The exporter deployed cleanly, ran 3/3 with no restarts, answered its liveness
probe, and produced no drive metrics at all. Only smartctl_devices and
smartctl_exporter_build_info reached Prometheus — a green DaemonSet measuring
nothing, which is the failure mode the dashboard's own caveats panel warns
about.

The logs said why: it found all three drives per node and could open none of
them, with 'Smartctl open device: /dev/nvme0 failed: Operation not permitted'.

EPERM rather than EACCES is the tell — it is the default seccomp action for a
syscall a profile does not list. Rather than guess between that and the
capabilities, I read /proc/1/status in the running container: CapEff was
0x220000, so SYS_ADMIN and SYS_RAWIO were both effective, while Seccomp was 2
with one filter loaded. The capabilities were never the problem. The kubelet
runs with seccompDefault: true, so every pod that does not say otherwise gets
RuntimeDefault.

SELinux was ruled out the same way: /sys/fs/selinux/enforce reads 0.

This stays narrower than privileged: true, which would additionally grant every
capability, all host devices and write access to /sys. The tighter option is a
custom seccomp profile allowing exactly the ioctl smartctl issues; that is worth
building if this set of exceptions ever grows, and is not worth it for one pod.

Refs #549
2026-08-27 15:03:34 +02:00
k.renner 04df5da041 Merge pull request 'feat(monitoring): expose NVMe endurance, with the privilege exception it needs' (#669) from smartctl-exporter into master
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#669
2026-08-27 12:56:00 +00:00
claude-botandClaude Opus 5 e8b217e8a1 feat(monitoring): expose NVMe endurance, with the privilege exception it needs
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
Drive wear has been invisible in every signal this cluster has. `ceph -s` reads
active+clean at any wear level, no Ceph health check fires until a device
actually fails, and the block-layer metrics show throughput and latency but
never endurance. That blind spot is how a set of OSD drives reached 81-87%
before anyone looked (#549, #434).

This closes it for every drive, and it costs a deliberate exception to the
no-privileged-containers rule. The owner made that call explicitly after being
shown the alternative.

The alternative was real and is worth recording. Ceph's devicehealth module
already archives complete smartctl output daily — percentage_used,
power_on_hours, media_errors, critical_warning, available_spare — collected
without any elevated privileges, because the OSD pods hold the device access
already. Exporting that needs no exception at all. It also covers OSDs and
nothing else: three of nine drives here, and the six it misses include the ones
retired from Ceph for wear that now carry EPHEMERAL. Monitoring the healthy
drives while leaving the worn ones dark was not worth a new service.

The requirement comes from the kernel, not from the tool. NVMe health is read
through an admin ioctl on the character device, which is gated on CAP_SYS_ADMIN;
sysfs publishes the controller temperature and nothing more. Swapping
smartctl_exporter for another exporter would not change that, so the header says
so — the thing to re-check one day is whether the kernel grew a sysfs interface,
not whether some other tool asks for less.

The exception is kept to the smallest form that works: no `privileged: true`, no
host namespaces, no hostPID. Root plus CAP_SYS_ADMIN and CAP_SYS_RAWIO, all
other capabilities dropped, a read-only root filesystem, and /dev as the only
host mount — required because Kubernetes cannot hand individual character
devices to a pod without a device plugin. The admission policy that forbids
privileged pods is bound to the woodpecker-ci namespace only, so nothing here
circumvents it; monitoring already enforces pod-security `privileged`.

Two details that would otherwise have made the metrics useless:

The ServiceMonitor relabels the pod's node onto every series. Without it each
sample carries only the DaemonSet pod's IP, which says nothing about which
machine the drive is in and changes on every reschedule — an unattributable wear
figure is most of the value gone.

No --smartctl.device list. The exporter scans and rescans on its own, and a
written-down device list would quietly stop covering a drive the next time one
is replaced. Device names are not stable across these machines in the first
place.

The alert rules deliberately separate wear from damage: a wear percentage is a
budget being spent and warns at 80, while spare exhaustion, a critical-warning
flag or new media errors mean the drive is failing now. Media errors alert on
the increase rather than the total, so a drive that recorded errors long ago
does not alert forever while one that starts failing today does.

The completeness check compares the number of reporting drives against
node-exporter's own NVMe inventory rather than a written-down fleet size, so
adding or removing a drive moves both sides together. A rule that alerts on
nothing looks exactly like a healthy cluster, which is the failure mode worth
guarding.

Dashboard panels follow separately, once the metrics are live and the label
names can be read off the real series rather than guessed from a README.

Closes #549

Co-Authored-By: Claude Bot <claude-bot@renner.uno>
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 14:42:18 +02:00
k.renner 8c03a6e310 Merge pull request 'feat(monitoring): put the disk health verdict on the disk health dashboard' (#668) from disk-dashboard-status into master
ci/woodpecker/cron/issue-fix Pipeline was successful
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#668
2026-08-27 12:25:39 +00:00
claude-bot 1213c771ca fix(monitoring): state mechanisms in the panel text, not the current hardware
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
The descriptions I wrote listed the drives fitted today: which model holds which
role, that nvme0 is the system disk on two named nodes and something else on the
third, that a count below three means a drive is gone. All true this afternoon,
none of it true after the next swap — and prose does not get re-read when
hardware changes. That is the same failure this session already found in the
velero schedule comment, in the ci-claude consumer list, and in an instruction
pointing at a deleted file. I built a fresh instance of it while writing about
the others.

The text now describes mechanisms that outlive any particular set of drives, and
points at the inventory table for anything specific. Roles are assigned by serial
in Talos and by by-id path in Rook; a broad `disk.transport == 'nvme'` selector
matches every drive in the box; a drive retired from Ceph is not necessarily out
of service. None of that changes when the hardware does.

The OSD-count panel had the same problem in a worse form, since it was a
threshold rather than a sentence: green at exactly 3. It now reads OSDs down and
out as a difference against ceph_osd_metadata, so growing or shrinking the
cluster does not turn the panel red.

Fixes a claim that was simply false: the inventory description said the OSD
column came from ceph_disk_occupation, and the query never joined it. There was
no such column. It exists now, as a PromQL outer join — the matched half via
group_left, the unmatched half via `unless`, unioned — so drives with no OSD
still appear. Verified against the live TSDB: nine rows, three carrying a
ceph_daemon.

A Grafana `merge` transformation would have been the shorter route and would not
have worked. Merge only combines rows whose shared fields all agree, and the two
queries disagree on `instance` and `job` — node-exporter reports an IP and port
where ceph-mgr reports a node name — so it would have produced twelve rows
instead of nine, silently. Doing the join in PromQL also made it testable before
commit rather than after deploy.

Temperature thresholds are now labelled as generic NVMe limits rather than any
drive's rating, since they are not derived from a datasheet.

Refs #549
2026-08-27 14:23:36 +02:00
claude-botandClaude Opus 5 afbb6c3a95 feat(monitoring): put the disk health verdict on the disk health dashboard
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
The first version graphed throughput, latency and temperature but never answered
"is anything wrong". Establishing that still meant querying Prometheus and Ceph
by hand — which is exactly the work a dashboard exists to remove, and which the
next person would have had to repeat.

A status row now leads: Ceph health, OSDs up and in, Ceph capacity used, and the
fullest EPHEMERAL volume across the three nodes. Each expression was run against
the live TSDB before being written in.

EPHEMERAL fill level gets its own graph too. It was the one number checked by
hand that had no home here, and it is the failure that has no safety net: Ceph
rebalances away from a full OSD, nothing rebalances away from a full /var — the
node simply stops.

The caveats panel gains three things found while answering the question:

Ceph does hold wear for the OSDs, in its devicehealth module and not in
Prometheus. The panel names the command rather than the current value, because a
number written into a dashboard is stale the moment it is written. It also
records that the retired Crucial drives were purged from Ceph's device registry,
so their history is not recoverable either — verified by asking for it and
getting ENOENT.

