Compare commits

..
Author SHA1 Message Date
issue-fix-bot fdd303d7a0 fix: [alert] KubeContainerWaiting (home-assistant) (#592)
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
2026-08-25 23:47:26 +00:00
7 changed files with 113 additions and 122 deletions
@@ -77,6 +77,21 @@ spec:
# redirects the socket directly to the backend pod instead of sending
# traffic out to the VIP and back (which fails with L2 announcements).
lbExternalClusterIP: true
# VLAN ids whose tagged frames are passed to the stack instead of being
# dropped by Cilium's VLAN filter. Unset, the filter drops every tagged
# frame the datapath sees — which is what strands the v30iot macvlan
# pods on a converted node: there `ens19` (VLAN 30) and `mgmt0`
# (VLAN 40) are VLAN sub-interfaces of the enp2s0f0np0 trunk, so a
# macvlan child's DHCP DISCOVER leaves tagged and dies as
# DROP_VLAN_FILTER. The CNI DHCP daemon reports that as "no buffer
# space available" (a tc drop surfaces to an AF_PACKET sender as
# ENOBUFS, not as a timeout) and the pod sits in ContainerCreating
# forever — issue #592, predicted in RUNBOOK-baremetal-conversion.md.
# Lists only the two VLANs a node terminates; [0] would bypass the
# filter for every id. Takes effect on agent restart.
# Keep in lockstep with vlan-bpf-bypass in
# kubernetes/talos/patches/cilium-cni.yaml and kubernetes/talos/cilium.yaml.
vlanBypass: [30, 40]
cni:
# Multus (kubernetes/infrastructure/multus) runs alongside Cilium and
# writes 00-multus.conf to /etc/cni/net.d so kubelet picks multus
@@ -167,44 +167,37 @@ spec:
# impossible: the OSD is recreated within a reconcile and starts backfilling
# onto the drive being replaced.
#
# All three nodes are bare metal and see three NVMe drives each, so they name
# their OSDs by /dev/disk/by-id path. A bare name would be actively wrong:
# Talos enumerates these machines' drives in a different order than Proxmox
# did, and the kernel name lands on the Kingston SYSTEM disk or on EPHEMERAL
# depending on the boot. Rook would probably decline the system disk for
# carrying partitions, but that is luck rather than intent. The by-id path is
# derived from model and serial and does not depend on enumeration at all.
#
# k8s-3 demonstrated why: it enumerated the Kingston as nvme0n1 on one boot
# and the Crucial as nvme0n1 on the very next one.
# k8s-1 and k8s-2 are bare metal and see three NVMe drives each, so they name
# their OSDs by /dev/disk/by-id path instead. A bare name would be actively
# wrong: Talos enumerates these machines' drives in a different order than
# Proxmox did, and nvme0n1 there is the Kingston SYSTEM disk. Rook would
# probably decline it for carrying partitions, but that is luck rather than
# intent. The by-id path is derived from model and serial and does not depend
# on enumeration at all.
#
# k8s-1 (jupiter)
# 50026B7382B48B86 Kingston — Talos system disk
# 2332E86B749A Crucial — Talos EPHEMERAL (/var)
# S437NX0M400426 PM983 — this OSD
# nvme0n1 50026B7382B48B86 Kingston — Talos system disk
# nvme1n1 2332E86B749A Crucial — Talos EPHEMERAL (/var)
# nvme2n1 S437NX0M400426 PM983 — this OSD
#
# k8s-2 (saturn)
# 50026B7382DA5F6E Kingston — Talos system disk
# 2332E86B74BC Crucial — Talos EPHEMERAL (/var)
# S437NX0M403161 PM983 — this OSD
#
# k8s-3 (neptune)
# 50026B7382B48B90 Kingston — Talos system disk
# 2326E6E8E67D Crucial — Talos EPHEMERAL (/var)
# S437NF0M501176 PM983 — this OSD
# nvme0n1 50026B7382DA5F6E Kingston — Talos system disk
# nvme1n1 2332E86B74BC Crucial — Talos EPHEMERAL (/var)
# nvme2n1 S437NX0M403161 PM983 — this OSD
storage:
useAllNodes: false
useAllDevices: false
nodes:
# k8s-3 is absent while neptune's OSD drive is swapped and the node is
# converted to bare metal. RE-ADD IT once the PM983 is in and the node has
# rejoined, naming the device by /dev/disk/by-id as the other two do —
# bare metal sees three NVMe drives and the bare name is not the OSD.
- name: k8s-1
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M400426
- name: k8s-2
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M403161
- name: k8s-3
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NF0M501176
config:
osdsPerDevice: "1"
# Storage layer must never be evicted by kubelet under node pressure
@@ -5,24 +5,31 @@ metadata:
namespace: rook-ceph
spec:
failureDomain: host
# size 3. This pool sat at 2 while the OSDs were Crucial P3 QLC drives: with
# 3 OSDs on 3 hosts, size=3 put every write on every drive, so per-drive write
# volume equalled total cluster write volume and all three wore at an
# identical rate (measured 2026-08-19: 80/82/87% endurance used, ~0.13
# points/day, all three projected to exhaust between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that, because the wear was
# correlated by construction rather than independent.
# size 2, NOT 3. With 3 OSDs on 3 hosts, size=3 meant every write landed on
# every drive in the cluster: per-drive write volume equalled total cluster
# write volume, and all three drives wore at an identical rate and would have
# reached end-of-rated-life together (measured 2026-08-19: 80/82/87% endurance
# used, ~0.13 points/day, all three exhausted between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that failure mode, because
# wear-out here is correlated by construction rather than independent.
#
# The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated
# endurance with a far higher write budget, so wear-out is no longer the
# binding constraint and the correlation argument no longer applies.
# size 2 cuts per-drive write volume by a third and desynchronises the wear.
#
# min_size is left at the size-3 default of 2. The explicit min_size 1
# override existed only because Ceph does not lower min_size when size is
# reduced, which would have left the pool 2/2 — where any single OSD down
# min_size 1 is REQUIRED and deliberate. Ceph does not lower min_size when
# size is reduced — it was 2 here, and leaving it would make the pool 2/2,
# where any single OSD down (every rolling node reboot, every OSD restart)
# blocks IO for its PGs and hangs every RBD volume in the cluster.
#
# The trade this accepts: while the pool is degraded (one OSD down), a second
# drive failing loses data, and with all three drives at 80%+ endurance that
# window is not hypothetical. Mitigations that already exist: CNPG barman and
# Velero both ship offsite to Hetzner (opentofu/object_storage.tf), so the
# exposure is the RPO of those backups, not total loss. Keep node reboots
# serialised and wait for HEALTH_OK between them.
replicated:
size: 3
size: 2
parameters:
min_size: "1"
---
apiVersion: storage.k8s.io/v1
kind: StorageClass
@@ -80,26 +87,39 @@ metadata:
name: cephfs
namespace: rook-ceph
spec:
# size 3 with no min_size override. This pool holds ~253 MiB against the data
# pool's 280 GiB, and losing it would destroy the whole filesystem rather
# than just the objects on the lost OSD, so it is the last pool that should
# ever run thin.
# TEMPORARY — RESTORE TO size 3 / no min_size OVERRIDE ONCE SATURN AND
# NEPTUNE HAVE BOTH BEEN CONVERTED TO BARE METAL. It stays at 2/1 across all
# three conversions rather than being toggled per node: each change
# re-replicates the pool, and the window reopens with the next node anyway.
#
# It drops to 2/1 whenever one of the three hosts is out for longer than a
# reboot. size 3 on two remaining hosts leaves every PG undersized at two
# copies with min_size 2, so a single further OSD loss falls below min_size
# and blocks IO on every CephFS mount cluster-wide. At 2/1 the same two
# copies are active+clean instead, and a further loss degrades rather than
# blocks. See RUNBOOK-baremetal-conversion.md.
# The standing trade for this pool is size 3: it holds ~253 MiB against the
# data pool's 280 GiB, so it contributes nothing measurable to drive wear —
# the entire reason data0 dropped to 2 — while losing it would destroy the
# whole filesystem, not just the objects on the lost OSD. Paying 3x on a
# quarter of a gigabyte to keep that intact is the right trade in steady
# state.
#
# It does not hold while one of three hosts is out. size 3 on two remaining
# hosts leaves every PG undersized at two copies with min_size 2, so a single
# further OSD loss drops the pool below min_size and blocks IO on every
# CephFS mount cluster-wide. At 2/1 the same two copies are active+clean
# instead, and a further loss degrades rather than blocks — availability
# bought at the cost of accepting writes onto a single copy while degraded.
#
# See RUNBOOK-baremetal-conversion.md.
metadataPool:
replicated:
size: 3
size: 2
parameters:
min_size: "1"
dataPools:
- name: data0
# size 3 for the same reasons as replicapool above — see the comment
# there for why this pool sat at 2 while the Crucials backed the OSDs.
# size 2 / min_size 1 for the same reasons as replicapool above — see
# the comment there for the full rationale and the accepted trade.
replicated:
size: 3
size: 2
parameters:
min_size: "1"
metadataServer:
activeCount: 1
activeStandby: true
+6
View File
@@ -306,6 +306,12 @@ data:
# Specifies the ratio (0.0-1.0] of total system memory to use for dynamic
# sizing of the TCP CT, non-TCP CT, NAT and policy BPF maps.
bpf-map-dynamic-size-ratio: "0.0025"
# VLAN ids whose tagged frames bypass the eBPF datapath rather than being
# dropped by the VLAN filter. 30 (v30iot, the macvlan parent) and 40 (mgmt)
# are VLAN sub-interfaces of the trunk on a bare-metal node. Keep in lockstep
# with patches/cilium-cni.yaml and values.bpf.vlanBypass in
# kubernetes/infrastructure/cilium/helmrelease.yaml.
vlan-bpf-bypass: "30,40"
# bpf-policy-map-max specifies the maximum number of entries in endpoint
# policy map (per endpoint). Keep in lockstep with patches/cilium-cni.yaml and
# values.bpf.policyMapMax in kubernetes/infrastructure/cilium/helmrelease.yaml.
+7
View File
@@ -324,6 +324,13 @@ cluster:
# Specifies the ratio (0.0-1.0] of total system memory to use for dynamic
# sizing of the TCP CT, non-TCP CT, NAT and policy BPF maps.
bpf-map-dynamic-size-ratio: "0.0025"
# VLAN ids whose tagged frames bypass the eBPF datapath rather than being
# dropped by the VLAN filter. 30 (v30iot, the macvlan parent) and 40 (mgmt)
# are VLAN sub-interfaces of the trunk on a bare-metal node, so without this
# a cold rebuild comes up with the v30iot macvlan pods unable to DHCP. Keep
# in lockstep with kubernetes/talos/cilium.yaml and values.bpf.vlanBypass in
# kubernetes/infrastructure/cilium/helmrelease.yaml.
vlan-bpf-bypass: "30,40"
# bpf-policy-map-max specifies the maximum number of entries in endpoint
# policy map (per endpoint). Keep in lockstep with values.bpf.policyMapMax
# in kubernetes/infrastructure/cilium/helmrelease.yaml, and with the third
+2 -1
View File
@@ -1,6 +1,7 @@
# k8s-2 runs Talos directly on saturn's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials, MACs and addresses differ.
# serials, MACs and addresses differ. k8s-3 is still a Proxmox VM and keeps the
# VM-era layout until neptune is converted.
machine:
network:
hostname: k8s-2
+18 -69
View File
@@ -1,82 +1,31 @@
# k8s-3 runs Talos directly on neptune's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials and addresses differ. neptune was the last node converted, so all
# three control-plane nodes now share this layout and no Proxmox remains.
machine:
network:
hostname: k8s-3
# Shared control-plane VIP — see k8s-1.yaml for the busPath rationale.
interfaces:
- deviceSelector:
busPath: "0000:06:12.0"
dhcp: true
vip:
ip: 10.2.40.60
# v30iot: link only, no host addressing — see k8s-1.yaml.
- deviceSelector:
busPath: "0000:06:13.0"
dhcp: false
# See k8s-1.yaml for context on the dedicated Ceph cluster network.
- deviceSelector:
driver: i40e
addresses:
- 10.99.0.3/29
mtu: 9000
sysctls:
# v30iot NIC carries no host addressing — see k8s-1.yaml.
net.ipv6.conf.ens19.disable_ipv6: "1"
install:
# Three NVMe drives are visible on bare metal. Select the installer target
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
# order the kernel enumerates them in — Talos and Proxmox do not agree on
# that order.
diskSelector:
serial: 50026B7382B48B90
disk: /dev/vda
certSANs:
- k8s-3.srv.renner.uno
nodeLabels:
topology.kubernetes.io/zone: neptune
cluster:
allowSchedulingOnControlPlanes: true
---
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
# drive is at 83% of its rated endurance and is finished as an OSD, but
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
# role. Available spare is still 100% and it reports no media errors.
#
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
# solely when the volume does not yet exist; applied later it is silently
# ignored and relocating needs a disk wipe and a boot from install media.
#
# Matched by serial deliberately: a broad selector such as
# `disk.transport == 'nvme' && !system_disk` would match the PM983 as well.
apiVersion: v1alpha1
kind: VolumeConfig
name: EPHEMERAL
provisioning:
diskSelector:
match: disk.serial == '2326E6E8E67D'
minSize: 50GiB
grow: true
---
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: VLANConfig
name: mgmt0
vlanID: 40
parent: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: DHCPv4Config
name: mgmt0
---
# Shared control-plane VIP, held by whichever node wins the etcd campaign.
apiVersion: v1alpha1
kind: Layer2VIPConfig
name: 10.2.40.60
link: mgmt0
---
# v30iot: link only, no host addressing — see k8s-1.yaml.
apiVersion: v1alpha1
kind: VLANConfig
name: ens19
vlanID: 30
parent: enp2s0f0np0
up: true
---
# Dedicated Ceph cluster network — see k8s-1.yaml.
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f1np1
up: true
mtu: 9000
addresses:
- address: 10.99.0.3/29