Compare commits
23
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
ed86592978 | ||
|
|
a8c2f79f84 | ||
|
|
9f10ea793d | ||
|
|
bdffe1804b | ||
|
|
da1482e33f | ||
|
|
c6b1aa109b | ||
|
|
2f3d952656 | ||
|
|
0a87f91116 | ||
|
|
c59f0050b3 | ||
|
|
48c46610a6 | ||
|
|
53887dd88f | ||
|
|
c9a10ab015 | ||
|
|
24b2a0178d | ||
|
|
b8061ea05d | ||
|
|
d0bea0dc15 | ||
|
|
8ccf5ac8e5 | ||
|
|
08b2fe7ef6 | ||
|
|
04df5da041 | ||
|
|
e8b217e8a1 | ||
|
|
8c03a6e310 | ||
|
|
1213c771ca | ||
|
|
afbb6c3a95 | ||
|
|
32dc191b18 |
@@ -1,18 +0,0 @@
|
||||
apiVersion: external-secrets.io/v1
|
||||
kind: ExternalSecret
|
||||
metadata:
|
||||
name: barman-cloud-creds
|
||||
namespace: authentik
|
||||
annotations:
|
||||
# Prune-disabled — a standing guard kept from the seed->authentik-KS handoff (barman creds).
|
||||
kustomize.toolkit.fluxcd.io/prune: disabled
|
||||
spec:
|
||||
refreshInterval: 1h
|
||||
secretStoreRef:
|
||||
kind: ClusterSecretStore
|
||||
name: openbao
|
||||
target:
|
||||
name: barman-cloud-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/authentik/barman-creds
|
||||
@@ -15,4 +15,4 @@ spec:
|
||||
name: hetzner-s3-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/authentik/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -27,5 +27,4 @@ resources:
|
||||
- cluster.yaml
|
||||
- objectstore.yaml
|
||||
- scheduled-backup.yaml
|
||||
- barman-creds-externalsecret.yaml
|
||||
- hetzner-creds-externalsecret.yaml
|
||||
|
||||
@@ -1,21 +1,8 @@
|
||||
---
|
||||
# Barman S3 credentials for ha-pg.
|
||||
#
|
||||
# FOLLOW-UP (#397): sourced from seed/paperless/hetzner-creds, which is not where
|
||||
# they belong. woodpecker/hetzner-creds-externalsecret.yaml has the identical
|
||||
# problem and the same note. The values are the same today, so this is correct
|
||||
# but coupled: rotating paperless's Hetzner credentials would silently change
|
||||
# the backup credentials for Home Assistant and Woodpecker too.
|
||||
#
|
||||
# The fix is one dedicated path per consumer (seed/home-assistant/hetzner-creds)
|
||||
# and a one-line change to the `key:` below. Creating it needs an OpenBao write:
|
||||
#
|
||||
# bao kv put homelab/seed/home-assistant/hetzner-creds \
|
||||
# @<(bao kv get -format=json homelab/seed/paperless/hetzner-creds | jq '.data.data')
|
||||
#
|
||||
# Note the mount is `homelab`, so the path is homelab/seed/... — #397 records a
|
||||
# 403 on `bao kv list seed`, which was a wrong-path error rather than a
|
||||
# permissions problem.
|
||||
# One shared path for one shared credential — see the note in
|
||||
# ../paperless/hetzner-creds-externalsecret.yaml.
|
||||
#
|
||||
# The namespace allowlist on the openbao ClusterSecretStore
|
||||
# (infrastructure/post-crds/openbao-clustersecretstore.yaml) must include this
|
||||
@@ -35,4 +22,4 @@ spec:
|
||||
name: hetzner-s3-creds
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/paperless/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -1,18 +0,0 @@
|
||||
apiVersion: external-secrets.io/v1
|
||||
kind: ExternalSecret
|
||||
metadata:
|
||||
name: barman-cloud-creds
|
||||
namespace: immich
|
||||
annotations:
|
||||
# Prune-disabled — a standing guard kept from the seed->immich-KS handoff (barman creds).
|
||||
kustomize.toolkit.fluxcd.io/prune: disabled
|
||||
spec:
|
||||
refreshInterval: 1h
|
||||
secretStoreRef:
|
||||
kind: ClusterSecretStore
|
||||
name: openbao
|
||||
target:
|
||||
name: barman-cloud-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/immich/barman-creds
|
||||
@@ -15,4 +15,4 @@ spec:
|
||||
name: hetzner-s3-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/immich/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -13,6 +13,5 @@ resources:
|
||||
- cluster.yaml
|
||||
- objectstore.yaml
|
||||
- scheduled-backup.yaml
|
||||
- barman-creds-externalsecret.yaml
|
||||
- hetzner-creds-externalsecret.yaml
|
||||
- pvcs.yaml
|
||||
|
||||
@@ -6,6 +6,7 @@ kind: Kustomization
|
||||
resources:
|
||||
- prometheusrule-ceph.yaml
|
||||
- prometheusrule-cilium.yaml
|
||||
- prometheusrule-disk-wear.yaml
|
||||
- prometheusrule-hetzner-backup.yaml
|
||||
- prometheusrule-loki.yaml
|
||||
- prometheusrule-mariadb-backup.yaml
|
||||
@@ -24,4 +25,5 @@ resources:
|
||||
- home-assistant-servicemonitor.yaml
|
||||
- immich-servicemonitor.yaml
|
||||
- loki-servicemonitor.yaml
|
||||
- smartctl-exporter-servicemonitor.yaml
|
||||
- probes-blackbox.yaml
|
||||
|
||||
@@ -0,0 +1,92 @@
|
||||
apiVersion: monitoring.coreos.com/v1
|
||||
kind: PrometheusRule
|
||||
metadata:
|
||||
name: disk-wear
|
||||
namespace: monitoring
|
||||
labels:
|
||||
# kube-prometheus-stack's Prometheus resource selects on this label;
|
||||
# without it the rule is created but never loaded into Prometheus.
|
||||
release: kube-prometheus-stack
|
||||
spec:
|
||||
groups:
|
||||
- name: disk-wear.rules
|
||||
rules:
|
||||
# Wear percentages are self-reported: 100 means the rated endurance is
|
||||
# spent, not that the drive stops. Planning thresholds, not predictions.
|
||||
- alert: NvmeDriveWearHigh
|
||||
# Long `for` because wear is monotonic and cannot flap.
|
||||
expr: smartctl_device_percentage_used >= 80
|
||||
for: 1h
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} is at {{ $value }}% rated wear"
|
||||
description: >-
|
||||
{{ $value }}% of rated write endurance used. Nothing is failing
|
||||
yet. Urgency depends on what the drive carries — the Disk Health
|
||||
dashboard shows the role. Losing an OSD costs a rebalance;
|
||||
EPHEMERAL is /var and rebuilds, apart from the node's etcd member
|
||||
data, which has to be removed and re-added.
|
||||
- alert: NvmeDriveWearCritical
|
||||
expr: smartctl_device_percentage_used >= 95
|
||||
for: 1h
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} is at {{ $value }}% rated wear"
|
||||
description: >-
|
||||
The drive is at or past the end of its rated endurance. It will
|
||||
likely keep working for a while, but it is now operating outside
|
||||
what the manufacturer stands behind, and replacement should be
|
||||
scheduled rather than considered.
|
||||
# Wear is a budget; spare exhaustion is damage.
|
||||
- alert: NvmeDriveSpareExhausted
|
||||
expr: smartctl_device_available_spare <= smartctl_device_available_spare_threshold
|
||||
for: 15m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} has exhausted its spare area"
|
||||
description: >-
|
||||
Available spare has fallen to the manufacturer's threshold. The
|
||||
drive has run out of reserve blocks to remap failures into.
|
||||
Replace it.
|
||||
- alert: NvmeDriveCriticalWarning
|
||||
expr: smartctl_device_critical_warning > 0
|
||||
for: 5m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} reports critical warning {{ $value }}"
|
||||
description: >-
|
||||
The drive has raised its own critical warning flag. Read the
|
||||
detail with `smartctl -a` on the node; the value is a bitfield,
|
||||
not a count.