Talos boots with nvme_core.io_timeout=4294967295, so NVMe commands never time
out. A dying drive stalls instead of returning errors, and the latency panel
goes flat rather than spiking. That inverts what a reader would otherwise
conclude from a quiet graph.

Talos kernel logs do not reach Loki — the only log jobs are Kubernetes pods and
a systemd-journal from elsewhere. I found this by searching Loki for NVMe errors,
getting nothing, and checking whether the collector existed before believing the
zero; it did not. talosctl dmesg is the only source, it is a ring buffer, and
this morning's reboots emptied it.

Refs #549

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 14:18:11 +02:00
k.renner 32dc191b18 Merge pull request 'feat(monitoring): add a disk health dashboard' (#667) from disk-dashboard into master
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#667
2026-08-27 12:06:02 +00:00
claude-botandClaude Opus 5 d04b09310f feat(monitoring): add a disk health dashboard
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
Throughput, IOPS, mean operation latency, utilisation, queue depth and
controller temperature for all nine NVMe drives, plus Ceph's own OSD latency for
comparison against the block layer.

Every panel joins node_disk_* to node_nvme_info and node_uname_info rather than
plotting the device name. That is not decoration: nvme0 is the Kingston system
disk on k8s-1 and k8s-3 and the Crucial on k8s-2, so a legend keyed on the
device compares different hardware across nodes and does so silently. The
inventory table resolves the OSD column through ceph_disk_occupation for the
same reason — it follows Rook instead of restating a device list that goes stale
the next time a drive is swapped.

Every expression was run against Prometheus before being written into the JSON,
which is also how the caveats in the panel descriptions were found. Latency is
accumulated-time over completed-operations, so it is a mean with no tail and it
vanishes while a device is idle: absence of traffic, not absence of a problem.
Utilisation near 100% on NVMe does not mean saturation the way it does on a
spindle, which is why queue depth shares that panel.

Temperature is the only SMART-adjacent value present, because it is the only one
the kernel publishes through sysfs. Wear, written-bytes totals, power-on hours
and media errors need an NVMe admin ioctl and no exporter here produces them
(#549). The dashboard says so in a panel rather than letting a green screen imply
a healthy drive.

That gap is worse than #549 describes, and the note records why. The Crucial P3
drives were retired from Ceph because they were worn, and now carry the
EPHEMERAL volume — so the drives with the least endurance left are the ones
holding container state, and they are the ones nothing watches. The measured
write latency already separates them from the Samsung OSDs by more than an order
of magnitude.

Also fixes the add-a-dashboard instructions above the generator, whose third
step told the reader to tick a row off ../DASHBOARD-MIGRATION.md. That file does
not exist anywhere in the repo, so the step could not be followed.

Refs #549

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 14:02:11 +02:00
k.renner dd050d811d Merge pull request 'chore(ci): bump ci-claude image to 2.1.247' (#666) from ci-image/claude-2.1.247 into master
ci/woodpecker/push/ci-claude-refresh Pipeline was successful
ci/woodpecker/cron/alert-monitor Pipeline was successful
ci/woodpecker/cron/e2e Pipeline was successful
Reviewed-on: k.renner/homelab#666
2026-08-27 11:51:32 +00:00
claude-bot c4bb35173d fix(ci): derive the ci-claude consumer list instead of maintaining it
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
review-bot found that this bump reached five of seven consumers: e2e.yml and
ci-scripts-test.yml stayed on the old version. Verified — both still pinned the
previous tag on the bump branch while the other five moved.

The cause is worth more than the symptom. ci-claude-refresh.yml carried the
consumer list twice, hardcoded, under the instruction "keep this list in sync
with the consumers". It was not in sync, and nothing could ever notice: the two
missing files were invisible to the bump that would have raised them and to the
guard that checks the pins agree. They were not drifting slowly, they were
unreachable — no future run would have touched them either.

So both copies are now derived by grepping .woodpecker for a version-pinned
reference. A list that must be maintained by hand is the defect; deriving it
removes the failure mode rather than correcting one instance of it.

The pattern deliberately matches a digit after the tag, which is what keeps this
file out of its own consumer set — its steps run ci-claude:latest, which never
needs rewriting. That makes the exclusion load-bearing, so it is spelled out in
a comment: a literal version anywhere in this file, prose included, would add it
to the set and let the sed rewrite it. The tag-scheme note at the top now says
<claude-version> for exactly that reason.

An empty result is a hard stop. Without it the following grep would be invoked
with no file arguments, read stdin, and hang rather than fail — a pipeline that
never finishes is worse than one that exits non-zero.

The generated PR body no longer claims a fixed "5 pipelines"; it counts.

Both files are also bumped here rather than left for a follow-up, and the order
matters: adding them to the consumer set without bumping them would make the
next refresh see two disagreeing tags and abort with "refusing to guess". That
guard is well built — it simply never saw these two files.

Refs #666
2026-08-27 13:19:41 +02:00
claude-bot a9df3ea9ce chore(ci): bump ci-claude image to 2.1.247
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
2026-08-27 11:12:42 +00:00
k.renner 2549535961 Merge pull request 'ci(kaniko): move the remaining eight builds to the maintained fork' (#665) from kaniko-fork-rest into master
ci/woodpecker/push/ci-claude-refresh Pipeline was successful
ci/woodpecker/push/build-ci-images Pipeline was successful
ci/woodpecker/cron/issue-fix Pipeline was successful
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#665
2026-08-27 11:11:22 +00:00
claude-botandClaude Opus 5 60f231f839 ci(kaniko): move the remaining eight builds to the maintained fork
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
ci/woodpecker/push/build-ci-images Pipeline was successful
Pipeline 6861 answered the question the staged first step was there to ask.
build-alpine-jq ran on the fork's v1.25.18, unpacked the rootfs, executed the
RUN, and pushed both destinations to the Gitea registry at digest a430c9c6 —
while the seven untouched kaniko steps stayed green in the same run. The
executor behaves the same and the registry auth path is unaffected, so the rest
can follow.

This moves the other seven steps here plus the one in ci-claude-refresh.yml.
Nothing but the image: lines change; no flags, no commands, no credentials.
That leaves zero gcr.io/kaniko-project references in the pipelines.

The per-step note from the first commit is gone. It described a migration state
that no longer exists, and a comment that survives its own situation is how the
velero schedule ended up claiming there was no CNPG cluster in a namespace that
had one. The durable half moved to the file header, where it explains why the
kaniko image is not Google's and why the pin is past the version their repo
ended on.

Also corrects the admission policy's comment, which cited
gcr.io/kaniko-project/executor as the image its exemption was verified against.
Worth being precise about what did not change: the policy matches on the buildx
plugin image only and never on kaniko, so the swap needed no policy edit — which
is exactly why the stale image reference in the prose was easy to miss.

Closes #552

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 13:03:18 +02:00
k.renner b03d0652c2 Merge pull request 'ci(kaniko): move alpine-jq to the maintained fork' (#664) from kaniko-replacement into master
ci/woodpecker/cron/alert-monitor Pipeline was successful
ci/woodpecker/push/build-ci-images Pipeline was successful
Reviewed-on: k.renner/homelab#664
2026-08-27 10:58:49 +00:00
claude-botandClaude Opus 5 4e040c5a2d ci(kaniko): move alpine-jq to the maintained fork
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/push/build-ci-images Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
#552 concluded that kaniko is terminal and that the nine build steps need
migrating to buildah or BuildKit. The premise is wrong. Google archived
GoogleContainerTools/kaniko on 2025-06-03, but the original authors forked it to
chainguard-dev/kaniko and kept shipping: releases run to v1.25.18, well past the
v1.24.0 the Google repo ended on. Upstream moved, it did not die.

