Compare commits

..
Author SHA1 Message Date
claude-botandClaude Opus 5.5 a81650172e feat(open3e): poll buffer target temperature (DID 1799)
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
DID 1799 PrimaryCircuitCurrentTemperatureSetpoint on the HPMU, every
60 s; 127 UDS points. Live read 36.7 degC. S28-59.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-11 14:45:08 +01:00
2 changed files with 4 additions and 5 deletions
+3 -4
View File
@@ -1,9 +1,8 @@
# vitocal-can
Waveshare ESP32-S3-RS485-CAN running open3e-esp32 from the fork
konairius/open3e-esp32, branch `feat/heating-curve-rw` (0.3.0+019bc2c: upstream
0.3.0 with the heating curves 880-883 writable, S28-55, and `POST /api/rawuds`
for raw UDS request sequences behind `rawWriteEnabled`, S28-57), on Vitocal 250-A socket A
konairius/open3e-esp32, branch `feat/heating-curve-rw` (0.3.0+ea30668: upstream
0.3.0 with the heating curves 880-883 writable, S28-55), on Vitocal 250-A socket A
(Klemme 1 = CAN L, Klemme 3 = CAN H, no GND/shield, jumper H1 = NC).
Replaces the `heating-can` stack on edge-1. YouTrack S28-28.
@@ -15,7 +14,7 @@ Replaces the `heating-can` stack on edge-1. YouTrack S28-28.
- `settings.json`: apply with `PUT /api/settings`. No password: the MQTT
password is pushed by mqtt-account-controller.
- `points.json`: apply with `PUT /api/points`. 126 UDS datapoints (30 s; flow limits 1193/1194 300 s;
- `points.json`: apply with `PUT /api/points`. 127 UDS datapoints (30 s; buffer setpoint 1799 60 s; flow limits 1193/1194 300 s;
fixed topics matching the Home Assistant packages), including the 29 One
Base ZigBee slots on 0x6c3 (topics `onebase_<DID:04d>_<didName>`), and 7
E380 frames (10 s). Compact JSON with default fields omitted: the API takes
File diff suppressed because one or more lines are too long