|
||||
- alert: NvmeDriveMediaErrors
|
||||
# On the increase, not the total: pre-existing errors would otherwise
|
||||
# alert forever. Standing counts are visible on the dashboard only.
|
||||
expr: increase(smartctl_device_media_errors[6h]) > 0
|
||||
for: 5m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} recorded {{ $value }} new media errors"
|
||||
description: >-
|
||||
The drive reported unrecoverable data-integrity errors in the
|
||||
last six hours. A healthy drive never increments this. Check
|
||||
whether Ceph has logged scrub errors on the same node.
|
||||
# The check that the checks are running: no series fires no alert.
|
||||
# Counted against node-exporter's inventory, not a fixed fleet size.
|
||||
- alert: SmartctlExporterIncomplete
|
||||
expr: count(smartctl_device_percentage_used) < count(node_nvme_info) or absent(smartctl_device_percentage_used)
|
||||
for: 30m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "Fewer NVMe drives report SMART than node-exporter can see"
|
||||
description: >-
|
||||
Some drives visible to node-exporter are not reporting SMART, or
|
||||
none are. Either a DaemonSet pod is down or a drive stopped
|
||||
answering — both mean the wear alerts above have stopped watching
|
||||
part of the fleet, which looks identical to everything being
|
||||
fine.
|
||||
@@ -0,0 +1,25 @@
|
||||
apiVersion: monitoring.coreos.com/v1
|
||||
kind: ServiceMonitor
|
||||
metadata:
|
||||
name: smartctl-exporter
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
# kube-prometheus-stack's Prometheus resource selects ServiceMonitors
|
||||
# by this label; without it the resource exists but is never
|
||||
# discovered.
|
||||
release: kube-prometheus-stack
|
||||
spec:
|
||||
selector:
|
||||
matchLabels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
endpoints:
|
||||
# smartctl polls the drives every 60s; scraping faster gains nothing.
|
||||
- port: http-metrics
|
||||
path: /metrics
|
||||
interval: 60s
|
||||
relabelings:
|
||||
# Without this a series carries only the exporter pod's IP, which does
|
||||
# not identify the machine the drive is in.
|
||||
- sourceLabels: [__meta_kubernetes_pod_node_name]
|
||||
targetLabel: node
|
||||
@@ -1,6 +1,6 @@
|
||||
{
|
||||
"annotations": {"list": []},
|
||||
"description": "NVMe throughput, latency and temperature per node. Every panel joins node_disk_* to node_nvme_info and node_uname_info on purpose: device names are NOT stable across nodes (nvme0 is the Kingston system disk on k8s-1 and k8s-3, but the Crucial on k8s-2), so a legend keyed on the device alone compares different hardware. Endurance/wear is deliberately absent — see the note at the bottom and issue #549.",
|
||||
"description": "NVMe health and performance per node. The top row answers 'is anything wrong'; the graphs below answer 'why'. Panels resolve each drive through node_nvme_info and node_uname_info rather than plotting the Linux device name, because NVMe enumeration order is not guaranteed to agree across machines — the same name can be a different drive on the next node. Which drive currently holds which role is in the inventory table, deliberately not in this text. Endurance comes from smartctl_exporter, whose series are labelled by node rather than by the exporter pod's IP — see the note at the bottom for what it still cannot tell you.",
|
||||
"editable": true,
|
||||
"fiscalYearStartMonth": 0,
|
||||
"graphTooltip": 1,
|
||||
@@ -9,7 +9,89 @@
|
||||
"panels": [
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Which physical drive is which, resolved live rather than written down. The OSD column comes from ceph_disk_occupation, so it follows Rook instead of restating a device list that would go stale the next time a drive is swapped.",
|
||||
"description": "Ceph's overall verdict. A HEALTH_WARN is frequently raised by something unrelated to the drives, so read the detail before treating it as a storage problem.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"mappings": [{"options": {"0": {"color": "green", "index": 0, "text": "HEALTH_OK"}, "1": {"color": "orange", "index": 1, "text": "HEALTH_WARN"}, "2": {"color": "red", "index": 2, "text": "HEALTH_ERR"}}, "type": "value"}],
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 1}, {"color": "red", "value": 2}]},
|
||||
"unit": "short"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 4, "w": 5, "x": 0, "y": 0},
|
||||
"id": 10,
|
||||
"options": {"colorMode": "background", "graphMode": "none", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
|
||||
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "ceph_health_status", "legendFormat": "", "refId": "A"}],
|
||||
"title": "Ceph health",
|
||||
"type": "stat"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "OSDs the cluster knows about but which are not up. Should read zero. Counted as a difference against ceph_osd_metadata rather than compared to a fixed number, so adding or removing an OSD does not turn this panel into a false alarm. An OSD that is up but out shows as a Ceph health warning instead — it is a state, not a fault, and it does not belong in a red-or-green box.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"mappings": [],
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "red", "value": 1}]},
|
||||
"unit": "short"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 4, "w": 5, "x": 5, "y": 0},
|
||||
"id": 11,
|
||||
"options": {"colorMode": "background", "graphMode": "none", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
|
||||
"targets": [
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "sum(ceph_osd_metadata) - sum(ceph_osd_up)", "legendFormat": "", "refId": "A"}
|
||||
],
|
||||
"title": "OSDs down",
|
||||
"type": "stat"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Raw Ceph capacity in use. The cluster average is the optimistic number: Ceph stops writing when a single OSD crosses the full ratio, so per-OSD headroom is what actually bites.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"mappings": [],
|
||||
"max": 1,
|
||||
"min": 0,
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.75}, {"color": "red", "value": 0.85}]},
|
||||
"unit": "percentunit"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 4, "w": 5, "x": 10, "y": 0},
|
||||
"id": 12,
|
||||
"options": {"colorMode": "background", "graphMode": "area", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
|
||||
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "ceph_cluster_total_used_bytes / ceph_cluster_total_bytes", "legendFormat": "", "refId": "A"}],
|
||||
"title": "Ceph capacity used",
|
||||
"type": "stat"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Fullest EPHEMERAL volume across the fleet — Talos's /var. Its contents are meant to be disposable: container images, kubelet state and pod scratch all rebuild. Filling it is still a problem, because a node with no room to write stops being useful long before anything is lost, and nothing rebalances /var the way Ceph rebalances a full OSD.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"mappings": [],
|
||||
"max": 1,
|
||||
"min": 0,
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.7}, {"color": "red", "value": 0.85}]},
|
||||
"unit": "percentunit"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 4, "w": 5, "x": 15, "y": 0},
|
||||
"id": 13,
|
||||
"options": {"colorMode": "background", "graphMode": "area", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
|
||||
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "max(1 - node_filesystem_avail_bytes{mountpoint=\"/var\"} / node_filesystem_size_bytes{mountpoint=\"/var\"})", "legendFormat": "", "refId": "A"}],
|
||||
"title": "EPHEMERAL used (worst node)",
|
||||
"type": "stat"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Which physical drive is which, resolved live rather than written down — this table is the answer to 'what is in the machines', so that no panel description has to be. The OSD column is joined from ceph_disk_occupation, so it follows Rook; a drive with no OSD is carrying either the system disk or EPHEMERAL.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
@@ -19,27 +101,121 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 24, "x": 0, "y": 0},
|
||||
"gridPos": {"h": 9, "w": 24, "x": 0, "y": 4},
|
||||
"id": 1,
|
||||
"options": {"cellHeight": "sm", "footer": {"countRows": false, "fields": "", "reducer": ["sum"], "show": false}, "showHeader": true, "sortBy": [{"desc": false, "displayName": "node"}]},
|
||||
"targets": [
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"expr": "node_nvme_info * on (instance) group_left(nodename) node_uname_info",
|
||||