So this is an image swap, not a migration. Same /kaniko/executor, same flags,
nothing else in the step changes. The fork publishes no binaries of its own, so
the image comes from gitlab-ci-utils, which builds it from that fork for amd64
and arm64 with versioned tags — the generic :debug tag exists too and is
deliberately not used, since every other image reference here is pinned.

Verified by pulling the image and running it rather than by reading its README:
/kaniko/executor is at the same path and reports v1.25.18, /bin/sh is a symlink
into busybox, and printf, base64, tr, mkdir and date are all present — the
utilities the auth and tag lines depend on. Anonymous pull works, so no registry
credential is needed for it.

Only this one step moves. A change to this file rebuilds every step regardless,
so a single run puts the new executor on alpine-jq beside seven unchanged kaniko
builds and shows both in the same log. alpine-jq is the smallest context here,
one FROM and one RUN, and the remaining seven plus ci-claude-refresh.yml follow
once this is green.

Two counts in #552 are also wrong and worth correcting there: the pin was
v1.23.2-debug everywhere, not v1.24.0-debug — #551 bumped alpine, not kaniko —
and there are eight steps in this file plus one in ci-claude-refresh.yml, so
nine invocations rather than ten.

Refs #552

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 12:54:24 +02:00
k.renner 900bc73635 Merge pull request 'docs: propose separating the four traffic classes onto their own VLANs' (#663) from proposal-traffic-classes into master
ci/woodpecker/cron/issue-fix Pipeline was successful
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#663
2026-08-27 10:26:58 +00:00
k.renner a65109fee0 Merge pull request 'docs(runbook): drop the claim that a cold rebuild needs console access' (#662) from runbook-remote-rebuild-possible into master
Reviewed-on: k.renner/homelab#662
2026-08-27 10:26:30 +00:00
k.renner 477b79cdc6 Merge pull request 'fix: [alert] VeleroBackupFailed (velero) (#657)' (#659) from alert-fix/issue-657 into master
Reviewed-on: k.renner/homelab#659
2026-08-27 10:26:03 +00:00
claude-botandClaude Opus 5 55ea98c035 docs: answer the direct-routing question from source instead of a test
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
The first draft ended on an open question and proposed a two-VM sandbox to
answer it. That was unnecessary: the question is answerable from the Cilium
source and the agent flag reference, and the answer is negative.

installDirectRoute takes its next-hop as a parameter, and nodeUpdate supplies
GetNodeIP(false), which prefers NodeInternalIP. NodeInternalIP comes from the
Kubernetes Node object; --ipv4-node looks like an override but initFromK8s()
runs after initFromConfig() and overwrites it. --direct-routing-device selects
a device, not an address. The same value feeds the VXLAN endpoint in tunnel
mode.

So cluster-internal traffic is welded to the kubelet InternalIP, and the routing
mode does not matter — tunnel sources the VXLAN from it, native uses it as the
next-hop. That deletes the one disruptive, non-rolling step the first draft
contained. Native routing buys nothing for this problem.

Since cluster-internal cannot be moved, the separation has to come from moving
management services off the node IP, and those do not share a mechanism, so each
is checked separately: etcd moves via cluster.etcd.advertisedSubnets, the
apiserver endpoint is already a VIP whose Layer2VIPConfig carries a link field,
the Talos API turned out to answer on every node address, and kubelet cannot
move because it is the node IP.

The result is four VLANs, but the boundary does not fall where the class names
suggest — kubelet stays with cluster-internal. Stated plainly rather than filed
under management and hoped over.

Recommends leaving the node IP where it is and relabelling VLAN 40 as the
cluster VLAN, rather than moving every node's identity to a new VLAN. Same end
state, and the address the cluster is administered through never changes.

Also records that the Ceph pattern is the only mechanism that fully detaches a
workload from the node IP, and that it is too expensive to generalise to
east-west traffic.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 11:49:19 +02:00
claude-botandClaude Opus 5 6a50ab1daa docs: propose separating the four traffic classes onto their own VLANs
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
Issue #576 framed this as "give node management its own NIC, and Ceph public
its own VLAN". That is two of four classes, and one of them turned out to be
solved already — Ceph client I/O riding the pod network is correct, since that
traffic is cluster-internal.

The classes are Ceph replication (done, VLAN 49), cluster-internal,
cluster-external and management. Three of the four share mgmt0, which was never
a decision: until the bare-metal conversion there was one NIC.

Each class gets a VLAN; which interface a VLAN lands on stays a separate and
changeable decision. That ordering means the separation survives recabling and
does not need one port per class.

Three of the four are controllable with documented levers. Management is the
InternalIP and does not move — everything else moves away from it, which is
also the direction that never changes the address the cluster is administered
through. Ingress is CiliumBGPNodeConfigOverride's per-peer localAddress, on a
BGP session that has been running for months. Egress follows the output device
under eBPF masquerading.

Cluster-internal is the one that does not resolve. In tunnel mode VXLAN sources
from the node IP with no documented alternative. Native routing is the way out
and its prerequisite is already met — BGP has been advertising the pod CIDRs to
the UDM all along — but whether nodePort.directRoutingDevice moves the next-hop
address or only the interface is undocumented across the three Cilium pages
checked.

So the proposal ends on a question rather than a plan, and the next step is a
two-interface Talos sandbox, not a cable. If the answer is unfavourable the
design changes, not the wiring.

Records what was measured rather than assumed: the BGP session state, that
Cilium's direct-routing device follows the InternalIP (adding a second address
elsewhere left it on mgmt0), that the override CRD exposes localAddress, and
where Ceph's two address families actually sit.

Also states what the split does not buy. Management shares a 10 Gb link and is
not contended; nothing observed is slow because of this.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 11:34:41 +02:00
claude-botandClaude Opus 5 f51eb8bf35 docs(runbook): drop the claim that a cold rebuild needs console access
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
The rewrite earlier today stated, at the top and again in known gaps, that the
rebuild cannot be driven remotely: management is a tagged VLAN, a maintenance
mode node cannot configure VLANs, so it comes up unreachable and every machine
needs a keyboard.

That is wrong. A maintenance-mode node DHCPs untagged and is reachable at that
address — it is not on management, but it answers, and that is precisely the
address `apply-config --insecure` targets in Step 2. All three bare-metal
conversions were driven that way.

The claim came from #576 and was carried into this document without being
checked against what had actually happened days earlier in this repo. It is the
worst place to put an unverified constraint: a disaster-recovery runbook is read
when there is no capacity to discover that a stated prerequisite is fiction, and
"you need physical access to three machines" is exactly the kind of statement
that changes whether someone attempts a recovery at all.

What survives is narrower and true: MS-01 has no IPMI and nothing here does
PXE, so booting from USB is physical. Everything after the boot is remote.

Also removes the follow-on error from the first correction, which claimed the
switch port change on 2026-08-27 had fixed a reachability problem. There was no
reachability problem to fix. That change is real and useful — a maintenance mode
node now lands in management rather than the fallback network — but it did not
turn an impossible rebuild into a possible one.

#576 still carries the original claim and is flagged in known gaps as wrong.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 11:25:50 +02:00
k.renner d1e072146f Merge pull request 'docs(runbook): rewrite the cold rebuild for bare metal' (#661) from runbook-cold-rebuild-baremetal into master
ci/woodpecker/cron/issue-fix Pipeline was successful
ci/woodpecker/cron/alert-monitor Pipeline was successful
Reviewed-on: k.renner/homelab#661
2026-08-27 08:11:24 +00:00
claude-botandClaude Opus 5 4678f73e9f docs(runbook): rewrite the cold rebuild for bare metal
ci/woodpecker/pr/ci-manifests-test Pipeline was successful
ci/woodpecker/pr/ci-scripts-test Pipeline was successful
ci/woodpecker/pr/pr-review Pipeline was successful
Step 1 was "tofu: provision the VMs" and there are no VMs. The OpenTofu stack
has no node definitions left — only the uninstantiated proxmox_vm module beside
DNS, object storage and UniFi — so `tofu apply` provisions nothing and Step 2
then has no cluster to form. The document was half-updated: it knew k8s-1 was
bare metal but still treated k8s-2 and k8s-3 as Proxmox VMs, which stopped
being true at the neptune conversion.

