claude-botandClaude Opus 5 d376f318c2 feat(rook-ceph): restore replicapool and cephfs-data0 to size 3
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
These two sat at size 2 because of #434, not because of the conversion. With
three Crucial P3 QLC OSDs on three hosts, size 3 put every write on every
drive, so per-drive write volume equalled cluster write volume and all three
wore at an identical rate — 80/82/87% of rated endurance, projected to exhaust
together between Nov 2026 and Jan 2027. Replication is no defence against that,
because the wear was correlated by construction.

The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated endurance
with a far higher write budget. Wear-out is no longer the binding constraint
and the correlation argument no longer applies, so the pools return to the
durability the cluster is sized for.

The min_size 1 overrides go with them. They existed only because Ceph does not
lower min_size when size is reduced, which would have left the pools 2/2 and
blocked IO on any single OSD going down.

cephfs-metadata's comment loses the clause explaining that data0 sits at 2,
which stops being true here.

cephfs-ci stays at size 2: that pool holds throwaway CI workspaces and is at 2
rather than 1 only because an unreplicated pool makes `ceph osd ok-to-stop`
refuse for every OSD. Unrelated to #434.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-26 02:13:17 +02:00
k.renner bd5bc920d8 Merge pull request 'feat(rook-ceph): restore cephfs-metadata to size 3' (#609) from restore-cephfs-metadata-size into master
Reviewed-on: k.renner/homelab#609
2026-08-26 00:10:37 +00:00
claude-botandClaude Opus 5 b33c482ad3 feat(rook-ceph): restore cephfs-metadata to size 3
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
All three nodes are converted and the cluster is back to three OSDs across
three zones with 217 PGs active+clean, so the conversion window that justified
2/1 on this pool is over.

The min_size override goes with it. It existed only because Ceph does not
lower min_size when size is reduced, so the pool would have been 2/2 while a
host was out. At size 3 the default min_size of 2 is what the pool wants.

The comment loses its TEMPORARY banner and now states the standing rationale
and the condition under which the pool degrades to two copies.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-26 02:08:38 +02:00
k.renner 0f68a1b344 Merge pull request 'feat(rook-ceph): re-add neptune's OSD on the PM983' (#605) from ceph-readd-neptune into master
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#605
2026-08-25 23:45:52 +00:00
k.renner bd6e101bfb Merge pull request 'feat(k8s-3): bare-metal config for neptune' (#604) from k8s-3-baremetal into master
Reviewed-on: k.renner/homelab#604
2026-08-25 23:45:38 +00:00
claude-botandClaude Opus 5 1306d2ad89 feat(k8s-3): bare-metal config for neptune
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
neptune now runs Talos directly, so k8s-3 moves from the VM-era layout to the
multi-document form k8s-1 and k8s-2 already use. The old config selected
interfaces by busPath against virtio NICs and installed to /dev/vda; neither
exists on bare metal.

Disks are selected by serial rather than kernel name. That is not defensive
styling: Talos enumerated this machine's drives differently than Proxmox did,
and differently again between two consecutive boots — nvme0n1 was the Kingston
on one boot and the Crucial on the next. A device-name reference would have
installed onto the wrong drive.

  nvme  50026B7382B48B90  Kingston  system disk
  nvme  2326E6E8E67D      Crucial   EPHEMERAL, 83% of rated endurance
  nvme  S437NF0M501176    PM983     OSD, 3% used

Serials, interface names and drive health were read from the machine itself —
the Kingston and Crucial off the running Proxmox host before the wipe, and
confirmed again from Talos maintenance mode.

