 64 GB the VM-era zvol gave it. k8s-3 tripped
DiskPressure twice today the moment it absorbed another node's pods, with
image GC already at its floor and ~20 GB of unreclaimable overlayfs snapshots.
This node will not have that problem, and the same treatment is available to
saturn and neptune when they convert.
Talos only honours volume configuration when the volume does not yet exist, so
this must ship in the first apply-config; applied later it is silently ignored
and relocating EPHEMERAL then needs a disk wipe and a boot from install media.
The selector matches an exact serial. There are three NVMe drives in this
machine now and `disk.transport == 'nvme' && !system_disk` would match the
PM983 as well, which would hand Talos the OSD drive.
Verified with talosctl validate --mode metal against v1.12.6.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
With one of three nodes out for the bare-metal conversion, the remaining pair
cannot hold the workload: cluster CPU requests exceed two nodes' capacity by
roughly 200m once DaemonSets and unplaceable Ceph pods are discounted, and
k8s-3 sits ~5.8 GiB above the kubelet's eviction threshold with image GC
already at its floor.
immich is the right thing to stop rather than squeeze. machine-learning
reserves 500m against a 2m idle draw, but inference bursts hard, so cutting
its request would misrepresent what it needs the moment someone uploads
photos. Stopping it removes the reservation honestly, and takes its pods and
image pulls off k8s-3 for the duration.
The Postgres cluster stays up, so recovery is these two replica counts and
nothing else.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
useAllNodes makes it impossible to retire an OSD ahead of pulling its drive.
Purging osd.2 and deleting its deployment held for one reconcile: the operator
saw a node it was told to use, carrying a device with a BlueStore signature,
and rebuilt the OSD. Ceph then began backfilling onto the very drive being
replaced.
Listing nodes explicitly makes membership of the storage fleet a property of
this file rather than of which nodes happen to exist, so a node can be removed
before its disk is touched.
k8s-1 is out while jupiter's OSD is swapped for the PM983 and the node is
converted to bare metal. The cluster runs on two OSDs until it is re-added;
all pools are size 2 / min_size 1 and stay fully redundant across the pair.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Draining k8s-1 for the jupiter conversion left three pods unschedulable:
k8s-2 and k8s-3 both sat at 100% of requested CPU while actually using 21-23%.
Cluster-wide the gap is 19,680m requested against 7,957m used.
crowdsec is the clearest single contributor. The chart defaults reserve 500m
for each agent and for the LAPI; measured draw is 1-2m. As a DaemonSet the
agent alone parks half a core on every node. Nothing here had ever set
resources, so this was an inherited default rather than a decision.
Only the request changes. Limits stay at the chart default, so a log flood can
still burst to 500m; what shrinks is the reservation the scheduler subtracts
from every node whether or not the process uses it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
jupiter's Crucial P3 Plus OSD is at 87% endurance used, and reaching the
MS-01's only U.2-capable slot means moving the boot drive anyway. Doing the
bare-metal conversion in the same window avoids opening the machine twice and
throws away no work: the osd-ssd PCI mapping that a Proxmox-side swap would
need to be re-pointed at ceases to exist.
Networking uses the v1.12 multi-document config rather than the deprecated
machine.network.interfaces. The docs do not define what happens when one link
is configured by both schemas, so k8s-1 keeps every link in one of them. This
also buys VLANConfig.name, which is free-form: naming the VLAN 30 link ens19
keeps the four v30iot macvlan NADs working unchanged across VM and bare-metal
nodes, so the cluster can stay mixed without pinning those workloads.
Physical NICs are matched by permanent MAC, not driver — both X710 ports bind
i40e here, unlike the single passed-through port k8s-2/k8s-3 see.
cephfs-metadata drops to size 2 / min_size 1 for the duration. At size 3 on
two remaining hosts every PG sits undersized with min_size 2, so one further
OSD loss would block IO on every CephFS mount cluster-wide. This must go back
to size 3 once k8s-1 rejoins.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The sweep restores every discovered Velero schedule, immich's ~180 GiB
library included. At size 2 that is ~360 GiB raw, ~120 GiB per OSD, and
measured on 2026-08-25 it was ~350 of the ~740 GB each drive wrote per
week — ~47% of the endurance budget, against a ~65 GB/day weekday
baseline.
That baseline is itself the result of the 2026-08-18..21 write-reduction
work (#518, #519, #520, CNPG checkpoint tuning, RAM-backed emptyDirs,
paperless data to RBD, CI workspaces to cephfs-ci), which cut per-drive
writes ~70% from ~195 GB/day. With the application tier down, the restore
test is now the single largest consumer of remaining QLC endurance; the
three OSD drives are at 81/82/87% used.
