Compare commits

..
Author SHA1 Message Date
issue-fix-bot 1ac0ef89df fix: [alert] KubePodNotReady (home-assistant) (#590)
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
2026-08-25 21:46:31 +00:00
9 changed files with 117 additions and 278 deletions
+29 -82
View File
@@ -37,6 +37,13 @@ all in state that outlived the VM.
`fdisk -l` — blkid labels lie after a rewrite.
- [ ] Physical access. Secure Boot must be turned off (see below), and that is
the one step nothing can do remotely.
- [ ] **VLAN 30 (v30iot) is tagged on the switch port you are moving to.** As a
VM the IoT NIC came from a Proxmox VNet on the host bridge; bare metal
moves it onto the X710 port 0 trunk, and that need not be the same
physical port. Confirm it in the UniFi port profile *before* the window —
switch config is not managed here (`opentofu/unifi.tf` is examples only).
jupiter went in without this check and `ens19` took 434 packets in 155
minutes, wedging every v30iot macvlan pod in `ContainerCreating` (#590).
## 1. Evacuate the OSD
@@ -172,22 +179,12 @@ use the secureboot installer image too. That is a separate project.
## 5. Install
Boot the stick. Maintenance mode DHCPs untagged on every link; on these hosts
that lands on `192.168.8.x`, which is routable from the workstation. It DHCPs on
*every* link, so one machine answers on several addresses at once — they are the
same host, not several hosts. `get disks` on each confirms it.
that lands on `192.168.8.x`, which is routable from the workstation.
Maintenance mode does serve `talosctl get`. `--insecure` is a flag on the
subcommand rather than a global, so it must come *after* `get` — placed before
it, cobra resolves to the legacy `talosctl disks` command and reports
`unknown flag: --insecure`:
```sh
talosctl -n <maintenance-ip> get disks --insecure
talosctl -n <maintenance-ip> get links --insecure
```
Verify serials and MACs here, on the machine itself, against the config about to
be applied.
Maintenance mode is effectively write-only — `talosctl get` has no `--insecure`
and `version` returns "API is not implemented in maintenance mode". You cannot
inspect disks or links before applying. Verify serials and MACs from the host's
PVE beforehand, in step 3.
Build the config from the **live cluster's secrets**, not a fresh
`talosctl gen config`, or the node forms a new cluster instead of joining:
@@ -212,58 +209,13 @@ Strip the generated `HostnameConfig` document — it collides with
against a base with no `inlineManifests` (issue #581). Use only the additive
second document.
Validate:
Validate, then apply:
```sh
talosctl validate --config install.yaml --mode metal
talosctl apply-config --insecure -n <maintenance-ip> --file install.yaml
```
### Install minimal, complete on the running node
Do **not** apply the full per-node config in maintenance mode. A document that
references an interface which does not exist yet hangs the install: the node
sits at `STAGE: Installing` indefinitely with `KUBELET n/a`, `APISERVER n/a`,
and the console scrolling
```
k8s.NodeApplyController: error getting node: nodes "k8s-N" not found
```
That message is a symptom of an install that never finished, not a Kubernetes or
networking fault — the node holds a DHCP address and is reachable throughout. On
saturn the offenders were the `ens19` VLAN document and the sysctl naming it,
`net.ipv6.conf.ens19.disable_ipv6`. Three cold installs hung on it; the identical
config applied cleanly once the node was up. Wiping disks makes no difference —
it is not leftover state.
**Stage 1** — the smallest config that installs and joins, plus `EPHEMERAL`,
which is one-shot (section 7) and so cannot be deferred to stage 2:
```
machine.network.hostname, machine.install.diskSelector, certSANs, nodeLabels
LinkConfig <uplink>
VLANConfig mgmt0
DHCPv4Config mgmt0
VolumeConfig EPHEMERAL
```
```sh
talosctl apply-config --insecure -n <maintenance-ip> --file install-stage1.yaml
```
**Stage 2** — once the node is `Ready` and `talosctl etcd members` lists it,
apply the full config to the running node. `--mode=try` reverts on its own if the
network config is wrong, so it cannot strand the node; re-apply with
`--mode=auto` to persist.
