fix(shelly-manager): firmware endpoint name and bind to the pod addresses #1517

Merged
k.renner merged 2 commits from shelly-manager-net1-no-ra into main 2026-10-28 15:54:06 +00:00
2 Commits
Author SHA1 Message Date
claude-botandClaude Opus 5.5 e6d71ba033 fix(shelly-manager): name the firmware endpoint firmware.shelly-manager.renner.uno
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
App endpoints are <function>.<app>.renner.uno (ftp.paperless.renner.uno,
syncthing.paperless.renner.uno).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-28 16:51:03 +01:00
claude-botandClaude Opus 5.5 1f835e31b6 fix(shelly-manager): bind the app to the pod addresses, not [::]
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was canceled
[::]:8082 also listened on net1. POD_IPS (status.podIPs) lets the app bind
8080/8082/9090 to the pod IPv4 and IPv6 only; ASPNETCORE_URLS falls back
to the pod IPv4 for images that do not read POD_IPS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>