Monthly still exercises every restore path and cuts the sweep's share of
drive wear ~4x, moving per-drive weekly writes from ~740 GB to ~530 GB.
Cadence-only change:
- 0 8 * * 0 -> 0 8 1 * *, keeping the 08:00 UTC slot that clears the
03:15-07:15 daily backup window (see the comment in the manifest).
- ttlSecondsAfterFinished 14 d -> 40 d, so the previous run is still
inspectable when the next one fires.
- Comments and docs that state the cadence updated to match, including
the BLUESTORE_SLOW_OP_ALERT runbook text, which tells the reader to
check whether a stall fell inside the restore-test window.
No day-of-week form is available: Kubernetes parses cron with
robfig/cron's standard parser, whose day-of-week field allows only
`* / , - ?` (no Quartz `#` nth-weekday), and restricting both day fields
ORs them.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The Wetterstation now carries a non-default reporting configuration: min
interval 5s on all ten reportable attributes, and tighter reportable-change
deadbands on temperature, humidity and pressure. None of it is expressible
in configuration.yaml - Zigbee2MQTT has no settings-schema field for
reporting configuration - so it lives only on the device and in Z2M's
database.db. This documents it and how to restore it.
min was 10s against an 8.8s transmit interval. Since min is a hold-off, every
change-triggered report was held past a transmit cycle and landed on the
next, so attributes reported at best every 17.6s and drifted out of phase.
The published stream showed no 8.8s periodicity at all. At min 5 each
attribute reports on its own transmit and the stream carries one publish per
cycle, measured at a mean gap of 8.69s. Publish volume fell from ~631/h to
~445/h because each publish is now a whole cycle rather than a fragment.
The deadbands come from the shared modernExtend helpers, which the WS90
definition composes without overrides. They are anti-chatter values sized for
battery-powered indoor sensors. Temperature was 1.00 C, giving a staircase
that moved about twice an hour; it is now 0.1 C, matching the resolution the
device actually reports. Pressure was 5 kPa - 50 hPa, which real barometric
pressure never traverses, so it only ever updated on the hourly heartbeat
that pressure_trend and weather_condition derive from. Note the same library
configures the identical ZCL attribute with a 5 hPa deadband in its older
reporting.ts helper, so the two code paths disagree by 10x.
Anything that makes Z2M re-run configure on the device reverts all of it, and
a fresh PVC will not have it. The restore commands are written out literally
rather than generated by a shell helper, because the nested quoting through
`kubectl exec -- sh -c` is where this goes wrong; each was executed and
verified as written, including the read-back, and re-applying is a no-op.
No behaviour change from this commit itself - the device was reconfigured at
runtime, this only records it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
#560 claimed a merged episode "surfaces as a single all-zero frame". It
does not, and the difference decides whether a downstream filter is even
possible.
The zeros propagate attribute by attribute through the burst, so the
merged frame carries whatever subset had zeroed when that burst ended.
Across three episodes captured at nanosecond resolution the propagation
happened to complete, which is where the wrong generalisation came from.
Nothing guarantees it. A burst ending mid-propagation publishes a frame
with temperature at zero while humidity and pressure still read normally,
which is a physically consistent measurement - Z2M recomputes dew_point
from the false temperature - and is not separable from a genuine winter
reading.
The zeros also begin inside an otherwise normal transmit cycle, roughly
20ms after a valid reading in the same burst (measured: 27.7ms, 19.8ms,
22.0ms). They occupy a regular reporting slot, so no timing property
distinguishes them either.
Since the merge is last-wins and the zeros arrive at the tail of the
burst, it resolves that burst to the zeros and discards the valid reading
that led it. So debounce trades six bad samples per episode for one, at
the cost of one good sample. That is a bound on the corruption, not a
filter, and the comment now says so.
No behaviour change; the debounce value and device stanza are untouched.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
The value is unchanged and correct; the comment committed alongside it in
#559 was neither accurate nor the right place for most of what it said.
Accuracy. It cited the device's ZCL reporting configuration as the bound,
reading minRepIntval 10 as "the station updates every 10s". minRepIntval
is not a cadence: with maxRepIntval 3600 and a reportable change set, the
ZCL reporting model gives periodic reports at the MAXIMUM interval — once
an hour — plus change-driven reports each held back so it lands no sooner
than 10s after the previous. It is a hold-off on change-triggered reports
and says nothing about the gap between reports of different attributes,
which is what a debounce window sees.
The bound that applies is the documented transmit interval — readings
every 2s, transmitted every 8.8s — against Z2M's documented rule not to
set debounce above the sensor's update interval. Shelly's knowledge base
rounds the same figure to 9s.