That matters more than an ordinary stale doc, because it is the document
someone reaches for when everything is gone — exactly when there is no capacity
to discover that step one is fiction.

Step 1 splits into two unrelated halves: a tofu apply for platform resources
that do still exist, and physically booting three machines from install media.

Step 2 stops calling `bootstrap.sh talos`, which cannot generate a config
(#581), and carries the procedure that actually works — the one
RUNBOOK-baremetal-conversion.md uses. Both traps it hides are now stated: the
whole cilium-cni.yaml cannot be passed as a patch, and the generated
HostnameConfig collides with the per-node hostname. So is the two-stage apply:
a config referencing an interface that does not exist yet hangs the install at
STAGE: Installing with nothing timing out.

Scoped that claim rather than repeating "bootstrap.sh is dead" wholesale — the
flux and wait-apps phases are still used in Steps 3, 5 and 6 and work. Only
config generation is broken, and saying otherwise would have left the runbook
contradicting itself three sections later.

Adds the constraint that decides whether this is even attemptable remotely, at
the top and again in known gaps: management is a tagged VLAN, a maintenance
mode node cannot configure VLANs, and MS-01 has no IPMI. Every node needs a
keyboard and a monitor until #576 puts VLAN 40 native on the I226-V port. That
was true before today and undocumented.

Also records what changed under the runbook recently: the schematic now carries
i915, Ceph's cluster network is a Multus attachment rather than host
networking, and OpenBao runs three replicas that each need unsealing
individually — a sealed server is neither a voter nor a standby, so doing one
leaves the cluster short of quorum.

Disk verification before install is now explicit. Talos enumerates NVMe in an
order that is not stable across boots, the per-node configs select by serial for
that reason, and the failure mode is the installer taking the Ceph OSD drive.