"expr": "(label_replace(node_nvme_info * on (instance) group_left(nodename) node_uname_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (nodename, nvmedev) group_left(ceph_daemon) label_replace(label_replace(ceph_disk_occupation, \"nodename\", \"$1\", \"instance\", \"(.*)\"), \"nvmedev\", \"$1\", \"devices\", \"(nvme[0-9]+)n[0-9]+\")) or (label_replace(node_nvme_info * on (instance) group_left(nodename) node_uname_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") unless on (nodename, nvmedev) label_replace(label_replace(ceph_disk_occupation, \"nodename\", \"$1\", \"instance\", \"(.*)\"), \"nvmedev\", \"$1\", \"devices\", \"(nvme[0-9]+)n[0-9]+\"))",
|
||||
"format": "table",
|
||||
"instant": true,
|
||||
"legendFormat": "",
|
||||
"refId": "A"
|
||||
}
|
||||
],
|
||||
"title": "Drive inventory",
|
||||
"title": "Drive inventory (identity and role)",
|
||||
"transformations": [
|
||||
{
|
||||
"id": "organize",
|
||||
"options": {
|
||||
"excludeByName": {"Time": true, "Value": true, "__name__": true, "cntlid": true, "container": true, "endpoint": true, "instance": true, "job": true, "namespace": true, "pod": true, "service": true, "domainname": true, "machine": true, "release": true, "sysname": true, "version": true, "state": true},
|
||||
"excludeByName": {"Time": true, "Value": true, "__name__": true, "cntlid": true, "container": true, "endpoint": true, "instance": true, "job": true, "namespace": true, "pod": true, "service": true, "domainname": true, "machine": true, "release": true, "sysname": true, "version": true, "state": true, "nvmedev": true},
|
||||
"indexByName": {},
|
||||
"renameByName": {"nodename": "node", "device": "device", "model": "model", "serial": "serial", "firmware_revision": "firmware"}
|
||||
"renameByName": {"nodename": "node", "device": "device", "model": "model", "serial": "serial", "firmware_revision": "firmware", "ceph_daemon": "ceph OSD"}
|
||||
}
|
||||
}
|
||||
],
|
||||
"type": "table"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Rated endurance consumed, worst drive in the fleet. This is the drive's own accounting against what the manufacturer warrants, not a failure prediction — a drive past 100 usually keeps working and starts eating its spare area. Read it for planning; read the SMART table for whether anything is failing now.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"mappings": [],
|
||||
"max": 100,
|
||||
"min": 0,
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 80}, {"color": "red", "value": 95}]},
|
||||
"unit": "percent"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 4, "w": 4, "x": 20, "y": 0},
|
||||
"id": 14,
|
||||
"options": {"colorMode": "background", "graphMode": "area", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
|
||||
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "max(smartctl_device_percentage_used)", "legendFormat": "", "refId": "A"}],
|
||||
"title": "Worst NVMe wear",
|
||||
"type": "stat"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Rated endurance consumed per drive. The line is nearly flat by nature — wear moves on a scale of weeks — so the useful reading is the spread between drives and the slope, not today's value. Joined to smartctl_device for the model name, because the device label alone is not comparable across nodes.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "palette-classic"},
|
||||
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "dashed"}},
|
||||
"mappings": [],
|
||||
"max": 100,
|
||||
"min": 0,
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 80}, {"color": "red", "value": 95}]},
|
||||
"unit": "percent"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 13},
|
||||
"id": 15,
|
||||
"options": {"legend": {"calcs": ["last"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"expr": "smartctl_device_percentage_used * on (node, device) group_left(model_name) smartctl_device",
|
||||
"legendFormat": "{{node}} {{model_name}}",
|
||||
"refId": "A"
|
||||
}
|
||||
],
|
||||
"title": "NVMe wear",
|
||||
"type": "timeseries"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "The failure-now signals, as opposed to the endurance budget above. Spare below its threshold means the drive has run out of blocks to remap defects into; media errors are unrecoverable data-integrity failures and should never increment; the critical warning is a bitfield the drive raises itself. Written bytes is the counter behind the wear percentage, useful for projecting when a drive will reach it.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "thresholds"},
|
||||
"custom": {"align": "auto", "cellOptions": {"type": "auto"}, "inspect": false},
|
||||
"mappings": [],
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "text", "value": null}]}
|
||||
},
|
||||
"overrides": [
|
||||
{"matcher": {"id": "byName", "options": "wear"}, "properties": [{"id": "unit", "value": "percent"}, {"id": "custom.cellOptions", "value": {"type": "color-text"}}, {"id": "thresholds", "value": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 80}, {"color": "red", "value": 95}]}}]},
|
||||
{"matcher": {"id": "byName", "options": "spare"}, "properties": [{"id": "unit", "value": "percent"}]},
|
||||
{"matcher": {"id": "byName", "options": "media errors"}, "properties": [{"id": "custom.cellOptions", "value": {"type": "color-text"}}, {"id": "thresholds", "value": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "red", "value": 1}]}}]},
|
||||
{"matcher": {"id": "byName", "options": "critical warning"}, "properties": [{"id": "custom.cellOptions", "value": {"type": "color-text"}}, {"id": "thresholds", "value": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "red", "value": 1}]}}]},
|
||||
{"matcher": {"id": "byName", "options": "powered on"}, "properties": [{"id": "unit", "value": "s"}]},
|
||||
{"matcher": {"id": "byName", "options": "written"}, "properties": [{"id": "unit", "value": "bytes"}]}
|
||||
]
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 13},
|
||||
"id": 16,
|
||||
"options": {"cellHeight": "sm", "footer": {"countRows": false, "fields": "", "reducer": ["sum"], "show": false}, "showHeader": true, "sortBy": [{"desc": true, "displayName": "wear"}]},
|
||||
"targets": [
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_percentage_used * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "A"},
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_available_spare * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "B"},
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_media_errors * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "C"},
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_critical_warning * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "D"},
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_power_on_seconds * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "E"},
|
||||
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "smartctl_device_bytes_written * on (node, device) group_left(model_name) smartctl_device", "format": "table", "instant": true, "refId": "F"}
|
||||
],
|
||||
"title": "SMART health",
|
||||
"transformations": [
|
||||
{"id": "merge", "options": {}},
|
||||
{
|
||||
"id": "organize",
|
||||
"options": {
|
||||
"excludeByName": {"Time": true, "__name__": true, "container": true, "endpoint": true, "instance": true, "job": true, "namespace": true, "pod": true, "service": true},
|
||||
"indexByName": {},
|
||||
"renameByName": {"node": "node", "device": "device", "model_name": "model", "Value #A": "wear", "Value #B": "spare", "Value #C": "media errors", "Value #D": "critical warning", "Value #E": "powered on", "Value #F": "written"}
|
||||
}
|
||||
}
|
||||
],
|
||||
@@ -58,7 +234,7 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 9},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 22},
|
||||
"id": 2,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -91,7 +267,7 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 9},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 22},
|
||||
"id": 3,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -124,7 +300,7 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 18},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 31},
|
||||
"id": 4,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -162,7 +338,7 @@
|
||||
}
|
||||
]
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 18},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 31},
|
||||
"id": 5,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -184,7 +360,7 @@
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"description": "Composite temperature reported by each controller, read from hwmon in sysfs. This is the one health value available without an admin ioctl, which is why it is the only SMART-adjacent series on this dashboard.",
|
||||
"description": "Composite temperature reported by each controller, read from hwmon in sysfs. This is the one health value available without an admin ioctl, which is why it is the only SMART-adjacent series on this dashboard. The thresholds are generic NVMe limits rather than any particular drive's rating — check the datasheet before treating a crossing as urgent.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "palette-classic"},
