chore(rook-ceph): return mon_data_avail_warn to the Ceph default #655
@@ -47,26 +47,27 @@ spec:
|
||||
# (paperless + audiobookshelf + immich + ... all clone at once).
|
||||
cephConfig:
|
||||
mon:
|
||||
# Ceph's 30% default assumes the mon has a filesystem to itself, where
|
||||
# 30% free is a meaningful reserve. Here the mons live on
|
||||
# dataDirHostPath /var/lib/rook — the node's /var, shared with ~29 GB
|
||||
# of containerd image and snapshot storage — and the mon DB itself is
|
||||
# ~106 MB. So the default measures container churn, not Ceph: k8s-2
|
||||
# trips MON_DISK_LOW whenever the image cache fills, and image GC does
|
||||
# not clear it (most of /var/lib/containerd is overlayfs snapshots held
|
||||
# by running containers, which GC cannot reclaim — see #434).
|
||||
# 20% of a 60 GB /var still leaves ~12 GB against a 106 MB database.
|
||||
# mon_data_avail_crit stays at the 5% default, and CephMonDiskLow in
|
||||
# monitoring-rules watches /var directly for the real risk, which is the
|
||||
# node filling rather than the mon growing.
|
||||
# The Ceph default, stated rather than left out. Removing the line would
|
||||
# not restore it: `ceph config` keeps a value that only disappears from
|
||||
# this file, so the old 20 would sit in the mon config database
|
||||
# indefinitely — the same trap the bluestore settings below describe,
|
||||
# and the one that crash-looped an OSD during the network provider
|
||||
# change when public_network survived being deleted here.
|
||||
#
|
||||
# BARE-METAL MIGRATION: revisit this. Give the mons their own volume and
|
||||
# the default 30% becomes meaningful again, at which point this override
|
||||
# should be dropped rather than carried over. It cannot be done on the
|
||||
# current cluster — every StorageClass is Ceph-backed, so a mon PVC
|
||||
# would be circular, and Rook only applies mon.volumeClaimTemplate to
|
||||
# newly created mons, never migrating existing ones.
|
||||
mon_data_avail_warn: "20"
|
||||
# It was 20 because the mons share the node's /var with containerd, and
|
||||
# on the VMs that was ~60 GB: 30% free measured image and snapshot churn
|
||||
# rather than anything about Ceph, so k8s-2 tripped MON_DISK_LOW whenever
|
||||
# the image cache filled and GC could not reclaim it (#434).
|
||||
#
|
||||
# Bare metal removed the premise. /var is now ~931 GB per node at 7-8%
|
||||
# used, so 30% free is a real reserve again and the ~106 MB mon database
|
||||
# is irrelevant against it. Reaching 70% would be a genuine signal about
|
||||
# the node rather than noise about the image cache.
|
||||
#
|
||||
# mon_data_avail_crit stays at the 5% default, and CephMonDiskLow in
|
||||
# monitoring-rules still watches /var directly for the real risk, which
|
||||
# is the node filling rather than the mon growing.
|
||||
mon_data_avail_warn: "30"
|
||||
# Stop compacting the whole RocksDB prefix on every paxos trim.
|
||||
#
|
||||
# Upstream default is true — "Compact a certain prefix (including paxos)
|
||||
|
||||
Reference in New Issue
Block a user