Closes #660.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-27 10:09:50 +02:00
19 changed files with 1086 additions and 71 deletions
+1 -1
View File
@@ -101,7 +101,7 @@ steps:
bash scripts/ci/make-diag-kubeconfig.sh
- name: alert-triage-agent
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
environment:
CLAUDE_CODE_OAUTH_TOKEN:
from_secret: claude_code_oauth_token
+19 -8
View File
@@ -1,6 +1,17 @@
# Builds the CI tooling images (and the secret-rotator runtime image) with
# kaniko and pushes them to the Gitea container registry.
#
# The kaniko image is NOT Google's. Google archived
# GoogleContainerTools/kaniko on 2025-06-03, but the original authors forked
# it to chainguard-dev/kaniko and kept releasing — the pin here is well past
# the v1.24.0 the Google repo ended on. The fork ships no binaries or images
# of its own, so these come from gitlab-ci-utils, which builds that fork for
# amd64 and arm64 under versioned tags. A generic `:debug` tag exists there
# and is deliberately unused; everything else in this repo is pinned too.
#
# The executor path, flags and busybox layout are unchanged from Google's
# image, which is why the swap touched nothing but the `image:` lines (#552).
#
# Credential: ci_images_token — a PAT scoped to `package: read+write` and
# NOTHING else (verified: 403 on /user/repos, /admin/users and the issues
# API; 200 on the /v2/ registry endpoints kaniko uses). It replaces the
@@ -25,7 +36,7 @@ when:
steps:
- name: build-ansible
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/ansible
depends_on: []
# Only rebuild when THIS image's source (or the pipeline file) changed, or
@@ -53,7 +64,7 @@ steps:
--destination gitea.renner.uno/gitea_admin/ci-ansible:latest
- name: build-k8s
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/k8s
depends_on: []
when:
@@ -77,7 +88,7 @@ steps:
--destination gitea.renner.uno/gitea_admin/ci-k8s:latest
- name: build-tofu
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/tofu
depends_on: []
when:
@@ -108,7 +119,7 @@ steps:
# Runtime image, not CI tooling: a static musl binary in a FROM-scratch image,
# used as the base for secret-rotation CronJobs. Replaces per-job inline Python.
- name: build-secret-rotator
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: secret-rotator
depends_on: []
when:
@@ -137,7 +148,7 @@ steps:
# container, but nothing about it is zigbee-specific. Exists so tools come from
# the image rather than an `apk add` on every container start.
- name: build-alpine-jq
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/alpine-jq
depends_on: []
when:
@@ -166,7 +177,7 @@ steps:
# critical path of every node rebuild. The download now happens here, once,
# where the sha256 is checked — see the Containerfile for the full rationale.
- name: build-cni-plugins
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/cni-plugins
depends_on: []
when:
@@ -195,7 +206,7 @@ steps:
# every paperless pod start. The openssl CLI is genuinely absent from the alpine
# base, so this one needs an image rather than a busybox substitute.
- name: build-alpine-openssl
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/alpine-openssl
depends_on: []
when:
@@ -224,7 +235,7 @@ steps:
# Ansible converge. Not a ci-* image -- it is a runtime artifact -- but it
# builds the same way and lands in the same registry so the audit sees it.
- name: build-heating-can
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/heating-can
depends_on: []
when:
+25 -18
View File
@@ -18,7 +18,7 @@
# consumer pins to ci-claude:<version> and open a PR. A human
# reviews and merges it; nothing auto-merges.
#
# TAG SCHEME — deliberately version tags (ci-claude:2.1.218), NOT the dated
# TAG SCHEME — deliberately version tags (ci-claude:<claude-version>), NOT the dated
# tags the other ci-* images use. The tag encodes the thing that changes here
# (the Claude version), which makes "did it change?" a trivial, race-free
# string compare and keeps the weekly cron from opening no-op PRs. The other
@@ -84,14 +84,24 @@ steps:
- |
set -eu
mkdir -p "$$CI_WORKSPACE/.ci-refresh"
# Files that pin the image. Keep this list in sync with the consumers.
CONSUMERS="
.woodpecker/security-scan.yml
.woodpecker/alert-monitor.yml
.woodpecker/update-audit.yml
.woodpecker/pr-review.yml
.woodpecker/issue-fix.yml
"
# Files that pin the image, DISCOVERED rather than listed. This used to
# be a hardcoded list carrying the instruction "keep this in sync with
# the consumers" — and it was not: e2e.yml and ci-scripts-test.yml were
# missing, so they sat on a version no bump could ever reach. A list
# that must be maintained by hand is the bug; deriving it removes the
# failure mode instead of correcting one instance of it.
#
# Matches a version-pinned reference only, which is what excludes this
# file: its own steps run ci-claude:latest, and :latest never needs
# rewriting. That exclusion is load-bearing — do not write a literal
# ci-claude version anywhere in THIS file, not even in prose, or it
# adds itself to the consumer set and the sed below rewrites it. The
# tag-scheme note at the top says <claude-version> for that reason.
CONSUMERS=$$(grep -rlE 'ci-claude:[0-9]' .woodpecker)
# An empty list would make the grep below read stdin and hang forever
# rather than fail, so it is a hard stop.
[ -n "$$CONSUMERS" ] || { echo "No ci-claude consumers found — refusing to continue."; exit 1; }
echo "consumers: $$CONSUMERS"
NEW=$$(npm view @anthropic-ai/claude-code version)
case "$$NEW" in
[0-9]*.[0-9]*.[0-9]*) : ;;
@@ -130,7 +140,7 @@ steps:
# --build-arg to the resolved version (not "latest") guarantees the tag and
# the image content agree even if a new release lands mid-run.
- name: build
image: gcr.io/kaniko-project/executor:v1.23.2-debug
image: registry.gitlab.com/gitlab-ci-utils/container-images/kaniko:v1.25.18-debug
directory: ci/images/claude
depends_on: [decide]
environment:
@@ -176,13 +186,10 @@ steps:
echo "Branch $$BRANCH already exists — a PR for $$NEW is already open. Nothing to do."
exit 0
fi
CONSUMERS="
.woodpecker/security-scan.yml
.woodpecker/alert-monitor.yml
.woodpecker/update-audit.yml
.woodpecker/pr-review.yml
.woodpecker/issue-fix.yml
"
# Same discovery as the decide step — see the comment there for why this
# is not a maintained list.
CONSUMERS=$$(grep -rlE 'ci-claude:[0-9]' .woodpecker)
[ -n "$$CONSUMERS" ] || { echo "No ci-claude consumers found — refusing to continue."; exit 1; }
# Exact-string swap of the current tag for the new one, consumers only.
for f in $$CONSUMERS; do
sed -i "s#ci-claude:$$CUR#ci-claude:$$NEW#g" "$$f"
@@ -198,7 +205,7 @@ steps:
{
printf 'Automated bump of the ci-claude agent image from `%s` to `%s`.\n\n' "$$CUR" "$$NEW"
printf 'The refresh pipeline built and pushed `ci-claude:%s` (and `:latest`) from the\n' "$$NEW"
printf 'latest published `@anthropic-ai/claude-code`. This rewires the 5 pipelines that\n'
printf 'latest published `@anthropic-ai/claude-code`. This rewires the %s pipelines that\n' "$$(printf '%s\n' $$CONSUMERS | grep -c .)"
printf 'run the image so CI stops running a stale Claude Code.\n\n'
printf 'Merging is a human decision — review, then merge to roll it out.\n'
} > /tmp/pr-body.md
+1 -1
View File
@@ -17,6 +17,6 @@ when:
steps:
- name: model-selection-tests
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
commands:
- sh scripts/ci/test-model-selection.sh
+1 -1
View File
@@ -25,7 +25,7 @@ steps:
# fetch-models.sh response mapping. No cluster, no secrets, no network — the
# ci-claude image just provides sh + jq. Keeps the flag-injection regression
# test from rotting (it exercises the exact injection shapes).
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
commands:
- sh scripts/ci/test-model-selection.sh
+1 -1
View File
@@ -62,7 +62,7 @@ steps:
- bash scripts/ci/make-diag-kubeconfig.sh
- name: issue-fix-agent
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
environment:
CLAUDE_CODE_OAUTH_TOKEN:
from_secret: claude_code_oauth_token
+1 -1
View File
@@ -65,7 +65,7 @@ when:
steps:
- name: pr-review-agent
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
environment:
CLAUDE_CODE_OAUTH_TOKEN:
from_secret: claude_code_oauth_token
+1 -1
View File
@@ -42,7 +42,7 @@ steps:
# this step is skipped — otherwise we'd fork-bomb PRs.
when:
- branch: master
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
environment:
CLAUDE_CODE_OAUTH_TOKEN:
from_secret: claude_code_oauth_token
+1 -1
View File
@@ -30,7 +30,7 @@ when:
steps:
- name: update-audit-agent
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.218
image: gitea.renner.uno/gitea_admin/ci-claude:2.1.247
environment:
CLAUDE_CODE_OAUTH_TOKEN:
from_secret: claude_code_oauth_token
@@ -0,0 +1,194 @@
# Proposal — separate the four traffic classes onto their own VLANs
Status: draft. The question this started with is **answered** — from the Cilium
source and flag reference, not from a test — and the answer changes the shape
of the proposal rather than confirming it.
Supersedes the framing in issue #576, which described this as "give node
management its own NIC, and Ceph public its own VLAN". That was two of four
classes and one of them turned out already solved.
## The four classes
| class | what it is | where it goes today |
|---|---|---|
| **Ceph replication** | OSD-to-OSD heartbeat, replication, recovery | VLAN 49, its own X710 port — **separated** |
| **cluster-internal** | pod-to-pod east-west, including Ceph client I/O | pod network, VXLAN over `mgmt0` |
| **cluster-external** | ingress to LoadBalancer VIPs, egress to LAN and internet | `mgmt0` |