```sh
talosctl -e <node-ip> -n <node-ip> apply-config --mode=try --timeout=3m --file install.yaml
talosctl -e <node-ip> -n <node-ip> apply-config --mode=auto --file install.yaml
```
Both applied without a reboot on saturn. Confirm `ens19`, `mgmt0` and the Ceph
link are up afterwards with `talosctl get links` and `get addresses`.
## 6. The network config will strand the node if it is wrong
Talos stops running default DHCP operators **for the entire machine** as soon as
@@ -374,8 +326,16 @@ talosctl -n <node> etcd members # 3 members
ceph status # 3 mons in quorum, 3 osds
ceph osd tree # OSD under the right zone/host
ceph device ls # PM983 backing the new OSD
talosctl -n <node> read /proc/net/dev # ens19 RX climbing
```
`ens19` is the one thing nothing else here proves. The node joins, etcd and Ceph
all ride VLAN 40, so a node with VLAN 30 missing looks entirely healthy until an
IoT workload happens to land on it. Read `/proc/net/dev` twice a minute apart:
if `ens19` RX does not move while `mgmt0` does, VLAN 30 is not reaching this
port — go back to the pre-check. `node_network_carrier` and `up` prove nothing,
a VLAN subinterface inherits carrier from its parent.
Then undo the window changes: `cephfs-metadata` back to size 3, immich back to
1 replica, and `ceph config set osd osd_mclock_profile balanced` if it was
raised to `high_recovery_ops` to speed the evacuation.
@@ -389,23 +349,10 @@ The retired Crucial leaves a stale entry in `ceph device ls`. Remove it with
cold rebuild is broken independently of this work.
- Manual Woodpecker pipelines are broken (issue #582), so anything gated on
`PIPELINE == "..."` must be run another way.
- Cilium's eBPF datapath drops VLAN-tagged traffic unless `bpf.vlanBypass` is
set. **This happened** — every v30iot macvlan workload on a converted node
stayed in sandbox creation until `vlanBypass: [30]` was added (issue #592).
Only `ens19` is affected, and the reason is worth knowing: Cilium attaches to
devices that carry an address. `cilium-dbg status --verbose` lists `mgmt0`
among its devices but not `ens19`, because `ens19` is deliberately
address-less. Cilium therefore owns `mgmt0` and sees VLAN 40 frames already
untagged by the 8021q layer, while VLAN 30 frames only ever meet the filter
on the shared parent `enp2s0f0np0`, still tagged. Any future address-less
VLAN carrying pod traffic will need the same treatment.
The symptom does not look like a VLAN problem. A tc-layer drop reaches an
AF_PACKET sender as ENOBUFS, so the CNI dhcp plugin reports `no buffer space
available` and `network is down` rather than a DHCP timeout, and the pod sits
in `ContainerCreating` behind `plugin type="macvlan" failed (add): error
calling DHCP.Allocate: no more tries`. Confirm it with
`cilium_drop_count_total{reason=~"VLAN.*"}` per node rather than by reading
the CNI logs, and check `node_network_receive_packets_total{device="ens19"}`
— it reads 0 on an affected node.
- Cilium's eBPF datapath can silently drop VLAN-tagged traffic unless
`bpf.vlanBypass` is set, and `vlan-bpf-bypass` is indeed empty in
`cilium-config`. Worth knowing — but it was *not* what killed jupiter's
`ens19` (#590), so check the packet counters before reaching for it. A VLAN
subinterface's RX counter increments at 8021q demux, upstream of tc-ingress
BPF on `ens19`, so a Cilium drop there still leaves RX high; and a drop on the
shared parent would have starved `mgmt0` too. Both were the other way round.