|
||||
@@ -195,7 +371,7 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 27},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 40},
|
||||
"id": 6,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -222,7 +398,7 @@
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 27},
|
||||
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 40},
|
||||
"id": 7,
|
||||
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
@@ -244,11 +420,40 @@
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"gridPos": {"h": 8, "w": 24, "x": 0, "y": 36},
|
||||
"description": "EPHEMERAL fill level per node. Growth here is usually container images and pod scratch space rather than anything Ceph does.",
|
||||
"fieldConfig": {
|
||||
"defaults": {
|
||||
"color": {"mode": "palette-classic"},
|
||||
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "dashed"}},
|
||||
"mappings": [],
|
||||
"max": 1,
|
||||
"min": 0,
|
||||
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.7}, {"color": "red", "value": 0.85}]},
|
||||
"unit": "percentunit"
|
||||
},
|
||||
"overrides": []
|
||||
},
|
||||
"gridPos": {"h": 8, "w": 24, "x": 0, "y": 49},
|
||||
"id": 9,
|
||||
"options": {"legend": {"calcs": ["last", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
|
||||
"targets": [
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"expr": "(1 - node_filesystem_avail_bytes{mountpoint=\"/var\"} / node_filesystem_size_bytes{mountpoint=\"/var\"}) * on (instance) group_left(nodename) node_uname_info",
|
||||
"legendFormat": "{{nodename}} /var",
|
||||
"refId": "A"
|
||||
}
|
||||
],
|
||||
"title": "EPHEMERAL usage",
|
||||
"type": "timeseries"
|
||||
},
|
||||
{
|
||||
"datasource": {"type": "prometheus", "uid": "prometheus"},
|
||||
"gridPos": {"h": 11, "w": 24, "x": 0, "y": 57},
|
||||
"id": 8,
|
||||
"options": {
|
||||
"code": {"language": "plaintext", "showLineNumbers": false, "showMiniMap": false},
|
||||
"content": "### What this dashboard cannot tell you\n\n**Endurance is missing.** There is no wear, no written-bytes total, no power-on hours and no media-error count here, because no exporter in this cluster produces them. NVMe reports those over an admin ioctl that needs elevated privileges, and temperature is the only health value the kernel publishes through sysfs. Tracked as **#549** — do not read a healthy dashboard as a healthy drive.\n\n**The three roles are not interchangeable.** Each node carries a Kingston OM8PGP41024Q as the Talos system disk, a Samsung PM983 that Rook claims as the Ceph OSD, and a Crucial P3 that was retired from Ceph and now carries the EPHEMERAL volume. The Crucial drives were replaced *because* they were worn, so the drive with the least endurance left is the one holding container state — and it is the one nothing is watching.\n\n**Device names are not identity.** `nvme0` is the Kingston on k8s-1 and k8s-3 and the Crucial on k8s-2. Every panel here resolves the model through `node_nvme_info` for that reason; a query written against a bare device name compares different hardware and will keep doing so silently.",
|
||||
"content": "### What this dashboard cannot tell you\n\nThese notes are about mechanisms, not about the drives currently fitted. The inventory table above is the live answer to what is in the machines; nothing here restates it, because prose does not get re-read when hardware is swapped.\n\n**Wear is a budget, not a prediction.** The percentage is what the drive reports against its own rated endurance. Drives do not stop at 100 — they usually keep working and start consuming spare blocks — so read it for planning, and read available spare and media errors for whether something is failing now. Those are different questions and the alert rules treat them as such.\n\n**A green top row is not a healthy drive.** Endurance says nothing about the drive that dies of a controller fault tomorrow, and this dashboard cannot see one coming.\n\nCeph keeps its own wear figures for OSDs in the devicehealth module, which is a useful cross-check but covers OSDs only: `kubectl -n rook-ceph exec deploy/rook-ceph-tools -- ceph device ls`. A drive removed from Ceph is purged from that registry and its history goes with it.\n\n**Roles are assigned in configuration, not by device name.** Talos selects the system disk and the EPHEMERAL volume by serial, Rook selects the OSD by `/dev/disk/by-id` path. Two consequences outlive any particular set of drives: a broad selector such as `disk.transport == 'nvme'` matches every drive in the box, with the installer taking the OSD as the failure mode — and a drive retired from Ceph is not necessarily out of service, and putting a worn one on EPHEMERAL is a sensible destination rather than a hazard — that volume is built to be rebuilt. Check the inventory table for what a given drive holds before reading its wear as urgent.\n\n**A dying NVMe here hangs rather than errors.** Talos boots with `nvme_core.io_timeout=4294967295`, so NVMe commands never time out. Expect a stall, not an I/O error, and expect the latency panel to go flat rather than spike.\n\n**Kernel messages are not retained.** Talos kernel logs do not reach Loki — the only log jobs are Kubernetes pods and a systemd-journal from elsewhere. `talosctl -n <node> dmesg` is the only source, it is a ring buffer, and a reboot empties it. An NVMe error from before the last reboot left no trace anywhere.",
|
||||
"mode": "markdown"
|
||||
},
|
||||
"title": "Gaps and caveats",
|
||||
|
||||
@@ -15,6 +15,7 @@ resources:
|
||||
- prometheus-gate-service.yaml
|
||||
- prometheus-gate-ingress.yaml
|
||||
- ci-diagnostics-rbac.yaml
|
||||
- smartctl-exporter.yaml
|
||||
- dashboards/
|
||||
# prometheusrule-garage.yaml lives in ./monitoring-rules/ and is applied by a
|
||||
# separate Flux Kustomization that dependsOn `monitoring` — otherwise the
|
||||
|
||||
@@ -0,0 +1,89 @@
|
||||
# SMART/endurance metrics for every NVMe drive in the fleet (#549).
|
||||
#
|
||||
# Runs privileged: host device access is gated by the container device cgroup,
|
||||
# and Kubernetes offers no per-device allowlist. Narrower settings do not work;
|
||||
# the alternatives that were tried are in the commit history.
|
||||
apiVersion: apps/v1
|
||||
kind: DaemonSet
|
||||
metadata:
|
||||
name: smartctl-exporter
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
spec:
|
||||
selector:
|
||||
matchLabels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
template:
|
||||
metadata:
|
||||
labels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
spec:
|
||||
# Control planes are also the storage nodes here, so the exporter has to
|
||||
# tolerate the control-plane taint or it would cover nothing at all.
|
||||
tolerations:
|
||||
- key: node-role.kubernetes.io/control-plane
|
||||
operator: Exists
|
||||
effect: NoSchedule
|
||||
containers:
|
||||
- name: smartctl-exporter
|
||||
image: quay.io/prometheuscommunity/smartctl-exporter:v0.14.0
|
||||
# No --smartctl.device: the exporter scans and rescans on its own.
|
||||
# Device names are not stable across these machines.
|
||||
args:
|
||||
- --web.listen-address=:9633
|
||||
ports:
|
||||
- name: http-metrics
|
||||
containerPort: 9633
|
||||
protocol: TCP
|
||||
securityContext:
|
||||
runAsUser: 0
|
||||
runAsNonRoot: false
|
||||
privileged: true
|
||||
# The API rejects privileged together with
|
||||
# allowPrivilegeEscalation: false.
|
||||
allowPrivilegeEscalation: true
|
||||
readOnlyRootFilesystem: true
|
||||
volumeMounts:
|
||||
# Not read-only: smartmontools opens NVMe devices read-write.
|
||||
- name: dev
|
||||
mountPath: /dev
|
||||
# Scratch space, because the root filesystem is read-only.
|
||||
- name: tmp
|
||||
mountPath: /tmp
|
||||
resources:
|
||||
requests:
|
||||
cpu: 10m
|
||||
memory: 32Mi
|
||||
limits:
|
||||
memory: 128Mi
|
||||
livenessProbe:
|
||||
httpGet:
|
||||
path: /metrics
|
||||
port: http-metrics
|
||||
initialDelaySeconds: 15
|
||||
periodSeconds: 30
|
||||
volumes:
|
||||
- name: dev
|
||||
hostPath:
|
||||
path: /dev
|
||||
type: Directory
|
||||
- name: tmp
|
||||
emptyDir: {}
|
||||
---
|
||||
apiVersion: v1
|
||||
kind: Service
|
||||
metadata:
|
||||
name: smartctl-exporter
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
spec:
|
||||
clusterIP: None
|
||||
selector:
|
||||
app.kubernetes.io/name: smartctl-exporter
|
||||
ports:
|
||||
- name: http-metrics
|
||||
port: 9633
|
||||
targetPort: http-metrics
|
||||
protocol: TCP
|
||||
@@ -1,18 +0,0 @@
|
||||
apiVersion: external-secrets.io/v1
|
||||
kind: ExternalSecret
|
||||
metadata:
|
||||
name: barman-cloud-creds
|
||||
namespace: paperless
|
||||
annotations:
|
||||
# Prune-disabled — a standing guard kept from the seed->paperless-KS handoff (barman creds).
|
||||
kustomize.toolkit.fluxcd.io/prune: disabled
|
||||
spec:
|
||||
refreshInterval: 1h
|
||||
secretStoreRef:
|
||||
kind: ClusterSecretStore
|
||||
name: openbao
|
||||
target:
|
||||
name: barman-cloud-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/paperless/barman-creds
|
||||
@@ -1,3 +1,9 @@
|
||||
# One Hetzner S3 key, one path, shared by every barman ObjectStore. Separate
|
||||
# per-app paths would not make rotation independent — that needs one Hetzner
|
||||
# key per consumer (#397).
|
||||
#
|
||||
# velero reads the same key from infrastructure/velero-hetzner, which holds it
|
||||
# as a credentials file rather than these three fields.
|
||||
apiVersion: external-secrets.io/v1
|
||||
kind: ExternalSecret
|
||||
metadata:
|
||||
@@ -15,4 +21,4 @@ spec:
|
||||
name: hetzner-s3-creds # keeps the old Secret's name — consumers unchanged
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/paperless/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -20,7 +20,6 @@ resources:
|
||||
- cluster.yaml
|
||||
- objectstore.yaml
|
||||
- scheduled-backup.yaml
|
||||
- barman-creds-externalsecret.yaml
|
||||
- hetzner-creds-externalsecret.yaml
|
||||
- pvcs.yaml
|
||||
configMapGenerator:
|
||||
|
||||
@@ -12,4 +12,4 @@ spec:
|
||||
name: hetzner-s3-creds
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/trmnl/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -1,11 +1,8 @@
|
||||
---
|
||||
# Barman S3 credentials for wp-pg.
|
||||
#
|
||||
# Sourced from seed/paperless/hetzner-creds, which is not where they belong.
|
||||
# Issue #397 wants woodpecker to own seed/woodpecker/hetzner-creds; creating
|
||||
# that path needs OpenBao write access (`bao kv list seed` → 403 for the
|
||||
# identities available here), so it stays open. The values are identical, so it
|
||||
# is a one-line swap of the `key:` below once the path exists.
|
||||
# One shared path for one shared credential — see the note in
|
||||
# ../paperless/hetzner-creds-externalsecret.yaml.
|
||||
#
|
||||
# The namespace allowlist on the openbao ClusterSecretStore
|
||||
# (infrastructure/post-crds/openbao-clustersecretstore.yaml) must include this
|
||||
@@ -24,4 +21,4 @@ spec:
|
||||
name: hetzner-s3-creds
|
||||
dataFrom:
|
||||
- extract:
|
||||
key: seed/paperless/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -36,11 +36,9 @@ spec:
|
||||
target:
|
||||
name: hetzner-s3-creds
|
||||
dataFrom:
|
||||
# Reuses the paperless copy of the shared Hetzner S3 credentials (identical
|
||||
# ACCESS_KEY_ID / ACCESS_SECRET_KEY / REGION) to avoid seeding a new OpenBao
|
||||
# path for this migration — same approach woodpecker took. FOLLOW-UP: give
|
||||
# wordpress its own seed/wordpress/hetzner-creds path once OpenBao can be
|
||||
# written, and repoint this here (the value is the same, so it's a drop-in
|
||||
# swap).
|
||||
# One shared path for one shared credential. There is a single Hetzner S3
|
||||
# key behind all of these — see the note in
|
||||
# ../paperless/hetzner-creds-externalsecret.yaml for why per-app paths were
|
||||
# the wrong shape and what would have to change for them to be right.
|
||||
- extract:
|
||||
key: seed/paperless/hetzner-creds
|
||||
key: infrastructure/hetzner-s3
|
||||
|
||||
@@ -5,52 +5,24 @@ machine:
|
||||
- k8s-3.srv.renner.uno
|
||||
- k8s.renner.uno
|
||||
- 10.2.40.60
|
||||
# Install from the Image Factory metal installer, not the stock
|
||||
# ghcr.io/siderolabs/installer that `talosctl gen config` defaults to.
|
||||
# Extensions live in the installer image, so with the stock one the schematic
|
||||
# is only ever a property of the boot media and nothing lands on disk —
|
||||
# `talosctl get extensions` returns empty on a node installed that way.
|
||||
# Image Factory metal installer, NOT the stock ghcr.io/siderolabs/installer
|
||||
# that `talosctl gen config` defaults to. Extensions live in the installer
|
||||
# image; install with the stock one and nothing lands on disk —
|
||||
# `talosctl get extensions` comes back empty.
|
||||
#
|
||||
# What the schematic carries, and why each matters here:
|
||||
# The schematic carries intel-ucode, thunderbolt and i915, and sets
|
||||
# net.ifnames=1, which is what the per-node VLAN parents match against.
|
||||
# Changing which extensions are present means a new schematic hash and a
|
||||
# reinstall or upgrade, not an edit here.
|
||||
#
|
||||
# siderolabs/intel-ucode CPU microcode. On a VM the hypervisor supplied
|
||||
# it; on bare metal nothing does except the BIOS.
|
||||
# siderolabs/thunderbolt Inert until machine.kernel.modules asks for
|
||||
# thunderbolt/thunderbolt_net. Present so enabling
|
||||
# the MS-01 mesh later needs neither a new image
|
||||
# nor a reinstall — which is exactly the property
|
||||
# lost by installing without it.
|
||||
# siderolabs/i915 Intel GPU microcode and kernel modules for the
|
||||
# Alder Lake-P Iris Xe in the MS-01. No workload
|
||||
# requests /dev/dri today; it is here for the same
|
||||
# reason as thunderbolt, so that wanting hardware
|
||||
# transcoding later is a config change rather than
|
||||
# another rolling upgrade of every node.
|
||||
# Read only at install and upgrade time — editing this does nothing to a
|
||||
# running node. The tag must match the version being upgraded to, or the
|
||||
# upgrade is a downgrade. Talos only tests migration between adjacent minor
|
||||
# releases: take the latest patch of each intermediate minor rather than
|
||||
# skipping one.
|
||||
#
|
||||
# Not included, and why, so the absences are not mistaken for oversights:
|
||||
# the X710 (i40e) and I226 (igc) NICs need no firmware extension —
|
||||
# intel-ice-firmware covers E810/ice only. mei is a prerequisite for Intel
|
||||
# Arc discrete GPUs, of which there are none. iscsi-tools, nvme-cli and
|
||||
# util-linux-tools have no consumer: storage is Ceph RBD, and device health
|
||||
# is reported by Ceph itself rather than a node-level exporter.
|
||||
#
|
||||
# 0f6fb8bd… is the bare-metal schematic: same net.ifnames=1 as the Proxmox
|
||||
# one (the predictable interface names the per-node VLAN parents match
|
||||
# against), minus qemu-guest-agent. It supersedes a21cec8f…, which was
|
||||
# identical but without i915 — see RUNBOOK-cold-rebuild.md.
|
||||
#
|
||||
# Only read at install and upgrade time. Changing it here does nothing to a
|
||||
# running node until that node is upgraded. Bump the tag with the Talos
|
||||
# version — it must match the running version, or the upgrade is a downgrade.
|
||||
#
|
||||
# Upgrades follow the documented path: migration is only tested between
|
||||
# adjacent minor releases, so go to the latest patch of each intermediate
|
||||
# minor rather than skipping. 1.12.11 -> 1.13.9 satisfies that — one minor
|
||||
# step from the last 1.12 patch, no intermediate needed.
|
||||
#
|
||||
# Kubernetes is a separate decision and is not forced by this. Talos 1.13
|
||||
# supports Kubernetes 1.36, 1.35, 1.34, 1.33, 1.32 and 1.31, so the cluster
|
||||
# stays on 1.35.2 until `talosctl upgrade-k8s` moves it deliberately.
|
||||
# The Kubernetes version is a separate decision, moved by
|
||||
# `talosctl upgrade-k8s`.
|
||||
install:
|
||||
image: factory.talos.dev/metal-installer/0f6fb8bd8bb53013e9743b7c7b099d96fb9c32fd2464ced32693c2dc0ea5feb9:v1.13.9
|
||||
features:
|
||||
@@ -74,20 +46,13 @@ machine:
|
||||
nodeIP:
|
||||
validSubnets:
|
||||
- 10.2.40.0/24
|
||||
# Lower the image GC thresholds from the kubelet defaults (85/80) to
|
||||
# bound containerd's image cache, which is the largest single consumer
|
||||
# of /var. Spegel P2P pull-through softens the re-pull cost when GC'd
|
||||
# images are needed back.
|
||||
# Lower than the kubelet defaults (85/80) to bound containerd's image
|
||||
# cache, the largest single consumer of /var.
|
||||
#
|
||||
# These thresholds do NOT control whether Ceph's mon reports
|
||||
# MON_DISK_LOW, and must not be tuned for that. Measured on k8s-2:
|
||||
# image GC frees only the content store (~8.6 GB), while the bulk of
|
||||
# /var/lib/containerd is ~20 GB of overlayfs snapshots — unpacked
|
||||
# layers shared with running containers, which GC cannot reclaim.
|
||||
# Dropping high to 60 deleted 28 images and moved free space by 0.02
|
||||
# percentage points. The mon's own data is ~106 MB; its 30%-free
|
||||
# warning is measuring a filesystem it merely shares, so the lever for
|
||||
# it is elsewhere (mon volume, /var size, or mon_data_avail_warn).
|
||||
# Do NOT tune these to clear Ceph's MON_DISK_LOW. Image GC reclaims only
|
||||
# the content store; the bulk of /var/lib/containerd is overlayfs
|
||||
# snapshots shared with running containers, which GC cannot touch. The
|
||||
# lever for the mon warning is elsewhere.
|
||||
extraConfig:
|
||||
imageGCHighThresholdPercent: 70
|
||||
imageGCLowThresholdPercent: 60
|
||||
|
||||
@@ -1,55 +1,25 @@
|
||||
# k8s-1 runs Talos directly on jupiter's MS-01 hardware; k8s-2 and k8s-3 are
|
||||
# still Proxmox VMs. Every machine-specific selector below differs from theirs
|
||||
# for that reason: there are no virtio NICs, no PCI-passthrough layer, and all
|
||||
# four physical NICs and all three NVMe drives are visible to Talos at once.
|
||||
#
|
||||
# Networking uses the v1.12 multi-document config rather than the deprecated
|
||||
# machine.network.interfaces. That is deliberate: the docs do not define what
|
||||
# happens when the same link is configured by both schemas, so this file keeps
|
||||
# every link in one schema instead of straddling them.
|
||||
# Networking uses the multi-document config, not the deprecated
|
||||
# machine.network.interfaces. Keep every link in one schema: the docs do not
|
||||
# define what happens when both configure the same link.
|
||||
machine:
|
||||
network:
|
||||
hostname: k8s-1
|
||||
sysctls:
|
||||
# ens19 (VLAN 30, v30iot) is LINK ONLY — no host addressing. It exists as
|
||||
# the macvlan parent for the v30iot pod attachments
|
||||
# (matter/otbr/shelly-manager/music-assistant), whose children do their own
|
||||
# DHCP on that L2. Host addresses were never needed and are actively
|
||||
# harmful: a connected 10.2.30.0/24 route makes node replies to IoT-subnet
|
||||
# clients bypass the UDM, which breaks every UDM-DNATed flow (hairpin NAT:
|
||||
# un-translated SYN-ACK -> client kernel RST, verified live 2026-07-23).
|
||||
# This disables v6 entirely on that link, including link-local.
|
||||
# ens19 (VLAN 30, v30iot) is LINK ONLY — it is the macvlan parent for the
|
||||
# v30iot pod attachments and must never get host addressing. A connected
|
||||
# 10.2.30.0/24 route makes node replies bypass the UDM and breaks every
|
||||
# DNATed flow.
|
||||
net.ipv6.conf.ens19.disable_ipv6: "1"
|
||||
# Same argument, applied to the physical ports rather than a VLAN child.
|
||||
#
|
||||
# enp2s0f0np0 is nothing but the trunk parent for mgmt0 and ens19, and
|
||||
# enp87s0 is unused. Both sit on the untagged fallback network, where by
|
||||
# design nothing is supposed to run — and both were autoconfiguring
|
||||
# themselves from its router advertisements: an fd00::/64 ULA each, plus
|
||||
# an IPv6 default route each.
|
||||
#
|
||||
# The result was four IPv6 default routes per node at identical priority
|
||||
# 1024 — mgmt0, enp2s0f0np0, enp87s0 and lo — of which only mgmt0 has a
|
||||
# globally routable source address. With nothing to break the tie,
|
||||
# outbound IPv6 mostly left through an interface whose only usable source
|
||||
# was a ULA, so the cluster had no IPv6 egress at all while IPv4 worked
|
||||
# normally. It surfaced as two NetBird probes reporting the proxies down
|
||||
# for 30 hours; the proxies were fine and answered IPv6 in 13 ms from
|
||||
# outside.
|
||||
#
|
||||
# Verified on k8s-1 before rolling to the others: disabling v6 on a VLAN
|
||||
# parent leaves the VLAN child alone. mgmt0 kept its global address and
|
||||
# its fd40:: address, Ceph did not notice, and every failing probe
|
||||
# recovered on the next scrape.
|
||||
# These two sit on the untagged fallback network, where nothing may run.
|
||||
# Left enabled they autoconfigure a ULA and an IPv6 default route from its
|
||||
# RAs, which ties with mgmt0's and costs the cluster IPv6 egress.
|
||||
# Disabling v6 on a VLAN parent does not affect the VLAN child.
|
||||
net.ipv6.conf.enp2s0f0np0.disable_ipv6: "1"
|
||||
net.ipv6.conf.enp87s0.disable_ipv6: "1"
|
||||
install:
|
||||
# Three NVMe drives are ordinary block devices to Talos here: the Kingston
|
||||
# OM8PGP41024Q-A0 system disk, the Samsung PM983 that Rook claims as the
|
||||
# Ceph OSD, and the retired Crucial P3 that carries EPHEMERAL (see the
|
||||
# VolumeConfig below). Every one of them is selected by serial. Nothing in
|
||||
# this file may use a broad selector: `disk.transport == 'nvme'` matches all
|
||||
# three, and the failure mode is Talos taking the OSD drive.
|
||||
# Select disks by serial only. A broad selector such as
|
||||
# `disk.transport == 'nvme'` matches every drive in the machine, and the
|
||||
# failure mode is the installer taking the Ceph OSD drive.
|
||||
diskSelector:
|
||||
serial: 50026B7382B48B86
|
||||
certSANs:
|
||||
@@ -59,15 +29,10 @@ machine:
|
||||
cluster:
|
||||
allowSchedulingOnControlPlanes: true
|
||||
---
|
||||
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk.