| **management** | Talos API, etcd, kube-apiserver, kubelet | `mgmt0` |
Three of four share one interface. That is not a design decision — until the
bare-metal conversion there was one NIC to work with.
Ceph client I/O living on the pod network is correct rather than a leftover:
that traffic *is* cluster-internal. Ceph is done.
## Principle
**Each class gets its own VLAN. Which physical interface a VLAN lands on is a
separate, changeable decision.**
Defining classes by VLAN means the separation survives recabling, port failures
and capacity changes, and it does not require one port per class. Defining them
by interface would freeze a capacity decision into the architecture.
## The finding that shapes everything else
The original open question was whether `nodePort.directRoutingDevice` moves the
next-hop of Cilium's direct routes, or only selects an interface. It is
answerable from the source, and the answer is: **only the interface.**
`installDirectRoute` takes the next-hop as a parameter:
```go
func installDirectRoute(log *slog.Logger, prefix netip.Prefix, nodeIP net.IP,
skipUnreachable bool) (routeSpec *netlink.Route, err error)
```
and `nodeUpdate` supplies it as `newNode.GetNodeIP(false)`. `GetNodeIP` returns,
in priority order, `NodeInternalIP` → `NodeExternalIP` → anything else. The
same `newIP4` is what tunnel mode uses as the VXLAN endpoint.
`NodeInternalIP` comes from the Kubernetes Node object. `--ipv4-node` looks like
an override but is not one: `initFromConfig()` calls `SetNodeInternalIP` and
`initFromK8s()` runs **after** it and overwrites the value. In a Kubernetes
cluster there is no path by which Cilium's node IP differs from the kubelet's
`InternalIP`.
`--direct-routing-device` is documented as "Device name used to connect nodes in
direct routing mode" — a device, not an address.
**So cluster-internal traffic is welded to the node IP, and the node IP is the
kubelet InternalIP.** Two consequences:
- The class cannot be moved off whatever VLAN the node IP lives on.
- **Routing mode is irrelevant to this problem.** Tunnel mode sources the VXLAN
from the node IP; native mode uses it as the direct-route next-hop. Native
routing buys nothing here, so the disruptive, non-rolling step this proposal
previously contained is simply gone.
## Consequence: draw the line the other way
If cluster-internal cannot leave the node IP, then separation has to come from
moving *management services* off it — and each one has to be checked
individually, because they do not share a mechanism.
| management service | can it leave the node IP? | lever |
|---|---|---|
| etcd | **yes** | `cluster.etcd.advertisedSubnets` (+ `listenSubnets`, which defaults to it) |
| kube-apiserver endpoint | **yes** | already a VIP — `Layer2VIPConfig` with a `link:` field |
| Talos API | **n/a** | `apid` answers on every node address (measured); a client and firewall choice, not a bind setting |
| kubelet | **no** | it *is* the node IP, by definition |
So four VLANs are reachable, but the boundary does not fall where the class
names suggest: **kubelet stays with cluster-internal.** That is the honest
result, and it is worth stating plainly rather than filing kubelet under
management and hoping.
The remaining classes keep the levers established earlier:
- **cluster-external ingress** — `CiliumBGPNodeConfigOverride.spec.bgpInstances[].peers[].localAddress`.
For eBGP the session source is the next-hop, so pinning the session pins
where return traffic arrives. The session to the UDM has been running for
months.
- **cluster-external egress** — eBPF masquerading follows the output device, so
this is a default-route decision plus `enable-masquerade-to-route-source`
(today `false`).
- **Ceph replication** — Multus macvlan on VLAN 49, done.
## The general escape hatch
Ceph is separated because its OSDs got a second interface and stopped using the
pod network for replication. That is the *only* mechanism that fully detaches a
workload from the node IP, and it generalises: anything that must not ride the
node IP gets its own `NetworkAttachmentDefinition`.
It is also expensive per workload — an attachment, an IPAM pool, a pod spec
change. Worth it for Ceph replication. Not worth it for east-west traffic in
general.
## Recommended mapping
Two ways to arrange this, and they differ only in which VLAN gets relabelled:
**A — move the node IP to a new cluster VLAN.** VLAN 40 keeps etcd, the API VIP
and Talos API. Cleanest match to the class names, but it changes every node's
identity, which is the one address the whole cluster is administered through.
**B (recommended) — leave the node IP on VLAN 40 and move management off it.**
VLAN 40 becomes the cluster VLAN; a new VLAN carries etcd and the API VIP.
Identical end state, and no node ever changes its InternalIP.
Under B:
| VLAN | carries |
|---|---|
| 49 | Ceph replication |
| 40 (relabelled *cluster*) | pod east-west, kubelet |
| new *management* | etcd, kube-apiserver VIP, Talos API by convention |
| new *external* | LoadBalancer ingress, egress default route |
The property the user asked for — management carries only management traffic —
holds under B. The label moves; the property is what matters.
## Migration shape
Every step is rolling and reversible. The routing-mode change is gone.
1. **New VLANs** on the switch, trunked to the X710. Nothing uses them.
2. **Addresses** on the new VLANs via Talos, one node at a time, `--mode=try`.
Still unused; this only proves the L2 works.
3. **etcd** to the management VLAN via `advertisedSubnets`. One node at a time,
waiting for a healthy quorum between each.
4. **API VIP** to the management VLAN via `Layer2VIPConfig.link`. DNS for
`k8s.renner.uno` follows.
5. **cluster-external**: BGP `localAddress`, default route, masquerade flag.
Reversible by reverting the override; failure is visible immediately in
`cilium-dbg shell -- bgp/peers`.
6. Verify VLAN 40 by what is *absent* from it, not by what still works.
Step 3 is the one that deserves care — etcd is the only step where a mistake
costs quorum rather than connectivity.
## What this does not buy
Management currently shares a 10 Gb link and is not contended. Nothing observed
today is slow because of this. The case for the split is that traffic classes
with different failure modes and security postures should not be
indistinguishable — not that something is broken.
## Sources and measurements
Source, Cilium v1.20.1 (the running version):
- `pkg/datapath/linux/node.go` — `installDirectRoute(…, nodeIP net.IP, …)`,
fed from `newIP4 = newNode.GetNodeIP(false)`; `createDirectRouteSpec` rejects
a next-hop that is not directly reachable.
- `pkg/node/types/node.go` — `GetNodeIP` prefers `NodeInternalIP`.
- `pkg/node/sync/local_node_sync.go` — `initFromConfig()` applies
`--ipv4-node`, `initFromK8s()` runs afterwards and overwrites it from the
Kubernetes Node.
- `cilium-agent` flag reference — `--direct-routing-device`: "Device name used
to connect nodes in direct routing mode".
Talos:
- Multihoming guide — `cluster.etcd.advertisedSubnets`; `listenSubnets`
defaults to it. kube-apiserver and Talos API listen addresses are not
covered there.
- `kubernetes/talos/patches/k8s-{1,2,3}.yaml` — `Layer2VIPConfig` for
`10.2.40.60` with `link: mgmt0`.
Measured on the cluster:
- `apid` answered on a node address that is not the InternalIP, so the Talos
API is not bound to one address.
- k8s-1 currently holds one routable v4 address plus the VIP on `mgmt0`; its
InternalIP had changed since the last session, which is why nothing here
names an address as fixed.
- Cilium runs `routing-mode: tunnel` with `enable-masquerade-to-route-source`
unset and no direct-routing device configured.
Not verified: whether the kube-apiserver's `--advertise-address` follows the
node IP independently of the VIP. It does not affect the recommendation, since
clients reach the API through the VIP either way.
+151 -33
View File
@@ -1,10 +1,25 @@
# Cold-rebuild runbook — homelab cluster from scratch
Rebuild the entire cluster from **this repo + backups only**, assuming nothing
in the cluster survives (all VMs gone, Ceph gone, in-cluster Gitea gone).
in the cluster survives (all three nodes wiped, Ceph gone, in-cluster Gitea
gone).
Order: **tofu → talos → flux → openbao → apps.**
All three nodes are bare-metal MS-01 machines. Nothing provisions them: there
are no VMs to recreate, and OpenTofu owns only DNS, object storage and UniFi.
Step 1 is therefore two unrelated halves — a `tofu apply` for the platform
resources, and physically booting three machines from install media.
**Someone has to be at the machines to boot them from USB** — MS-01 has no IPMI
and nothing here does PXE. Everything after that is remote.
A node in maintenance mode configures no VLANs and DHCPs untagged, so it comes
up on whatever untagged network its ports carry — not on management, which is
a tagged VLAN on the X710 trunk. It is reachable there: that is the address
`apply-config --insecure` talks to in Step 2, and it is how all three
bare-metal conversions were driven. Find the leases on the UDM.
## The circular-bootstrap problem this runbook exists to break
In steady state Flux's `GitRepository flux-system` pulls manifests from the
@@ -61,12 +76,21 @@ These must exist outside the cluster or the rebuild cannot complete:
`openbao-daily` offsite copy. In a total-loss rebuild the offsite Velero
copy is the one that survives.
- [ ] **Tooling:** `talosctl`, `kubectl`, `flux`, `tofu`, `bao`, plus the