@@ -25,11 +25,8 @@ spec:
# replaces the former hostNetwork attachment (see
# network-attachment.yaml) so the NODE no longer holds an address
# on the compromised IoT VLAN; MA gets its own leased IoT IP on
# net1 instead. master: ens19 resolves on every k8s-{1,2,3}/edge
# worker, though it is no longer the same kind of device everywhere:
# on the bare-metal control-plane nodes it is a VLAN 30 sub-interface
# of enp2s0f0np0 rather than a NIC, which is why the datapath needs
# bpf.vlanBypass to carry it (issue #592).
# net1 instead. master: ens19 is the v30iot NIC on every k8s-{1,2,3}/edge
# worker.
k8s.v1.cni.cncf.io/networks: music-assistant-iot
spec:
enableServiceLinks: false
@@ -33,24 +33,6 @@ spec:
remediation:
retries: 3
values:
# Roll the agent DaemonSet when cilium-config changes. Cilium reads
# datapath options once, at agent start, and the chart puts no config
# checksum on the pod template — so a changed ConfigMap leaves every agent
# running the previous datapath until something restarts it. Nothing did.
#
# This is not hypothetical. vlan-bpf-bypass reached cilium-config and every
# v30iot macvlan workload stayed broken until the agents were deleted by
# hand, one node at a time (issue #592). policyMapMax has the same
# exposure, and its comment below says "takes effect on agent restart" —
# documentation standing in for automation.
#
# The trade: any cilium-config change now rolls the CNI cluster-wide,
# node by node. That is disruptive-ish, but it is what a datapath change
# already required — the difference is that it now happens on its own
# instead of being forgotten. Reloader is already deployed for exactly
# this pattern; named per-ConfigMap rather than blanket, as elsewhere.
annotations:
configmap.reloader.stakater.com/reload: cilium-config
# Which pod labels feed security-identity computation. Patterns are
# start-anchored regexes; a leading "!" excludes while keeping the default
# set. Woodpecker stamps every step pod with woodpecker-ci.org/task-uuid
@@ -91,36 +73,6 @@ spec:
# kubernetes/talos/cilium.yaml carries a third copy of the same key.
# Nothing enforces any of this; grep bpf-policy-map-max before changing it.
policyMapMax: 65536
# VLAN ids the eBPF datapath is allowed to pass. Without this it drops
# VLAN-tagged frames, accounted as "VLAN traffic disallowed by VLAN
# filter" in cilium_drop_count_total.
#
# 30 is v30iot, the macvlan parent for the shelly-manager, matter-server,
# otbr and music-assistant attachments. On bare metal it is a VLAN
# sub-interface of enp2s0f0np0; inside the former Proxmox guests it was
# an untagged virtio NIC, which is why this was not needed before.
#
# VLAN 40 (mgmt0) is deliberately NOT listed, and the asymmetry is the
# interesting part. Cilium attaches to devices that carry an address —
# `cilium-dbg status --verbose` lists enp87s0, enp2s0f0np0, enp2s0f1np1
# and mgmt0, but NOT ens19. mgmt0 holds the node IP, so Cilium owns it as
# a device and sees frames the 8021q layer has already untagged; nothing
# for a VLAN filter to match. ens19 is deliberately address-less (see
# talos/patches/k8s-1.yaml — host addresses on that L2 make node replies
# bypass the UDM), so Cilium never attaches to it and VLAN 30 frames only
# meet the filter on the shared parent, still tagged.
#
# So the fix belongs on 30 alone. Listing 40 would change nothing, and
# would touch the datapath carrying etcd and the API for no reason.
#
# A tc-layer drop surfaces to an AF_PACKET sender as ENOBUFS, so the
# symptom is the CNI dhcp plugin reporting "no buffer space available"
# rather than a DHCP timeout. See issue #592.
#
# Same three-copy problem as policyMapMax above: vlan-bpf-bypass in
# kubernetes/talos/cilium.yaml and kubernetes/talos/patches/cilium-cni.yaml
# must move with this list. Takes effect on agent restart.
vlanBypass: [30]
# Let pods reach the cluster's own LoadBalancer external IPs; Cilium
# redirects the socket directly to the backend pod instead of sending
# traffic out to the VIP and back (which fails with L2 announcements).
@@ -167,44 +167,34 @@ spec:
# impossible: the OSD is recreated within a reconcile and starts backfilling
# onto the drive being replaced.
#
# All three nodes are bare metal and see three NVMe drives each, so they name
# their OSDs by /dev/disk/by-id path. A bare name would be actively wrong:
# Talos enumerates these machines' drives in a different order than Proxmox
# did, and the kernel name lands on the Kingston SYSTEM disk or on EPHEMERAL
# depending on the boot. Rook would probably decline the system disk for
# nvme0n1 on k8s-2/k8s-3 is the NVMe drive PCI-passed-through from saturn and
# neptune, and is the only block device those guests can see, so a bare device
# name is unambiguous there.
#
# k8s-1 is bare metal and sees three NVMe drives, so it names its OSD by
# /dev/disk/by-id path instead. A bare name would be actively wrong: Talos
# enumerates this machine's drives in a different order than Proxmox did, and
# nvme0n1 here is the Kingston SYSTEM disk. Rook would probably decline it for
# carrying partitions, but that is luck rather than intent. The by-id path is
# derived from model and serial and does not depend on enumeration at all.
#
# k8s-3 demonstrated why: it enumerated the Kingston as nvme0n1 on one boot
# and the Crucial as nvme0n1 on the very next one.
#
# k8s-1 (jupiter)
# 50026B7382B48B86 Kingston — Talos system disk
# 2332E86B749A Crucial — Talos EPHEMERAL (/var)
# S437NX0M400426 PM983 — this OSD
#
# k8s-2 (saturn)
# 50026B7382DA5F6E Kingston — Talos system disk
# 2332E86B74BC Crucial — Talos EPHEMERAL (/var)
# S437NX0M403161 PM983 — this OSD
#
# k8s-3 (neptune)
# 50026B7382B48B90 Kingston — Talos system disk
# 2326E6E8E67D Crucial — Talos EPHEMERAL (/var)
# S437NF0M501176 PM983 — this OSD
# nvme0n1 50026B7382B48B86 Kingston — Talos system disk
# nvme1n1 2332E86B749A Crucial — Talos EPHEMERAL (/var)
# nvme2n1 S437NX0M400426 PM983 — this OSD
storage:
useAllNodes: false
useAllDevices: false
nodes:
# k8s-2 is absent while saturn's OSD drive is swapped and the node is
# converted to bare metal. RE-ADD IT once the PM983 is in and the node has
# rejoined, naming the device by /dev/disk/by-id as k8s-1 does — bare
# metal sees three NVMe drives and the bare name is not the OSD.
- name: k8s-3
devices:
- name: nvme0n1
- name: k8s-1
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M400426
- name: k8s-2
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M403161
- name: k8s-3
devices:
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NF0M501176
config:
osdsPerDevice: "1"
# Storage layer must never be evicted by kubelet under node pressure
@@ -5,24 +5,31 @@ metadata:
namespace: rook-ceph
spec:
failureDomain: host
# size 3. This pool sat at 2 while the OSDs were Crucial P3 QLC drives: with
# 3 OSDs on 3 hosts, size=3 put every write on every drive, so per-drive write
# volume equalled total cluster write volume and all three wore at an
# identical rate (measured 2026-08-19: 80/82/87% endurance used, ~0.13
# points/day, all three projected to exhaust between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that, because the wear was
# correlated by construction rather than independent.
# size 2, NOT 3. With 3 OSDs on 3 hosts, size=3 meant every write landed on
# every drive in the cluster: per-drive write volume equalled total cluster
# write volume, and all three drives wore at an identical rate and would have
# reached end-of-rated-life together (measured 2026-08-19: 80/82/87% endurance
# used, ~0.13 points/day, all three exhausted between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that failure mode, because