|
||||
#
|
||||
# That drive is at 87% of its rated endurance and was this node's Ceph OSD until
|
||||
# the PM983 replaced it. /var is exactly the right role for a disk in that
|
||||
# state: containerd's image and snapshot store, pod logs and the Ceph mon store
|
||||
# are all reconstructible, so the drive is consumable here in a way it is not as
|
||||
# an OSD. It also gives /var ~931 GB instead of the 64 GB the VM-era zvol had,
|
||||
# which is the constraint that makes k8s-2 and k8s-3 trip DiskPressure whenever
|
||||
# they absorb another node's pods.
|
||||
# EPHEMERAL (/var) goes on the retired Ceph OSD drive, deliberately: its
|
||||
# contents are reconstructible, so a worn disk is consumable here in a way it
|
||||
# is not as an OSD. Note /var/lib/etcd lives here too, which is the one thing
|
||||
# on the volume that is not free to lose.
|
||||
#
|
||||
# THIS ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
|
||||
# solely when the volume does not yet exist; a config applied after EPHEMERAL
|
||||
@@ -75,8 +40,8 @@ cluster:
|
||||
# requires wiping the disk and booting install media again.
|
||||
#
|
||||
# Matched by serial deliberately. `disk.transport == 'nvme' && !system_disk`
|
||||
# would match the PM983 as well, and losing that coin flip means Talos formats
|
||||
# the OSD drive.
|
||||
# still matches the OSD drive, and losing that coin flip means Talos formats
|
||||
# it.
|
||||
apiVersion: v1alpha1
|
||||
kind: VolumeConfig
|
||||
name: EPHEMERAL
|
||||
@@ -86,30 +51,25 @@ provisioning:
|
||||
minSize: 50GiB
|
||||
grow: true
|
||||
---
|
||||
# X710 port 0 carries the switch trunk. It takes no addressing itself — the
|
||||
# port's untagged VLAN is the 192.168.8.0/24 network, which this node has no
|
||||
# business being on — so management and v30iot both ride it as tagged VLANs.
|
||||
# X710 port 0 carries the switch trunk and takes no addressing itself — its
|
||||
# untagged VLAN is a network this node has no business being on. Management
|
||||
# and v30iot ride it as tagged VLANs.
|
||||
#
|
||||
# Links are addressed by predictable kernel name. Those derive from PCI
|
||||
# topology, not probe order — though not immune: adding the third NVMe
|
||||
# renumbered the buses and moved the unused second I226 from enp89s0 to
|
||||
# enp90s0. Neither name used here was affected.
|
||||
# Links are named by predictable kernel name, which derives from PCI topology
|
||||
# and can still shift when hardware is added.
|
||||
#
|
||||
# LinkAliasConfig would be the better way to pin these, and is worth
|
||||
# reintroducing — but only once it is proven. Aliasing both X710 ports by
|
||||
# permanent MAC and using the aliases as VLAN parents produced a node with no
|
||||
# address on any interface: the aliases were never created, so every document
|
||||
# referencing them did nothing, including the static address on port 1. Verify
|
||||
# any alias-based revision with `talosctl apply-config --mode=try`, which rolls
|
||||
# back on its own, before making it permanent.
|
||||
# LinkAliasConfig would pin these better, but aliasing the X710 ports by MAC
|
||||
# and using the aliases as VLAN parents left the node with no address on any
|
||||
# interface — the aliases were never created and every document referencing
|
||||
# them silently did nothing. Prove any alias-based revision with
|
||||
# `talosctl apply-config --mode=try` first; it rolls back on its own.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Management, VLAN 40. Carries the node IP, etcd, the API and Ceph's public
|
||||
# network. The k8s-1 VM reached 10.2.40.174 over this same physical port via
|
||||
# Proxmox's v40srv VNet (vmbr0.40), so the switch trunks VLAN 40 here.
|
||||
# network.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: mgmt0
|
||||
@@ -117,30 +77,15 @@ vlanID: 40
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Management addressing is DHCP and the lease is NOT reserved anywhere in this
|
||||
# repo — the k8s-{1,2,3}.srv.renner.uno reservations live on the UDM out of band
|
||||
# and opentofu/unifi.tf declares no live resources. The addresses do move under
|
||||
# a running node: k8s-3 went 10.2.40.168 -> .138 mid-flight on 2026-08-26
|
||||
# without its Node object ever re-registering (issue #635).
|
||||
# DHCP, and the lease is not reserved in this repo — reservations live on the
|
||||
# UDM out of band. Addresses do move under a running node.
|
||||
#
|
||||
# kube-apiserver does not follow when that happens. Talos starts it with
|
||||
# `--advertise-address=$(POD_IP)` and no `--endpoint-reconciler-type` override,
|
||||
# so the advertised address is fixed at pod start and the default lease
|
||||
# reconciler goes on renewing the masterlease under the OLD address. Nothing
|
||||
# expires it while the process lives, so `default/kubernetes` keeps handing out
|
||||
# a dead endpoint and the node's live address is never registered at all — 19h
|
||||
# of TargetDown on job="apiserver", a monitoring blind spot on one of three
|
||||
# apiservers, and it cleared only when the static pod restarted.
|
||||
#
|
||||
# So after any node re-IPs, check that
|
||||
# kube-apiserver does not follow a re-IP: it advertises $(POD_IP) fixed at pod
|
||||
# start and the lease reconciler keeps renewing the masterlease under the old
|
||||
# address, so `default/kubernetes` hands out a dead endpoint until the static
|
||||
# pod restarts (#635). After any node re-IPs, check that
|
||||
# `kubectl get endpoints kubernetes -n default` agrees with
|
||||
# `kubectl get nodes -o wide`, and restart the offending node
|
||||
# (`talosctl -n <node> reboot`) if it does not.
|
||||
#
|
||||
# Pinning mgmt0 with a static AddressConfig alongside this document would remove
|
||||
# the trigger, but it needs an address outside the UDM's DHCP pool — which is
|
||||
# not declared in this repo — and §6 of RUNBOOK-baremetal-conversion.md applies:
|
||||
# prove it with `talosctl apply-config --mode=try` before making it permanent.
|
||||
# `kubectl get nodes -o wide` and reboot the node if it does not.
|
||||
apiVersion: v1alpha1
|
||||
kind: DHCPv4Config
|
||||
name: mgmt0
|
||||
@@ -152,10 +97,8 @@ kind: Layer2VIPConfig
|
||||
name: 10.2.40.60
|
||||
link: mgmt0
|
||||
---
|
||||
# Named ens19 on purpose. The four v30iot macvlan NADs hard-code
|
||||
# `master: ens19`, and k8s-2/k8s-3 still present the VLAN as a virtio NIC of
|
||||
# that name. VLANConfig.name is free-form, so keeping it lets one set of NADs
|
||||
# serve both VM and bare-metal nodes for as long as the cluster is mixed.
|
||||
# Named ens19 on purpose: the v30iot macvlan NADs hard-code `master: ens19`.
|
||||
# VLANConfig.name is free-form, so renaming this link means editing them too.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: ens19
|
||||
@@ -163,19 +106,13 @@ vlanID: 30
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Dedicated Ceph cluster network on X710 port 1, VLAN 49 / 10.99.0.0/29,
|
||||
# untagged on the wire. Carries OSD<->OSD replication and nothing else.
|
||||
# Dedicated Ceph cluster network on X710 port 1, VLAN 49, untagged on the
|
||||
# wire. OSD-to-OSD replication and nothing else.
|
||||
#
|
||||
# The node deliberately holds NO address here. Rook attaches this link to the
|
||||
# OSD pods through a Multus macvlan (infrastructure/rook-ceph-cluster/
|
||||
# san-network-attachment.yaml), and a macvlan parent only has to be up — it
|
||||
# does not need an address of its own for its children to work.
|
||||
#
|
||||
# It used to carry 10.99.0.1/29, because reaching this link required
|
||||
# CephCluster.spec.network.provider: host, and that put every Ceph daemon on
|
||||
# host networking, mons included. Nothing needs it now, and by the rule this
|
||||
# segment is built on — Ceph-internal traffic and nothing else — the node has
|
||||
# no business on it either.
|
||||
# The node holds NO address here on purpose. Rook attaches the link to the OSD
|
||||
# pods through a Multus macvlan, and a macvlan parent only needs to be up.
|
||||
# Giving the node an address would put it on a segment reserved for
|
||||
# Ceph-internal traffic.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f1np1
|
||||
|
||||
@@ -9,20 +9,14 @@ machine:
|
||||
# macvlan parent for the v30iot pod attachments; host addresses on that L2
|
||||
# make node replies bypass the UDM and break every UDM-DNATed flow.
|
||||
net.ipv6.conf.ens19.disable_ipv6: "1"
|
||||
# Same argument for the physical ports: enp2s0f0np0 is only the trunk
|
||||
# parent for mgmt0 and ens19, enp87s0 is unused, and both sit on the
|
||||
# untagged fallback network where nothing is supposed to run. Both were
|
||||
# taking an fd00::/64 and an IPv6 default route from its router
|
||||
# advertisements, leaving four equal-priority default routes per node of
|
||||
# which only mgmt0 has a globally routable source. See k8s-1.yaml for the
|
||||
# full reasoning and how it was verified.
|
||||
# Same for the physical ports on the untagged fallback network: left
|
||||
# enabled they take an IPv6 default route from its RAs and cost the
|
||||
# cluster IPv6 egress.
|
||||
net.ipv6.conf.enp2s0f0np0.disable_ipv6: "1"
|
||||
net.ipv6.conf.enp87s0.disable_ipv6: "1"
|
||||
install:
|
||||
# Three NVMe drives are visible on bare metal. Select the installer target
|
||||
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
|
||||
# order the kernel enumerates them in — Talos and Proxmox do not agree on
|
||||
# that order.
|
||||
# Select the installer target by serial so it cannot land on the OSD drive
|
||||
# or on EPHEMERAL, whatever order the kernel enumerates them in.
|
||||
diskSelector:
|
||||
serial: 50026B7382DA5F6E
|
||||
certSANs:
|
||||
@@ -32,17 +26,15 @@ machine:
|
||||
cluster:
|
||||
allowSchedulingOnControlPlanes: true
|
||||
---
|
||||
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
|
||||
# drive is at 81% of its rated endurance and is finished as an OSD, but
|
||||
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
|
||||
# role. It also gives /var ~931 GB instead of the 64 GB the VM-era zvol had.
|
||||
# EPHEMERAL (/var) goes on the retired Ceph OSD drive, deliberately: its
|
||||
# contents are reconstructible, so a worn disk is consumable in this role.
|
||||
#
|
||||
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
|
||||
# solely when the volume does not yet exist; applied later it is silently
|
||||
# ignored and relocating needs a disk wipe and a boot from install media.
|
||||
#
|
||||
# Matched by serial deliberately: a broad selector such as
|
||||
# `disk.transport == 'nvme' && !system_disk` would match the PM983 as well.
|
||||
# `disk.transport == 'nvme' && !system_disk` still matches the OSD drive.
|
||||
apiVersion: v1alpha1
|
||||
kind: VolumeConfig
|
||||
name: EPHEMERAL
|
||||
@@ -85,9 +77,8 @@ kind: Layer2VIPConfig
|
||||
name: 10.2.40.60
|
||||
link: mgmt0
|
||||
---
|
||||
# Named ens19 on purpose: the four v30iot macvlan NADs hard-code
|
||||
# `master: ens19`, and k8s-3 still presents the VLAN as a virtio NIC of that
|
||||
# name. VLANConfig.name is free-form, so one set of NADs serves both.
|
||||
# Named ens19 on purpose: the v30iot macvlan NADs hard-code `master: ens19`.
|
||||
# VLANConfig.name is free-form, so renaming this link means editing them too.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: ens19
|
||||
@@ -95,18 +86,11 @@ vlanID: 30
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Dedicated Ceph cluster network on X710 port 1, VLAN 49 / 10.99.0.0/29,
|
||||
# untagged on the wire. OSD<->OSD replication only. Not routed off its own
|
||||
# segment and deliberately has no default route.
|
||||
# Dedicated Ceph cluster network on X710 port 1, VLAN 49, untagged on the
|
||||
# wire. OSD-to-OSD replication only, not routed off its own segment.
|
||||
#
|
||||
# The node deliberately holds NO address here. Rook attaches this link to the
|
||||
# OSD pods through a Multus macvlan (infrastructure/rook-ceph-cluster/
|
||||
# san-network-attachment.yaml), and a macvlan parent only has to be up — it
|
||||
# does not need an address of its own for its children to work.
|
||||
#
|
||||
# It used to carry 10.99.0.2/29, because reaching this link required
|
||||
# CephCluster.spec.network.provider: host, which put every Ceph daemon on
|
||||
# host networking, mons included. Nothing needs it now.
|
||||
# The node holds NO address here on purpose. Rook attaches the link to the OSD
|
||||
# pods through a Multus macvlan, and a macvlan parent only needs to be up.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f1np1
|
||||
|
||||
@@ -1,27 +1,18 @@
|
||||
# k8s-3 runs Talos directly on neptune's MS-01 hardware. Structurally identical
|
||||
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
|
||||
# serials and addresses differ. neptune was the last node converted, so all
|
||||
# three control-plane nodes now share this layout and no Proxmox remains.
|
||||
# Structurally identical to k8s-1.yaml — see that file for the reasoning
|
||||
# behind each choice; only the serials and addresses differ.
|
||||
machine:
|
||||
network:
|
||||
hostname: k8s-3
|
||||
sysctls:
|
||||
# v30iot NIC carries no host addressing — see k8s-1.yaml.
|
||||
net.ipv6.conf.ens19.disable_ipv6: "1"
|
||||
# Same argument for the physical ports: enp2s0f0np0 is only the trunk
|
||||
# parent for mgmt0 and ens19, enp87s0 is unused, and both sit on the
|
||||
# untagged fallback network where nothing is supposed to run. Both were
|
||||
# taking an fd00::/64 and an IPv6 default route from its router
|
||||
# advertisements, leaving four equal-priority default routes per node of
|
||||
# which only mgmt0 has a globally routable source. See k8s-1.yaml for the
|
||||
# full reasoning and how it was verified.
|
||||
# Same for the physical ports on the untagged fallback network — see
|
||||
# k8s-1.yaml.
|
||||
net.ipv6.conf.enp2s0f0np0.disable_ipv6: "1"
|
||||
net.ipv6.conf.enp87s0.disable_ipv6: "1"
|
||||
install:
|
||||
# Three NVMe drives are visible on bare metal. Select the installer target
|
||||
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
|
||||
# order the kernel enumerates them in — Talos and Proxmox do not agree on
|
||||
# that order.
|
||||
# Select the installer target by serial so it cannot land on the OSD drive
|
||||
# or on EPHEMERAL, whatever order the kernel enumerates them in.
|
||||
diskSelector:
|
||||
serial: 50026B7382B48B90
|
||||
certSANs:
|
||||
@@ -31,10 +22,8 @@ machine:
|
||||
cluster:
|
||||
allowSchedulingOnControlPlanes: true
|
||||
---
|
||||
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
|
||||
# drive is at 83% of its rated endurance and is finished as an OSD, but
|
||||
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
|
||||
# role. Available spare is still 100% and it reports no media errors.
|
||||
# EPHEMERAL (/var) goes on the retired Ceph OSD drive, deliberately: its
|
||||
# contents are reconstructible, so a worn disk is consumable in this role.
|
||||
#
|
||||
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
|
||||
# solely when the volume does not yet exist; applied later it is silently
|
||||
@@ -81,15 +70,8 @@ vlanID: 30
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Dedicated Ceph cluster network — see k8s-1.yaml.
|
||||
# The node deliberately holds NO address here. Rook attaches this link to the
|
||||
# OSD pods through a Multus macvlan (infrastructure/rook-ceph-cluster/
|
||||
# san-network-attachment.yaml), and a macvlan parent only has to be up — it
|
||||
# does not need an address of its own for its children to work.
|
||||
#
|
||||
# It used to carry 10.99.0.3/29, because reaching this link required
|
||||
# CephCluster.spec.network.provider: host, which put every Ceph daemon on
|
||||
# host networking, mons included. Nothing needs it now.
|
||||
# Dedicated Ceph cluster network — see k8s-1.yaml. The node holds NO address
|
||||
# here on purpose; the link is only a macvlan parent for the OSD pods.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: enp2s0f1np1
|
||||
|
||||
Reference in New Issue
Block a user