It also claimed the window had to exceed 1s because "the recovery burst
straddles a second boundary", inferred from log lines stamped 11:42:11
and 11:42:12. Those are second-resolution timestamps and cannot
distinguish 10ms from 900ms. No lower bound was ever established.
Length. The rest was commit-message material sitting in a config file:
justification for the chosen value, gap-distribution and run-length
measurements, and notes reconciling my own earlier misreadings. Comments
state facts about the system, not the history of arriving at them. What
remains is what the device does, what debounce does to it, and the
constraint on the value — 41 lines down to 13.
Verified before writing: post-debounce frames arrive complete (all 22
fields, no partials) at a settled ~10s cadence.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Two changes to the Wetterstation (Ecowitt WS90, 0xc02cedfffe958f40), both
aimed at the station's recurring zero-drop glitch.
2.13.0 carries zigbee-herdsman-converters#12748, which discards the ZCL
non-value markers (0xffff / 0xff / 0xffffff) the WS90 emits when a reading
is unavailable. Without it those markers are scaled and published as
measurements — the 6553 m/s gust readings in Koenkk/zigbee2mqtt#31048. The
release also recovers the rain rate after a counter reset, which is the
same lifetime-counter dip that packages/wetterstation.yaml compensates for
on the Home Assistant side. Its only breaking change is dropping Node.js 20
for bare-metal installs; the container ships its own runtime. The amd64
manifest was verified pullable before this commit.
debounce: 2 addresses the part 2.13.0 does not fix. Koenkk/zigbee2mqtt#31048
is still open, and the author of #12748 states explicitly that it does not
cover the zero drops: "a zero can be a real reading for these attributes,
only the all-bits-set markers are provably invalid."
The station reports as a burst of seven per-cluster ZCL frames and Z2M
publishes its full cumulative state once per frame, so one device report
becomes seven MQTT messages. During a glitch the zeros appear progressively
across those seven, which is what makes the corruption unrecognisable
downstream: an intermediate frame carrying {"temperature":0,"humidity":92,
"pressure":96.9} is internally consistent (Z2M recomputes dew_point from the
false temperature) and cannot be told apart from a legitimate winter
reading. Merging the burst yields a single frame with the all-zero
signature, which a consumer can reject.
The window is bounded on both sides. Above: the device's own reporting
configuration sets minRepIntval 10 / maxRepIntval 3600 on all seven WS90
clusters (1024/1026/1027/1029 and 0xfc01/0xfc02/0xfc03), so no attribute
repeats inside 10s. Below: the recovery burst straddles a second boundary,
so 1s splits it and emits a partial frame.
Staggering was checked rather than assumed — the 10s floor is per attribute,
and nine attributes report across those clusters, so a trailing-edge timer
could in principle keep resetting and never flush. Over 6h the longest
unbroken chain of sub-2s gaps was 5, bounding worst-case deferral under
~10s.
The device is also absent from the seeded device list, which predates it
joining, so this adds the friendly_name too.
NOTE: this file is seed-only. A running Z2M owns its configuration.yaml on
the PVC, so this does not change the live instance — it only makes a fresh
PVC come up correctly. debounce is requiresRestart, so applying it live
needs the option set on the running instance and a restart; the image bump
supplies the restart.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
From the #426 audit. Tag verified present before bumping.
The kaniko bump that was originally in this branch is dropped. It would
have pinned a new `-debug` image, and debug variants are not to run in
the production cluster. kaniko is archived upstream, so the fix is
migration rather than a version bump; tracked in #552 along with the
`-debug` requirement.
Comments should say what the setting does and what constrains it. The
blocks added in #542, #544, #545 and #547 had grown into incident
write-ups: measurement runs, prior values, how a problem was found,
what a check used to be. That belongs in commit messages and the wiki,
both of which already carry it.
Trimmed, no behaviour change:
cephcluster.yaml 22 lines -> 6 (cephx rotation)
cephfs-ci.yaml 26 lines -> 7 (why size 2)
prometheusrule-ceph.yaml (CephHealthWarn, 43 -> 13;
CephPoolLostRedundancy, 15 -> 7)
The operative facts are kept: which checks are excluded and why they
cannot clear, that POOL_NO_REDUNDANCY reports blocked maintenance and
not only data risk, and that size 1 needs dedicated OSDs.
The unreplicated CI pools introduced in #542 make every OSD on the
cluster permanently un-restartable.