k8s-2.yaml loses the sentence claiming k8s-3 is still a Proxmox VM. No Proxmox
remains in the homelab.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-26 01:43:15 +02:00
3 changed files with 98 additions and 68 deletions
@@ -5,31 +5,24 @@ metadata:
namespace: rook-ceph
spec:
failureDomain: host
# size 2, NOT 3. With 3 OSDs on 3 hosts, size=3 meant every write landed on
# every drive in the cluster: per-drive write volume equalled total cluster
# write volume, and all three drives wore at an identical rate and would have
# reached end-of-rated-life together (measured 2026-08-19: 80/82/87% endurance
# used, ~0.13 points/day, all three exhausted between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that failure mode, because
# wear-out here is correlated by construction rather than independent.
# size 3. This pool sat at 2 while the OSDs were Crucial P3 QLC drives: with
# 3 OSDs on 3 hosts, size=3 put every write on every drive, so per-drive write
# volume equalled total cluster write volume and all three wore at an
# identical rate (measured 2026-08-19: 80/82/87% endurance used, ~0.13
# points/day, all three projected to exhaust between Nov 2026 and Jan 2027 —
# see #434). Replication does not protect against that, because the wear was
# correlated by construction rather than independent.
#
# size 2 cuts per-drive write volume by a third and desynchronises the wear.
# The OSDs are Samsung PM983 enterprise drives now, at 2-3% of rated
# endurance with a far higher write budget, so wear-out is no longer the
# binding constraint and the correlation argument no longer applies.
#
# min_size 1 is REQUIRED and deliberate. Ceph does not lower min_size when
# size is reduced — it was 2 here, and leaving it would make the pool 2/2,
# where any single OSD down (every rolling node reboot, every OSD restart)
# min_size is left at the size-3 default of 2. The explicit min_size 1
# override existed only because Ceph does not lower min_size when size is
# reduced, which would have left the pool 2/2 — where any single OSD down
# blocks IO for its PGs and hangs every RBD volume in the cluster.
#
# The trade this accepts: while the pool is degraded (one OSD down), a second
# drive failing loses data, and with all three drives at 80%+ endurance that
# window is not hypothetical. Mitigations that already exist: CNPG barman and
# Velero both ship offsite to Hetzner (opentofu/object_storage.tf), so the
# exposure is the RPO of those backups, not total loss. Keep node reboots
# serialised and wait for HEALTH_OK between them.
replicated:
size: 2
parameters:
min_size: "1"
size: 3
---
apiVersion: storage.k8s.io/v1
kind: StorageClass
@@ -87,39 +80,26 @@ metadata:
name: cephfs
namespace: rook-ceph
spec:
# TEMPORARY — RESTORE TO size 3 / no min_size OVERRIDE ONCE SATURN AND
# NEPTUNE HAVE BOTH BEEN CONVERTED TO BARE METAL. It stays at 2/1 across all
# three conversions rather than being toggled per node: each change
# re-replicates the pool, and the window reopens with the next node anyway.
# size 3 with no min_size override. This pool holds ~253 MiB against the data
# pool's 280 GiB, and losing it would destroy the whole filesystem rather
# than just the objects on the lost OSD, so it is the last pool that should
# ever run thin.
#
# The standing trade for this pool is size 3: it holds ~253 MiB against the
# data pool's 280 GiB, so it contributes nothing measurable to drive wear —
# the entire reason data0 dropped to 2 — while losing it would destroy the
# whole filesystem, not just the objects on the lost OSD. Paying 3x on a
# quarter of a gigabyte to keep that intact is the right trade in steady
# state.
#
# It does not hold while one of three hosts is out. size 3 on two remaining
# hosts leaves every PG undersized at two copies with min_size 2, so a single
# further OSD loss drops the pool below min_size and blocks IO on every
# CephFS mount cluster-wide. At 2/1 the same two copies are active+clean
# instead, and a further loss degrades rather than blocks — availability
# bought at the cost of accepting writes onto a single copy while degraded.
#
# See RUNBOOK-baremetal-conversion.md.
# It drops to 2/1 whenever one of the three hosts is out for longer than a
# reboot. size 3 on two remaining hosts leaves every PG undersized at two
# copies with min_size 2, so a single further OSD loss falls below min_size
# and blocks IO on every CephFS mount cluster-wide. At 2/1 the same two
# copies are active+clean instead, and a further loss degrades rather than
# blocks. See RUNBOOK-baremetal-conversion.md.
metadataPool:
replicated:
size: 2
parameters:
min_size: "1"
size: 3
dataPools:
- name: data0
# size 2 / min_size 1 for the same reasons as replicapool above — see
# the comment there for the full rationale and the accepted trade.
# size 3 for the same reasons as replicapool above — see the comment
# there for why this pool sat at 2 while the Crucials backed the OSDs.
replicated:
size: 2
parameters:
min_size: "1"
size: 3
metadataServer:
activeCount: 1
activeStandby: true
+1 -2
View File
@@ -1,7 +1,6 @@
# k8s-2 runs Talos directly on saturn's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials, MACs and addresses differ. k8s-3 is still a Proxmox VM and keeps the
# VM-era layout until neptune is converted.
# serials, MACs and addresses differ.
machine:
network:
hostname: k8s-2
+69 -18
View File
@@ -1,31 +1,82 @@
# k8s-3 runs Talos directly on neptune's MS-01 hardware. Structurally identical
# to k8s-1.yaml — see that file for the reasoning behind each choice; only the
# serials and addresses differ. neptune was the last node converted, so all
# three control-plane nodes now share this layout and no Proxmox remains.
machine:
network:
hostname: k8s-3
# Shared control-plane VIP — see k8s-1.yaml for the busPath rationale.
interfaces:
- deviceSelector:
busPath: "0000:06:12.0"
dhcp: true
vip:
ip: 10.2.40.60
# v30iot: link only, no host addressing — see k8s-1.yaml.
- deviceSelector:
busPath: "0000:06:13.0"
dhcp: false
# See k8s-1.yaml for context on the dedicated Ceph cluster network.
- deviceSelector:
driver: i40e
addresses:
- 10.99.0.3/29
mtu: 9000
sysctls:
# v30iot NIC carries no host addressing — see k8s-1.yaml.
net.ipv6.conf.ens19.disable_ipv6: "1"
install:
disk: /dev/vda
# Three NVMe drives are visible on bare metal. Select the installer target
# by serial so it cannot land on the OSD drive or on EPHEMERAL, whatever
# order the kernel enumerates them in — Talos and Proxmox do not agree on
# that order.
diskSelector:
serial: 50026B7382B48B90
certSANs:
- k8s-3.srv.renner.uno
nodeLabels:
topology.kubernetes.io/zone: neptune
cluster:
allowSchedulingOnControlPlanes: true
---
# EPHEMERAL (/var) goes on the retired Crucial P3, not the system disk. That
# drive is at 83% of its rated endurance and is finished as an OSD, but
# everything EPHEMERAL holds is reconstructible, so it is consumable in this
# role. Available spare is still 100% and it reports no media errors.
#
# ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
# solely when the volume does not yet exist; applied later it is silently
# ignored and relocating needs a disk wipe and a boot from install media.
#
# Matched by serial deliberately: a broad selector such as
# `disk.transport == 'nvme' && !system_disk` would match the PM983 as well.
apiVersion: v1alpha1
kind: VolumeConfig
name: EPHEMERAL
provisioning:
diskSelector:
match: disk.serial == '2326E6E8E67D'
minSize: 50GiB
grow: true
---
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: VLANConfig
name: mgmt0
vlanID: 40
parent: enp2s0f0np0
up: true
---
apiVersion: v1alpha1
kind: DHCPv4Config
name: mgmt0
---
# Shared control-plane VIP, held by whichever node wins the etcd campaign.
apiVersion: v1alpha1
kind: Layer2VIPConfig
name: 10.2.40.60
link: mgmt0
---
# v30iot: link only, no host addressing — see k8s-1.yaml.
apiVersion: v1alpha1
kind: VLANConfig
name: ens19
vlanID: 30
parent: enp2s0f0np0
up: true
---
# Dedicated Ceph cluster network — see k8s-1.yaml.
apiVersion: v1alpha1
kind: LinkConfig
name: enp2s0f1np1
up: true
mtu: 9000
addresses:
- address: 10.99.0.3/29