First phase of moving the resource-hungry Home Assistant pod off k8s-edge. HA is pinned to edge solely by the USB power meter (FTDI FT230X) it reads via the built-in edl21 integration. This adds an sml2mqtt bridge that will read the meter and publish to the in-cluster Mosquitto broker, so HA can read it over MQTT and stop needing the USB device / the edge node. Shipped DORMANT (replicas: 0): the meter's serial port is a single stream, so sml2mqtt and HA's edl21 cannot both read it. Merging this changes nothing at runtime. The cutover (separate steps) is: disable edl21 -> scale this to 1 -> add HA MQTT sensors reusing the existing entity_ids (preserves long-term-statistics history) -> evict HA from edge. Contents: - sml2mqtt-deployment.yaml: edge-pinned, replicas:0, runs spacemanspiff2007/sml2mqtt:3.6.0 as root (meter dev is root:root 0600; no privileged needed), USB hostPath mount, init container renders the broker password into config.yml from a Secret. - sml2mqtt-config.yaml: v3 config; Wh kept (not kWh) to match edl21 so history is continuous; publishes to mosquitto:1883 as user sml2mqtt. - mosquitto: 4th broker user `sml2mqtt` (publish-only sml2mqtt/#) via a new bootstrap Job + passwd/ACL/env entries. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>