`ceph osd ok-to-stop` refuses while stopping an OSD would take PGs
offline. A size-1 pool puts every PG on exactly one OSD, so the check
fails for all three:
Error EBUSY: unsafe to stop osd(s) at this time
(20 PGs are or would become offline)
bad_become_inactive: 13.6 13.9 ... 14.1c 14.1d
Pools 13 and 14 are cephfs-ci-metadata and cephfs-ci-data0. The size-2
pools are not implicated — they run min_size 1 and appear under
ok_become_degraded, which is allowed.
Rook gates OSD restarts on that check, so this blocks CephX key
rotation, Ceph upgrades, node drains and reboots, and drive
replacement. It surfaced when #545 deadlocked: Rook retried
ok-to-stop against all three OSDs several times a second and could
never succeed, while `ceph -s` reported 217 pgs active+clean
throughout. Nothing is unhealthy; the restarts are simply refused.
The reasoning in #542 was that unreplicated CI data only risks
in-flight pipelines, since every byte is a fresh git clone. That part
holds. What it missed is that the cost is not scoped to the pool: one
unreplicated pool freezes maintenance for the entire cluster.
Most of #542's saving came from keeping CI churn off `cephfs`, whose
metadataPool is size 3 — that survives this change. Only the second-
order gain from dropping the replica is given up, and cephfs-ci-data0
stores 0 B with cephfs-ci-metadata at 182 MiB, so the backfill is
trivial.
size 1 becomes viable again once these pools sit on OSDs of their own,
where the permanently un-stoppable OSD holds nothing but throwaway
data. That is planned with the retired QLC drives.
Alerting follows the same change:
- POOL_NO_REDUNDANCY is no longer excluded from CephHealthWarn. It was
excluded because cephfs-ci was expected to keep it permanently
active; no pool is unreplicated now, so the exclusion would only
hide a real one losing its replicas.
- CephPoolLostRedundancy drops its cephfs-ci exemption for the same
reason, and its description now states the maintenance consequence,
not just the data-loss one.
- The AUTH_INSECURE_* exclusion is reworded. Calling it
"known-accepted" reads as a decision that the risk is fine; it is a
kernel-blocked remediation (aes256k over the CSI mount path needs
kernel 7.0+, nodes run 6.18).
Refs #542, #545, #527
Ceph v19.2.6 ships the fix for CVE-2025-30156, a CephX authentication
bypass: AES-128-CBC service tickets carry no HMAC and use a hard-coded
IV, so a holder of any low-privilege key can bit-flip a ticket into
cluster-admin in linear time. Upgrading the binaries does not resolve
it — the keys themselves must be rotated to the aes256k cipher.
The cluster is mid-procedure. auth_allowed_ciphers (aes, aes256k),
auth_preferred_cipher (aes256k) and auth_service_cipher (aes256k) are
already set, and the rotating service keys were wiped, but no actual
key rotation has happened: every entity in status.cephx is still
keyGeneration 1 with keyType aes, created under 19.2.3.
Rook automates daemon-key rotation but it is opt-in and defaults to
Disabled, so spec.security.cephx was left empty and nothing rotated.
Rook v1.20.6 and Ceph v19.2.6 are both past the version floor the
feature requires.
Rotating daemon keys clears AUTH_INSECURE_SERVICE_KEY_TYPE, the only
one of the six new checks at ERR severity. That is the operationally
urgent part: Rook skips CephFS and RGW reconciliation entirely while
health is HEALTH_ERR — which is what deadlocked the mds/rgw rollout in
issue #527 — and the check is presently held down only by a mon-side
mute with a finite TTL. When that mute lapses the cluster returns to
HEALTH_ERR and the reconcile freeze comes back.
CSI keys are deliberately left on aes. aes256k over the CSI mount path
requires a host kernel of 7.0 or newer and these nodes run 6.18, so
`aes` must stay in auth_allowed_ciphers for CSI to authenticate at all.
AUTH_INSECURE_CLIENT_KEY_TYPE, AUTH_INSECURE_KEYS_ALLOWED and
AUTH_INSECURE_KEYS_CREATABLE therefore stay raised at WARN until the
nodes run a kernel that supports it.
Rotation restarts most Ceph daemons. With size 2 pools across 3 OSDs
this should be applied deliberately rather than alongside other churn,
and Ceph should reach HEALTH_OK before anything else touches the
cluster.
Refs #527, #528
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
CephHealthWarn alerted on `ceph_health_status == 1`. It has been FIRING since
at least 2026-08-21T00:26Z and cannot clear: four AUTH_INSECURE_* checks are
permanently active from CVE-2025-30156 (#527) and stay that way until Rook
>=1.20.5 lands. A permanently-firing alert reports nothing -- every Ceph
warning since then has been invisible behind it.
