fix: [alert] KubePodCrashLooping (apps) (#408) #410
@@ -112,4 +112,13 @@ spec:
|
||||
txtOwnerId: k8s-homelab
|
||||
policy: sync
|
||||
extraArgs:
|
||||
- --webhook-provider-read-timeout=30s
|
||||
# The UDM's /proxy/network/v2/.../static-dns/ endpoint occasionally takes
|
||||
# just over 30s to answer (128 records). external-dns treats ANY RunOnce
|
||||
# error as fatal (log.Fatalf -> exit 1), so a single slow read crashes the
|
||||
# container and the pod enters CrashLoopBackOff — even though the webhook
|
||||
# sidecar completed the fetch successfully a moment later and only failed
|
||||
# to write the response ("broken pipe", client already gone). 60s gives
|
||||
# ~2x headroom over the observed worst case. Raising this cannot stall the
|
||||
# reconcile loop: external-dns runs RunOnce sequentially, so a slow read
|
||||
# just delays the next cycle past the 1m interval.
|
||||
- --webhook-provider-read-timeout=60s
|
||||
|
||||
Reference in New Issue