# wear-out here is correlated by construction rather than independent.
#
# The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated
# endurance with a far higher write budget, so wear-out is no longer the
# binding constraint and the correlation argument no longer applies.
# size 2 cuts per-drive write volume by a third and desynchronises the wear.
#
# min_size is left at the size-3 default of 2. The explicit min_size 1
# override existed only because Ceph does not lower min_size when size is
# reduced, which would have left the pool 2/2 — where any single OSD down
# min_size 1 is REQUIRED and deliberate. Ceph does not lower min_size when
# size is reduced — it was 2 here, and leaving it would make the pool 2/2,
# where any single OSD down (every rolling node reboot, every OSD restart)
# blocks IO for its PGs and hangs every RBD volume in the cluster.
#
# The trade this accepts: while the pool is degraded (one OSD down), a second
# drive failing loses data, and with all three drives at 80%+ endurance that
# window is not hypothetical. Mitigations that already exist: CNPG barman and
# Velero both ship offsite to Hetzner (opentofu/object_storage.tf), so the
# exposure is the RPO of those backups, not total loss. Keep node reboots
# serialised and wait for HEALTH_OK between them.
replicated:
size: 3
size: 2
parameters:
min_size: "1"
---
apiVersion: storage.k8s.io/v1
kind: StorageClass
@@ -80,26 +87,39 @@ metadata:
name: cephfs
namespace: rook-ceph
spec:
# size 3 with no min_size override. This pool holds ~253 MiB against the data
# pool's 280 GiB, and losing it would destroy the whole filesystem rather
# than just the objects on the lost OSD, so it is the last pool that should
# ever run thin.
# TEMPORARY — RESTORE TO size 3 / no min_size OVERRIDE ONCE SATURN AND
# NEPTUNE HAVE BOTH BEEN CONVERTED TO BARE METAL. It stays at 2/1 across all
# three conversions rather than being toggled per node: each change
# re-replicates the pool, and the window reopens with the next node anyway.
#
# It drops to 2/1 whenever one of the three hosts is out for longer than a
# reboot. size 3 on two remaining hosts leaves every PG undersized at two
# copies with min_size 2, so a single further OSD loss falls below min_size
# and blocks IO on every CephFS mount cluster-wide. At 2/1 the same two
# copies are active+clean instead, and a further loss degrades rather than
# blocks. See RUNBOOK-baremetal-conversion.md.
# The standing trade for this pool is size 3: it holds ~253 MiB against the
# data pool's 280 GiB, so it contributes nothing measurable to drive wear —
# the entire reason data0 dropped to 2 — while losing it would destroy the
# whole filesystem, not just the objects on the lost OSD. Paying 3x on a
# quarter of a gigabyte to keep that intact is the right trade in steady
# state.
#
# It does not hold while one of three hosts is out. size 3 on two remaining
# hosts leaves every PG undersized at two copies with min_size 2, so a single
# further OSD loss drops the pool below min_size and blocks IO on every
# CephFS mount cluster-wide. At 2/1 the same two copies are active+clean
# instead, and a further loss degrades rather than blocks — availability
# bought at the cost of accepting writes onto a single copy while degraded.
#
# See RUNBOOK-baremetal-conversion.md.
metadataPool:
replicated:
size: 3
size: 2
parameters:
min_size: "1"
dataPools:
- name: data0
# size 3 for the same reasons as replicapool above — see the comment
# there for why this pool sat at 2 while the Crucials backed the OSDs.
# size 2 / min_size 1 for the same reasons as replicapool above — see
# the comment there for the full rationale and the accepted trade.
replicated:
size: 3
size: 2
parameters:
min_size: "1"
metadataServer:
activeCount: 1
activeStandby: true
-7
View File
@@ -310,13 +310,6 @@ data:
# policy map (per endpoint). Keep in lockstep with patches/cilium-cni.yaml and
# values.bpf.policyMapMax in kubernetes/infrastructure/cilium/helmrelease.yaml.
bpf-policy-map-max: "65536"