This is a pre-existing gap, not a consequence of the cephfs-ci work, though
that work would have added a second permanent cause (POOL_NO_REDUNDANCY, since
the CI pools are size 1 on purpose).
ceph_health_detail exposes each check as its own series, so the alert now fires
on any check that is NOT known-accepted, and names it. Verified against live
data: 5 checks active, 0 unexpected, so it is quiet now and fires the moment
something genuinely new appears.
Excluding POOL_NO_REDUNDANCY wholesale would give something up: that check is
cluster-wide and does not say WHICH pool, so accepting it for cephfs-ci would
equally hide a production pool dropping to one replica. CephPoolLostRedundancy
restores that. There is no pool-size metric, but bytes_used/stored IS the
replication factor -- verified live as replicapool 2, cephfs-data0 2,
cephfs-metadata 3, cephfs-ci-metadata 1.
Both alerts were tested against live data before committing, in BOTH
directions. The positive control matters as much as the negative one: an early
draft used a >1e9 floor which silently excluded the CI pools entirely, so the
expression could not have matched anything. It looked correct precisely because
it returned no results. The control caught it; the floor is now 1e6.
The floor is not what suppresses the near-empty rgw pools. Their ratios are
9-36 because per-object overhead dominates, so they never match `< 1.5`.
6h on CephHealthWarn is unchanged -- Ceph warns for self-clearing conditions
and paging on those trains people to ignore the alert.
Repoints WOODPECKER_BACKEND_K8S_STORAGE_CLASS at ceph-filesystem-ci, the
dedicated filesystem added in #542 whose pools are both size 1.
Measured 2026-08-21, polling both CephFS pools every 15s:
CI active 1.5 min (6 intervals): data0 143.2 MB metadata 17.2 MB
CI idle 16.0 min (63 intervals): data0 0.0 MB metadata 11.0 MB
CI share of writes: data0 100%, metadata 61%
data0 takes zero bytes across 16 minutes without a pipeline, so its entire
write volume is CI. The 15s cadence is what made this visible: a pipeline
creates, uses and deletes its PVC inside ~2 minutes, so a 5-minute sample
reported no CI pods during bursts CI was causing.
Per pipeline this moves the drive cost from 71.6x2 + 8.2x3 = ~168 MB to
~80 MB, since neither pool is replicated on the new filesystem.
RWX is unchanged and still required: pipeline steps share the workspace PVC
and the k8s backend can schedule them on different nodes, so an RWO volume
fails to mount on the second node. Only the filesystem underneath changes.
Also corrects the justification written into #542 for leaving
ceph-filesystem-ephemeral alone. That commit claimed restore-test.sh handles
"REAL data which must not land on unreplicated pools". That is wrong: its
probe PVCs are as throwaway as a CI workspace -- the authoritative copy is the
backup on Hetzner, and losing a probe just means re-running the test.
The actual reason it cannot move is technical: those probes are snapshot
CLONES, and `ceph fs subvolume snapshot clone` operates within a single
filesystem, so a snapshot taken in `cephfs` cannot be cloned into `cephfs-ci`.
Landing them unreplicated would require a second size-1 data pool inside
`cephfs`; restore-test runs weekly against CI's ~96 pipelines/day, so that is
not worth the complexity.
cephfs-ci verified healthy before this change: PHASE Ready, MDS Running, both
pools reporting size 1.
Woodpecker's Kubernetes backend creates a PVC per pipeline, fills it with a
checkout plus build output, and deletes it when the pipeline ends. Those
workspaces currently live on the shared `cephfs`, so throwaway data is
replicated as if it mattered: 2x in cephfs-data0 and 3x in cephfs-metadata.
Measured 2026-08-21 by polling both pools every 15s. The interval matters --
at 5 minutes a whole pipeline is invisible, because its PVC is created, used
and deleted inside ~2 minutes. Sampling that slowly reported zero CI pods
during bursts CI was causing, which sent this investigation down three wrong
paths before the cadence was fixed.
one pipeline, a single 15s interval: data0 +71.6 MB metadata +8.2 MB
every interval with no CI pod: data0 ~0 metadata ~0
So CI accounts for essentially all CephFS write volume; between pipelines the
metadata pool is quiet at ~4 MB/day. On the shared filesystem one pipeline
costs 71.6x2 + 8.2x3 = ~168 MB of drive writes. On this one it costs ~80 MB.
size 1 is correct here even though it was rejected for `cephfs`. There,
metadataPool stays at 3 because losing it destroys the entire filesystem
rather than the objects on one OSD, and 550 GiB of real data depends on it.
