fix(home-climate): real room sensors only, repair empty heating panels, readable legends #280

Merged
k.renner merged 1 commits from claude-bot/dash-home-climate into master 2026-07-17 11:20:49 +00:00
1 Commits
Author SHA1 Message Date
claude-bot f248e0cc77 fix(home-climate): real room sensors only, repair empty heating panels, readable legends
- All temperature/humidity panels: replace vendor regexes (shelly.*temp etc.)
  that dragged in device-internal temperatures (pond pump 34C, power meter 60C,
  relay 76C) with explicit allow-lists of verified room sensors
- Add missing sensors: shelly_blu_h_t_7203 (KG Schlafzimmer),
  treppenhaus_eg_bewegungsmelder (EG Treppenhaus), vento humidity sensors,
  Shelly Wall Display (DG Buero)
- OG & DG panel: regex had no og_ alternative and showed only device internals;
  now honest DG-only series + description (OG deliberately has no sensor)
- Heating System / Hot Water panels were empty (domain climate/water_heater
  does not exist in the C measurement) -> use vitocal_250_a_* sensors
- Current-value panels: fixed -6h window so dead sensors (EG Shelly H&T trio,
  DG Meter Pro) disappear instead of showing stale values as live
- Legends: map entity_ids to room names in Flux + displayName, removes the
  '_value xyz' prefix
- Align CO2 thresholds between gauge and history (800/1000/1500)
2026-07-17 00:35:15 +02:00