OpenTofu backend + Proxmox/UniFi credentials the `opentofu/` stack needs.
OpenTofu backend + UniFi credentials the `opentofu/` stack needs. No
Proxmox credentials — there is no Proxmox any more.
- [ ] **Install media** written and to hand: the Image Factory ISO named in
Step 1, on a USB stick, for all three machines.
- [ ] **Someone at the machines to boot them from USB.** No IPMI, no PXE. A
monitor is useful for reading boot errors but is not required to find the
node afterwards — it DHCPs into management on its own (see the note at
the top). Everything past the boot is remote.
## Step 1 — tofu: provision the VMs + supporting infra
## Step 1a — tofu: DNS, object storage, UniFi
Recreate the Talos VMs and the platform resources OpenTofu owns (Proxmox VMs,
UniFi DNS records incl. `k8s.renner.uno` / node A records, etc.).
OpenTofu no longer provisions any node. The `proxmox_vm` module still exists in
the tree but nothing instantiates it, so `tofu apply` here creates only the
platform resources: UniFi DNS records including `k8s.renner.uno` and the node A
records, the Hetzner object storage, and the NAT hairpin rules.
```sh
cd opentofu
@@ -74,44 +98,119 @@ tofu init -upgrade -backend-config="access_key=..." -backend-config="secret_key=
tofu apply
```
In CI this is `.woodpecker/deploy-infrastructure.yml` (manual, `TOFU_APPLY=true`),
which also pre-seeds the Talos image onto every Proxmox node. Wait until the
node FQDNs (`k8s-{1,2,3}.srv.renner.uno`) resolve and the VMs are up before
Step 2 — `bootstrap.sh` polls DNS but will not create the records.
Run this first regardless, because Step 2 needs `k8s.renner.uno` and the node
FQDNs to resolve — the control-plane endpoint is baked into every generated
config, and the nodes are addressed by name.
**k8s-1 is not a VM and OpenTofu does not create it.** jupiter runs Talos on
bare metal, so this step only provisions k8s-2 (saturn) and k8s-3 (neptune).
Before Step 2, boot jupiter from the bare-metal image below so it comes up in
maintenance mode and answers on `k8s-1.srv.renner.uno` — `bootstrap.sh` treats
all three nodes identically from there, since `apply-config --insecure` does
not care whether the target is a VM or bare metal.
## Step 1b — boot all three machines from install media
```
https://factory.talos.dev/image/0f6fb8bd8bb53013e9743b7c7b099d96fb9c32fd2464ced32693c2dc0ea5feb9/v1.13.9/metal-amd64.iso
```
That schematic is deliberately not the one `.woodpecker/deploy-infrastructure.yml`
seeds onto the Proxmox nodes. It keeps the same `net.ifnames=1` kernel argument
— without it the predictable interface names that `talos/patches/k8s-1.yaml`
matches its VLAN parents against do not exist — and differs in three ways:
Write it to a USB stick and boot each MS-01 from it. Each comes up in
maintenance mode with a DHCP address on an untagged network — not on
management, which is tagged. Read the leases off the UDM; those addresses are
what Step 2 applies the first config to.
- drops `siderolabs/qemu-guest-agent`, which has nothing to talk to on bare metal
- adds `siderolabs/intel-ucode`, since no hypervisor is supplying microcode now
- adds `siderolabs/thunderbolt`, unused so far and inert until
`machine.kernel.modules` requests `thunderbolt`/`thunderbolt_net`. It is
present only so enabling the MS-01 Thunderbolt mesh later does not require a
new image and a reinstall. Note its udev rule auto-authorises any Thunderbolt
device attached to the machine once those modules are loaded.
The schematic `0f6fb8bd…` carries `net.ifnames=1` — without it the predictable
interface names that `talos/patches/k8s-{1,2,3}.yaml` match their VLAN parents
against do not exist, and the node ends up with no address on any interface.
Beyond that it carries:
- `siderolabs/intel-ucode` — no hypervisor supplies microcode here
- `siderolabs/i915` — the Alder Lake-P Iris Xe. Nothing requests `/dev/dri`
today; present so wanting hardware transcoding later is a config change
rather than another rolling reinstall
- `siderolabs/thunderbolt` — inert until `machine.kernel.modules` requests
`thunderbolt`/`thunderbolt_net`, present for the same reason. Note its udev
rule auto-authorises any Thunderbolt device attached once those modules load
- no `qemu-guest-agent`, which has nothing to talk to on bare metal
Verify the disks before going further. Talos enumerates NVMe in an order that
is not stable across boots, and the per-node configs select by serial for
exactly that reason — the failure mode is the installer taking the Ceph OSD
drive. `talosctl -n <maintenance-ip> --insecure get disks` should show three
NVMe devices whose serials match the `diskSelector` and `VolumeConfig` entries
in `talos/patches/k8s-N.yaml`.
## Step 2 — talos: form the cluster + get kubeconfig
**Do not use `kubernetes/bootstrap.sh talos`.** That phase cannot generate a
config: it passes `talos/patches/cilium-cni.yaml` whole, and that file's
`$patch: delete` document fails against a base with no `inlineManifests`
(#581). Its other phases — `flux`, `wait-apps` — are still used, in Steps 3, 5
and 6; only config generation is broken.
The procedure below is what actually works, and is the same one
`RUNBOOK-baremetal-conversion.md` uses.
### Generate the configs
This is a genuinely new cluster — nothing survives to copy secrets from, so
generate them fresh. (In a *partial* rebuild, where one node still runs, pull
secrets off it instead with `talosctl get mc v1alpha1` + `gen secrets
--from-controlplane-config`, or the new node forms its own cluster rather than
joining.)
```sh
kubernetes/bootstrap.sh talos
talosctl gen secrets -o secrets.yaml
for N in 1 2 3; do
talosctl gen config homelab https://k8s.renner.uno:6443 \
--with-secrets secrets.yaml --output-types controlplane \
--config-patch @talos/patches/cluster.yaml \
--config-patch @<cilium additive half> \
--config-patch @talos/patches/registry-mirror.yaml \
--config-patch @talos/patches/k8s-$N.yaml -o install-k8s-$N.yaml
done
```
Generates + applies Talos configs to `k8s-{1,2,3}`, bootstraps etcd/Kubernetes,
writes `~/.talos/config` + `~/.kube/config`, and stages both into
`kubernetes/access-staging/` for later phases. Ends when all 3 nodes are `Ready`.
Two things the generator gets wrong for this repo, both of which will bite
silently:
- **`cilium-cni.yaml` cannot be passed whole** — extract only its additive
second document. See issue #581.
- **Strip the generated `HostnameConfig`** — it collides with
`machine.network.hostname` from the per-node patch.
Validate each before applying:
```sh
talosctl validate --config install-k8s-$N.yaml --mode metal
```
### Apply in two stages
Do **not** apply the full per-node config in maintenance mode. A document that
references an interface which does not exist yet hangs the install: the node
sits at `STAGE: Installing` indefinitely with `KUBELET n/a` and `APISERVER n/a`,
and nothing times out. Concretely, the `ens19` VLAN document must be removed
from the first-stage config — its parent exists, but the install stalls anyway.
```sh
# Stage 1: minimal config, from the maintenance-mode address off the console
talosctl apply-config --insecure -n <maintenance-ip> --file install-k8s-$N-stage1.yaml
# Stage 2: once the node is up on management, apply the complete config
talosctl -n k8s-$N.srv.renner.uno apply-config --mode=try --timeout=5m --file install-k8s-$N.yaml
```
`--mode=try` rolls back on its own if the node becomes unreachable, which is the
only safety net there is for a network change that can strand a machine with no
IPMI. Use it for every network-affecting apply, then make it permanent once
proven.
### Bootstrap etcd, then collect access
Bootstrap **exactly one** node:
```sh
talosctl -n k8s-1.srv.renner.uno bootstrap
talosctl -n k8s-1.srv.renner.uno kubeconfig .
```
Ends when all three nodes are `Ready`. `scripts/import-cluster-access.sh` is the
supported way to get the kubeconfig into place afterwards.
## Step 3 — flux: bootstrap GitOps **from the GitHub mirror** (break-glass)
@@ -231,9 +330,28 @@ it: repo → **Settings → Repository → Mirror Settings** in Gitea, or
in-cluster commits made **after** Flux/Gitea broke are not on the mirror
(Gitea couldn't push them if Gitea itself was down). This is the intended
recovery point, but be aware of it when reconciling drift.
- `bootstrap.sh` has no `openbao` phase — Step 4 is manual because the unseal
key must not live in CI. See issue #187 for the open question of whether to
wire a semi-automated OpenBao restore.
- **Booting is physical; the rest is not.** MS-01 has no IPMI and nothing here
does PXE, so someone has to put a USB stick in three machines. From there it
is remote — a maintenance-mode node DHCPs untagged and is reachable at that
address, which is how all three bare-metal conversions were driven.
#576 claims a freshly booted node "comes up unreachable and must be installed
from a console". That is not what happens and has never been observed here.
- **`bootstrap.sh talos` is dead** — it cannot generate a config (#581), and
Step 2 no longer uses it. Its `flux` and `wait-apps` phases are still used in
Steps 3, 5 and 6 and work; do not read this as the whole script being gone.
It has also never had an `openbao` phase — Step 4 is manual because the
unseal key must not live in CI; see issue #187 on whether to wire a
semi-automated OpenBao restore.
- **OpenBao seals on every restart and each replica must be unsealed
individually.** Three raft replicas mean the service survives losing one, but
a sealed server is neither a voter nor a standby — unsealing only one leaves
