edge-host: E3onCAN — read the E380 meter directly #101

Merged
k.renner merged 1 commits from e380-direct into master 2026-07-02 16:52:16 +00:00
5 changed files with 82 additions and 3 deletions
@@ -41,6 +41,14 @@ edge_open3e_devices:
vx3: { tx: "0x6a1", dpList: "vx3" }
vcmu: { tx: "0x68c" }
# --- E3onCAN: passive E380 energy-meter listener (no bus writes, so it
# coexists with the single open3e instance). The meter broadcasts at
# ~5 Hz; the gap throttles MQTT to one update per DID per interval.
edge_e3oncan_repo: https://github.com/MyHomeMyData/E3onCAN.git
edge_e3oncan_version: 461dcbdf97e8d72d2edb9929c63b39382af6c3a1 # V0.5.2
edge_e3oncan_gap_seconds: 10
edge_e3oncan_mqtt_format: "{device}_{didNumber:04d}_{didName}"
# --- Secrets: define these in inventory/group_vars/edge_host/vault.yml
# (ansible-vault). See README.md for the kubectl one-liners that read the
# current values out of the cluster during migration.
@@ -17,3 +17,9 @@
name: open3e
state: restarted
daemon_reload: true
- name: Restart e3oncan
ansible.builtin.systemd:
name: e3oncan
state: restarted
daemon_reload: true
+31
View File
@@ -152,3 +152,34 @@
enabled: true
state: started
daemon_reload: true
# --- E3onCAN: direct E380 meter reads (passive; per-review decision not
# to trust the VX3's relayed meter values). Same broker user as open3e;
# topics land under the same open3e/ prefix as e380_<did>_<name>.
- name: Check out E3onCAN (pinned)
ansible.builtin.git:
repo: "{{ edge_e3oncan_repo }}"
dest: "{{ edge_base_dir }}/e3oncan/src"
version: "{{ edge_e3oncan_version }}"
notify: Restart e3oncan
- name: Create E3onCAN venv with requirements
ansible.builtin.pip:
requirements: "{{ edge_base_dir }}/e3oncan/src/requirements.txt"
virtualenv: "{{ edge_base_dir }}/e3oncan/venv"
virtualenv_command: python -m venv
notify: Restart e3oncan
- name: Deploy e3oncan systemd unit
ansible.builtin.template:
src: e3oncan.service.j2
dest: /etc/systemd/system/e3oncan.service
mode: "0644"
notify: Restart e3oncan
- name: Enable e3oncan
ansible.builtin.systemd:
name: e3oncan
enabled: true
state: started
daemon_reload: true
@@ -0,0 +1,31 @@
# Managed by ansible (roles/edge-host).
# PASSIVE listener for the E380 energy meter's CANopen broadcasts — no
# writes on the bus, so it may run alongside the (single) open3e
# instance. Reads the meter directly instead of trusting the VX3's
# relayed values.
[Unit]
Description=E3onCAN E380 energy-meter CAN listener (read-only)
BindsTo=sys-subsystem-net-devices-{{ edge_can_interface }}.device
After=sys-subsystem-net-devices-{{ edge_can_interface }}.device network-online.target
Wants=network-online.target
[Service]
User=open3e
EnvironmentFile={{ edge_base_dir }}/open3e/open3e.env
WorkingDirectory={{ edge_base_dir }}/e3oncan
# Journald-friendly (python block-buffers pipes; lost on restarts).
Environment=PYTHONUNBUFFERED=1
ExecStart={{ edge_base_dir }}/e3oncan/venv/bin/python {{ edge_base_dir }}/e3oncan/src/E3onCANcollect.py \
-c {{ edge_can_interface }} \
-dev e380 \
-g {{ edge_e3oncan_gap_seconds }} \
-m {{ edge_mqtt_host }}:{{ edge_mqtt_port }}:{{ edge_open3e_mqtt_topic }} \
-muser {{ edge_open3e_mqtt_user }} \
-mpass ${OPEN3E_MQTT_PASSWORD} \
-mfstr "{{ edge_e3oncan_mqtt_format }}" \
-j
Restart=on-failure
RestartSec=10
[Install]
WantedBy=multi-user.target
@@ -1,4 +1,7 @@
# Managed by ansible (roles/edge-host). Read by open3e.service.
# Full user:password pair as one variable so the unit can pass it as a
# single -muser argument without exposing it in the unit file.
# Managed by ansible (roles/edge-host). Read by open3e.service and
# e3oncan.service.
# Full user:password pair as one variable so the open3e unit can pass it
# as a single -muser argument without exposing it in the unit file;
# e3oncan takes user and password separately (-muser/-mpass).
OPEN3E_MUSER={{ edge_open3e_mqtt_user }}:{{ edge_open3e_mqtt_password }}
OPEN3E_MQTT_PASSWORD={{ edge_open3e_mqtt_password }}