Here every byte is a fresh git clone: total loss means in-flight pipelines
fail and get re-run. Replicating throwaway data was the cost, so it is what
gets removed.
`ceph-filesystem-ephemeral` is deliberately NOT repointed. It has a second
consumer -- velero/restore-test.sh restores REAL data through it for
verification, which must not land on unreplicated pools. A new class also
sidesteps StorageClass.parameters being immutable.
Nothing uses ceph-filesystem-ci yet, so this commit is inert: it provisions
the filesystem and its MDS and changes no existing workload. Repointing the
Woodpecker agent is a separate change, once this is confirmed healthy.
Known consequence: size 1 raises POOL_NO_REDUNDANCY, so cluster health will
warn until that is addressed. Silencing it via mon_warn_on_pool_no_redundancy
is cluster-wide and would also hide a production pool dropping to 1, so it
wants a targeted alert instead -- deliberately left out of this commit rather
than switching the warning off blind.
The MDS is 512Mi/1Gi with no standby, not the 4Gi active+standby that `cephfs`
runs. That figure is driven by immich's cached inode count; a CI workspace is
a few thousand files that vanish with the pipeline, and a second daemon to
protect throwaway work is not worth its memory.
A WAL segment is a fixed 16 MiB file. archive_timeout forces a switch on a
timer, and the switched-out segment is written and archived at its full size
no matter how little real WAL it holds. CNPG defaults to 5min, permitting
288 segments/day per cluster of largely padding.
gf-pg went first as a staged rollout and is now verified: 211 -> 41 MB/hour,
an 81% cut, with archived segments falling from ~12/hour to ~1.5/hour in
step. Two independent signals moving together is what confirms the volume
was padding rather than data, and the measured result matched the ~35
MB/hour predicted beforehand.
Fleet-wide this is worth roughly 18 GB/day of logical writes, which at
size=2 with ~1.27x BlueStore overhead is ~45 GB/day at the drives -- about
14% of the 328 GB/day the three OSD NVMes currently take.
ak-pg gets 15min rather than 30min. It holds credentials, sessions and
enrolment state, and the extra 15min would save only a further 0.3 GB/day,
which does not justify doubling the worst-case loss window on that data.
ha-pg saves least in relative terms: its segments are already 63% full of
real WAL (4.9 GB/day), so the timer is not what drives most of its switches.
Also corrects two comments in ha-pg-cluster.yaml that this work falsified.
wal_compression: the claim that these clusters "were not getting compression"
was wrong -- "on" is pglz, which was already compressing. Switching to zstd
moved the WAL rate not at all (4911/4976 -> 5002 MB/day, by LSN advance over
20min windows). Full-page images genuinely are ~62% of WAL here (61.9%
measured as a steady-state delta, against 62.4% lifetime -- so the migration
did not skew it, which was my first guess and it was wrong). There was simply
no headroom between pglz and zstd on this data. zstd is kept because it is
not worse and costs nothing, but it is not a lever.
checkpoint_timeout: 15min -> 30min likewise did not move WAL. Probable reason
is that a recorder is append-mostly -- a page is dirtied while it fills and
then not touched again, so it pays its full-page image once whatever the
checkpoint interval. Kept, but flagged as unjustified pending a data-file
measurement: this volume takes ~11 GB/day against 4.9 GB/day of WAL, so most
of its traffic is outside what a WAL measurement can see.
Context: drive-endurance work on three QLC NVMe OSDs at 81-87% wear.
A WAL segment is a fixed 16 MiB file. archive_timeout forces a segment
switch on a timer so the archive never trails reality by more than that
interval, and the switched-out segment is written and archived at its full
16 MiB no matter how few bytes of real WAL it holds. CNPG defaults this to
5min, which permits up to 288 segments/day = 4.6 GB/day per cluster.
Measured on gf-pg: the database is 21 MB and generates 4.5 MB/day of actual
WAL, while its RBD volume takes 211 MB/hour -- against 192 MB/hour predicted
from 12 switches of 16 MiB. Essentially every byte written to this volume is
padding, roughly 1100x amplification.
This resolves an anomaly that has been open since the start of the endurance
work: gf-pg appeared to write gigabytes per day for a 21 MB database, and
neither WAL volume nor data changes could account for it. Segment padding
does, exactly.
Applied to gf-pg alone as a staged rollout. It is the lowest-risk cluster
and gives the cleanest signal -- its real WAL is small enough that any change
in volume is unambiguously attributable to this parameter. The same default
affects all seven clusters and is worth an estimated ~24 GB/day of logical
writes fleet-wide, but that only goes ahead once this one is verified.