# VLAN ids the eBPF datapath may pass; without this it drops VLAN-tagged
# frames. 30 is v30iot, the macvlan parent for the IoT workloads, and a VLAN
# sub-interface of enp2s0f0np0 on bare metal. VLAN 40 (mgmt0) rides the same
# parent but passes without an entry, so it is deliberately not listed.
# Keep in lockstep with patches/cilium-cni.yaml and values.bpf.vlanBypass in
# kubernetes/infrastructure/cilium/helmrelease.yaml. See issue #592.
vlan-bpf-bypass: "30"
# bpf-policy-stats-map-max specifies the maximum number of entries in global
# policy stats map
bpf-policy-stats-map-max: "65536"
-10
View File
@@ -331,16 +331,6 @@ cluster:
# inline manifest, so a lower value here means a cold rebuild comes up with
# a map that overflows until Flux reconciles.
bpf-policy-map-max: "65536"
# VLAN ids the eBPF datapath may pass; without this it drops
# VLAN-tagged frames. 30 is v30iot, the macvlan parent for the IoT
# workloads, and a VLAN sub-interface of enp2s0f0np0 on bare metal.
# VLAN 40 (mgmt0) rides the same parent but passes without an entry,
# so it is deliberately not listed. Keep in lockstep with
# values.bpf.vlanBypass in kubernetes/infrastructure/cilium/helmrelease.yaml
# and the third copy in kubernetes/talos/cilium.yaml — bootstrap installs
# from this inline manifest, so omitting it here breaks the IoT macvlan
# workloads until Flux reconciles. See issue #592.
vlan-bpf-bypass: "30"
# bpf-policy-stats-map-max specifies the maximum number of entries in global
# policy stats map
bpf-policy-stats-map-max: "65536"
+2 -1
View File
@@ -1,6 +1,7 @@
# k8s-2 runs Talos directly on saturn's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials, MACs and addresses differ.
# serials, MACs and addresses differ. k8s-3 is still a Proxmox VM and keeps the
# VM-era layout until neptune is converted.
machine:
network:
hostname: k8s-2
+18 -69
View File
@@ -1,82 +1,31 @@
# k8s-3 runs Talos directly on neptune's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials and addresses differ. neptune was the last node converted, so all
# three control-plane nodes now share this layout and no Proxmox remains.
machine:
network:
hostname: k8s-3
# Shared control-plane VIP — see k8s-1.yaml for the busPath rationale.
interfaces:
- deviceSelector:
busPath: "0000:06:12.0"
dhcp: true
vip:
ip: 10.2.40.60
# v30iot: link only, no host addressing — see k8s-1.yaml.
- deviceSelector:
busPath: "0000:06:13.0"
dhcp: false
# See k8s-1.yaml for context on the dedicated Ceph cluster network.
- deviceSelector:
driver: i40e
addresses:
- 10.99.0.3/29
mtu: 9000
sysctls:
# v30iot NIC carries no host addressing — see k8s-1.yaml.
net.ipv6.conf.ens19.disable_ipv6: "1"
install:
# Three NVMe drives are visible on bare metal. Select the installer target
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
# order the kernel enumerates them in — Talos and Proxmox do not agree on
# that order.
diskSelector:
serial: 50026B7382B48B90
disk: /dev/vda
certSANs:
- k8s-3.srv.renner.uno
nodeLabels:
topology.kubernetes.io/zone: neptune
cluster:
allowSchedulingOnControlPlanes: true
---
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
# drive is at 83% of its rated endurance and is finished as an OSD, but
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
# role. Available spare is still 100% and it reports no media errors.
#
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
# solely when the volume does not yet exist; applied later it is silently
# ignored and relocating needs a disk wipe and a boot from install media.
#
# Matched by serial deliberately: a broad selector such as
# `disk.transport == 'nvme' && !system_disk` would match the PM983 as well.
apiVersion: v1alpha1
kind: VolumeConfig
name: EPHEMERAL
provisioning:
diskSelector:
match: disk.serial == '2326E6E8E67D'
minSize: 50GiB
grow: true
---
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: VLANConfig
name: mgmt0
vlanID: 40
parent: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: DHCPv4Config
name: mgmt0
---
# Shared control-plane VIP, held by whichever node wins the etcd campaign.
apiVersion: v1alpha1
kind: Layer2VIPConfig
name: 10.2.40.60
link: mgmt0
---
# v30iot: link only, no host addressing — see k8s-1.yaml.
apiVersion: v1alpha1
kind: VLANConfig
name: ens19
vlanID: 30
parent: enp2s0f0np0
up: true
---
# Dedicated Ceph cluster network — see k8s-1.yaml.
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f1np1
up: true
mtu: 9000
addresses:
- address: 10.99.0.3/29