The cost is RPO. On total loss of the cluster, up to 30min of Grafana state
becomes unrecoverable instead of 5min. That state is dashboards, annotations
and preferences, changing at ~4.5 MB/day, so the window is nearly always
empty. Clusters holding credentials or job state get evaluated separately
rather than inheriting this value by default.
archive_timeout is in CNPG's GlobalDefaultSettings, not its
FixedConfigurationParameters, so it is user-overridable -- verified against
pkg/postgres/configuration.go rather than assumed.
Context: drive-endurance work on three QLC NVMe OSDs at 81-87% wear.
`wal_compression: "on"` resolves to pglz, PostgreSQL's original 2016-era
algorithm. Every CNPG cluster here was set that way, so none of them were
getting the compression actually available to them: all seven builds accept
lz4 and zstd (verified via pg_settings.enumvals on each, including immich's
custom pgvector image and trmnl's PostgreSQL 18).
This matters because of what dominates recorder-style write volume. A page
is written to WAL in full -- all 8 KiB -- on its first modification after a
checkpoint, for torn-page protection. Measured on ha-pg, those full-page
images are 62.4% of WAL bytes. Compressing them is therefore the single
largest lever available on WAL volume, and pglz was the weakest option for
the job.
ha-pg additionally moves checkpoint_timeout 15min -> 30min. Full-page images
are emitted once per page per checkpoint interval, so doubling the interval
roughly halves how often each hot page pays the 8 KiB toll. max_wal_size
stays at 2GB deliberately: it must remain well above what one interval
generates, or checkpoints would trigger on size and the interval change
would do nothing. Recovery replays at most one interval of WAL -- under
200MB at the measured rate, i.e. seconds.
The other six clusters keep checkpoint_timeout at 15min. Their measured
write rates do not justify trading recovery time: gf-pg generates 4.5 MB/day
of WAL and wp-pg 62 MB/day, against ak-pg's 604 MB/day.
full_page_writes stays on everywhere. Disabling it would remove the
overhead entirely but RBD can tear a page across an object boundary, and
the trade is write volume against an unrecoverable database.
Both parameters are sighup-reloadable, so this does not restart any cluster.
Context: drive-endurance work on three QLC NVMe OSDs at 81-87% wear.
Prometheus held 298,236 active series. ~108,000 of them -- over a third -- were
apiserver/etcd `_bucket` histograms. Each fans out to one series per bucket x
verb x resource x scope, so a single metric was 23,810 series on its own. Every
Home Assistant metric combined is ~4,100 for comparison.
That cardinality is the dominant driver of Prometheus write volume (~11 GB/day of
TSDB + WAL, doubled again by Ceph replication) and none of it is observable value
on three nodes: per-bucket apiserver latency quantiles are for clusters with SLAs
and dozens of nodes.
Dropped, all verified to have ZERO rule dependencies by checking each metric
against the live alert and recording rules:
apiserver_request_duration_seconds_bucket rules=0 23,810 series
apiserver_request_body_size_bytes_bucket rules=0 23,200
etcd_request_duration_seconds_bucket rules=0 15,840
apiserver_watch_list_duration_seconds_bucket rules=0 11,538
apiserver_watch_cache_read_wait_seconds_bucket rules=0 8,232
apiserver_response_sizes_bucket rules=0 7,592
apiserver_watch_events_sizes_bucket rules=0 5,220
-------
95,432
KEPT deliberately: apiserver_request_sli_duration_seconds_bucket (12,144 series).
23 recording rules depend on it, including the apiserver availability SLO and the
KubeAPIErrorBudgetBurn burn-rate series. Dropping it would silently break that
alerting -- the manifest says so inline, so a later "tidy up" of the regex does
not remove it by accident.
Only `_bucket` series are dropped. The matching `_count` and `_sum` remain, so
request rates and mean latencies still work; what is lost is per-bucket
quantiles.
etcd_* is included even though kubeEtcd is disabled: those are the apiserver's
own etcd-client metrics on the apiserver endpoint, not a separate etcd scrape.
Expected: ~32% fewer active series, so roughly 11 -> 7 GB/day of Prometheus
writes, ~8 GB/day off the drives once replication is counted. Will verify against
prometheus_tsdb_head_series rather than assume.
Refs #434
Co-Authored-By: Claude Bot <noreply@anthropic.com>
An image reference is not a secret. Encoding it as base64 `data` had two real
costs: no reviewer sees a version change in a diff, and no $imagepolicy marker
can attach to a base64 blob.
The result was a two-minor version skew in the component that performs every
base backup and WAL archive for seven Postgres clusters (#535):
controller plugin-barman-cloud:v0.14.0 <- auto-bumped by Flux
sidecar plugin-barman-cloud-sidecar:v0.12.0 <- invisible, never moved
Not stale pods: ha-pg-1 was created hours ago during the recorder migration and
still received v0.12.0.
Three changes:
1. The Secret now uses stringData with the tag in plaintext, carrying an
$imagepolicy marker. The Secret KIND is kept because the controller reads it
via secretKeyRef; switching to a ConfigMap would need a matching edit to that
reference and diverge further from upstream. stringData is accepted
identically by the API server.
2. ImageRepository + ImagePolicy added for the sidecar image, with the same
filter and 0.x range as the controller, so the two cannot drift apart again.
Only the controller was tracked before.
3. Tag aligned to v0.14.0 to match the controller.
The Secret name carries a kustomize hash suffix from upstream's secretGenerator
but is static here, so editing the value does not change the name and the
deployment's secretKeyRef stays valid — verified in the render, which still shows
the name twice (Secret + reference).
Verified the tag EXISTS before pinning it: pulling
plugin-barman-cloud-sidecar:v0.14.0 succeeds (the pod fails later on a missing
`true` binary in that minimal image, which is the container command, not the
pull). Pinning a non-existent tag would have put all seven Postgres clusters into
ImagePullBackOff.
EXPECTED IMPACT: bumping the sidecar changes every Postgres pod spec, so all
seven CNPG clusters roll. CNPG handles this as a normal rolling restart. Backups
should be confirmed working afterwards — 113 Backup CRs exist today, newest ~3h
old and completed.
Note for future re-imports: upstream ships this Secret as base64 `data` with no
marker, so a wholesale re-import silently reintroduces the skew. The manifest now
says so inline.
Refs #535
Co-Authored-By: Claude Bot <noreply@anthropic.com>
description:"The Ceph cluster has held HEALTH_WARN for six hours, so it is not a self-clearing blip. Get the detail with `kubectl -n rook-ceph exec deploy/rook-ceph-tools -- ceph health detail`."
summary:"Ceph health check {{ $labels.name }} active for 6h"
description:"Ceph health check {{ $labels.name }} has been active for six hours. Only AUTH_INSECURE_* is excluded (kernel-blocked, see #527). BLUESTORE_SLOW_OP_ALERT is sticky for 24h after the last stall and clears itself: check whether the stall fell inside the monthly Velero restore-test window (08:00-14:00Z on the 1st), which is expected on these QLC drives — one outside that window, or a repeat on the same OSD, means check that drive (#557). Detail: `kubectl -n rook-ceph exec deploy/rook-ceph-tools -- ceph health detail`."
- alert:CephPoolLostRedundancy
# Names the pool, which POOL_NO_REDUNDANCY does not.
#
# There is no pool-size metric, but bytes_used/stored IS the
# replication factor. The >1e6 floor drops pools too small to measure
# meaningfully, empty ones included.
#
# No pool is exempt.
expr:|
ceph_pool_bytes_used / ceph_pool_stored < 1.5 and ceph_pool_stored > 1e6
for:30m
labels:
severity:critical
annotations:
summary:"Ceph pool {{ $labels.pool_id }} is running unreplicated"
description:"Pool {{ $labels.pool_id }} has a replication factor below 1.5, meaning a single OSD loss destroys data. No pool is meant to be unreplicated — an unreplicated pool also blocks ALL OSD maintenance cluster-wide, since `ceph osd ok-to-stop` refuses while its PGs would go offline. Check with `kubectl -n rook-ceph exec deploy/rook-ceph-tools -- ceph osd pool ls detail`."
- alert:CephHealthError
# HEALTH_ERR means data availability or redundancy is at risk.
summary:"WordPress MariaDB backup has not succeeded in 26h+"
description:"The wordpress-mariadb-backup CronJob's last successful run is over 26 hours old. Check the newest Job's pod logs in the wordpress namespace: `kubectl -n wordpress get jobs`. The 2026-08-19 failure was `The specified bucket does not exist.` against renner-uno-k8s-mariadb while the endpoint itself probed healthy, so a green HetznerBackupEndpointDown does not clear this."
- alert:WordpressMariadbBackupNeverRan
# The staleness expression above goes blind when the metric is
# absent, which is what happens once the operator recreates the
# CronJob. Without this guard "never backed up" is quieter than
summary:"WordPress MariaDB backup has no recorded successful run"
description:"The wordpress-mariadb-backup CronJob exists but has no lastSuccessfulTime: either it has not completed once since the Backup CR was recreated, or every run since has failed. Check `kubectl -n wordpress get jobs` and that the hetzner-s3-creds ExternalSecret is synced."
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.