the cluster short of quorum. Step 4 covers this; it is repeated here because
it is the step most likely to be half-done under pressure.
- Ceph's cluster network is a Multus attachment on VLAN 49 with whereabouts
IPAM, not host networking. Nothing in the rebuild needs special handling for
it — the nodes hold no address on that segment — but a rebuilt cluster will
not have the whereabouts allocations from before, which is harmless since
they are assigned fresh.
- warn-and-continue waits in the `flux` phase can mask a genuinely broken
Ceph/infra bring-up; always read the phase output rather than trusting the
exit code.
@@ -6,6 +6,7 @@ kind: Kustomization
resources:
- prometheusrule-ceph.yaml
- prometheusrule-cilium.yaml
- prometheusrule-disk-wear.yaml
- prometheusrule-hetzner-backup.yaml
- prometheusrule-loki.yaml
- prometheusrule-mariadb-backup.yaml
@@ -24,4 +25,5 @@ resources:
- home-assistant-servicemonitor.yaml
- immich-servicemonitor.yaml
- loki-servicemonitor.yaml
- smartctl-exporter-servicemonitor.yaml
- probes-blackbox.yaml
@@ -0,0 +1,121 @@
apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
name: disk-wear
namespace: monitoring
labels:
# kube-prometheus-stack's Prometheus resource selects on this label;
# without it the rule is created but never loaded into Prometheus.
release: kube-prometheus-stack
spec:
groups:
- name: disk-wear.rules
rules:
# THE GAP THESE RULES CLOSE
#
# Drive wear is invisible in every other signal this cluster has.
# `ceph -s` reads active+clean at any wear level, no Ceph health check
# fires until a device actually fails, and the block-layer metrics show
# throughput and latency but never endurance. That blind spot is how a
# set of OSD drives reached 81-87% before anyone looked (#549, #434).
#
# The numbers below are wear percentages reported by the drive itself:
# 100 means the manufacturer's rated endurance is used up. Drives do
# not stop at 100 — they typically keep working and start consuming
# spare blocks — so treat these as planning thresholds, not failure
# predictions.
- alert: NvmeDriveWearHigh
# 80% with months of runway left is the point where ordering a
# replacement is still a calm decision rather than an outage.
# `for` is long because wear is monotonic and slow: it cannot
# flap, and a short window would only make the alert noisier
# after a restart.
expr: smartctl_device_percentage_used >= 80
for: 1h
labels:
severity: warning
annotations:
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} is at {{ $value }}% rated wear"
description: >-
The drive has used {{ $value }}% of its rated write endurance.
Nothing is failing and no data is at risk yet. Check what the
drive is carrying before deciding urgency: an OSD is replaceable
with a rebalance, whereas the EPHEMERAL volume has no such
escape — a node simply stops when it goes. The Disk Health
dashboard resolves which drive holds which role.
- alert: NvmeDriveWearCritical
expr: smartctl_device_percentage_used >= 95
for: 1h
labels:
severity: critical
annotations:
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} is at {{ $value }}% rated wear"
description: >-
The drive is at or past the end of its rated endurance. It will
likely keep working for a while, but it is now operating outside
what the manufacturer stands behind, and replacement should be
scheduled rather than considered.
# A drive that has consumed its spare area is no longer masking media
# defects, which is a materially different state from being worn:
# wear is a budget, spare exhaustion is damage.
- alert: NvmeDriveSpareExhausted
expr: smartctl_device_available_spare <= smartctl_device_available_spare_threshold
for: 15m
labels:
severity: critical
annotations:
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} has exhausted its spare area"
description: >-
Available spare has fallen to the manufacturer's threshold. The
drive has run out of reserve blocks to remap failures into.
Replace it.
- alert: NvmeDriveCriticalWarning
# The NVMe critical warning byte is a bitfield: spare below
# threshold, temperature out of range, degraded reliability,
# read-only mode, volatile-memory backup failed. Any non-zero value
# is the drive itself asking for attention.
expr: smartctl_device_critical_warning > 0
for: 5m
labels:
severity: critical
annotations:
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} reports critical warning {{ $value }}"
description: >-
The drive has raised its own critical warning flag. Read the
detail with `smartctl -a` on the node; the value is a bitfield,
not a count.
- alert: NvmeDriveMediaErrors
# Unlike wear, this counter should never move. Alert on the increase
# rather than the absolute value, so a drive that recorded errors
# long ago does not alert forever while a drive that starts failing
# today does.
expr: increase(smartctl_device_media_errors[6h]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "NVMe {{ $labels.device }} on {{ $labels.instance }} recorded {{ $value }} new media errors"
description: >-
The drive reported unrecoverable data-integrity errors in the
last six hours. A healthy drive never increments this. Check
whether Ceph has logged scrub errors on the same node.
# Without this the whole group is silently useless: no series means no
# alert fires, and a dashboard of empty panels reads much like a
# healthy one. This is the check that the checks are running.
- alert: SmartctlExporterIncomplete
# Compared against node-exporter's own NVMe inventory rather than a
# written-down fleet size. Adding or removing a drive then moves both
# sides together, so this cannot rot into a permanent false alarm the
# way a hardcoded count would.
expr: count(smartctl_device_percentage_used) < count(node_nvme_info) or absent(smartctl_device_percentage_used)
for: 30m
labels:
severity: warning
annotations:
summary: "Fewer NVMe drives report SMART than node-exporter can see"
description: >-
Some drives visible to node-exporter are not reporting SMART, or
none are. Either a DaemonSet pod is down or a drive stopped
answering — both mean the wear alerts above have stopped watching
part of the fleet, which looks identical to everything being
fine.
@@ -0,0 +1,29 @@
apiVersion: monitoring.coreos.com/v1
kind: ServiceMonitor
metadata:
name: smartctl-exporter
namespace: monitoring
labels:
app.kubernetes.io/name: smartctl-exporter
# kube-prometheus-stack's Prometheus resource selects ServiceMonitors
# by this label; without it the resource exists but is never
# discovered.
release: kube-prometheus-stack
spec:
selector:
matchLabels:
app.kubernetes.io/name: smartctl-exporter
endpoints:
# smartctl itself polls the drives every 60s, so scraping faster than that
# returns the same numbers with a new timestamp. Wear moves on a scale of
# weeks; 60s is already far finer than the signal.
- port: http-metrics
path: /metrics
interval: 60s
relabelings:
# Without this every series is labelled with the exporter pod's IP and
# nothing else. A DaemonSet pod's IP says nothing about which machine
# the drive is in, and it changes on every reschedule — so the wear
# figure would be unattributable, which is most of its value gone.
- sourceLabels: [__meta_kubernetes_pod_node_name]
targetLabel: node
@@ -0,0 +1,382 @@
{
"annotations": {"list": []},
"description": "NVMe health and performance per node. The top row answers 'is anything wrong'; the graphs below answer 'why'. Panels resolve each drive through node_nvme_info and node_uname_info rather than plotting the Linux device name, because NVMe enumeration order is not guaranteed to agree across machines — the same name can be a different drive on the next node. Which drive currently holds which role is in the inventory table, deliberately not in this text. Endurance/wear is absent; see the note at the bottom and issue #549.",
"editable": true,
"fiscalYearStartMonth": 0,
"graphTooltip": 1,
"id": null,
"links": [],
"panels": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Ceph's overall verdict. A HEALTH_WARN is frequently raised by something unrelated to the drives, so read the detail before treating it as a storage problem.",
"fieldConfig": {
"defaults": {
"color": {"mode": "thresholds"},
"mappings": [{"options": {"0": {"color": "green", "index": 0, "text": "HEALTH_OK"}, "1": {"color": "orange", "index": 1, "text": "HEALTH_WARN"}, "2": {"color": "red", "index": 2, "text": "HEALTH_ERR"}}, "type": "value"}],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 1}, {"color": "red", "value": 2}]},
"unit": "short"
},
"overrides": []
},
"gridPos": {"h": 4, "w": 6, "x": 0, "y": 0},
"id": 10,
"options": {"colorMode": "background", "graphMode": "none", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "ceph_health_status", "legendFormat": "", "refId": "A"}],
"title": "Ceph health",
"type": "stat"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "OSDs the cluster knows about but which are not up, and not in. Both should read zero. Counted as a difference against ceph_osd_metadata rather than compared to a fixed number, so adding or removing an OSD does not turn this panel into a false alarm.",
"fieldConfig": {
"defaults": {
"color": {"mode": "thresholds"},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "red", "value": 1}]},
"unit": "short"
},
"overrides": []
},
"gridPos": {"h": 4, "w": 6, "x": 6, "y": 0},
"id": 11,
"options": {"colorMode": "background", "graphMode": "none", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
"targets": [
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "sum(ceph_osd_metadata) - sum(ceph_osd_up)", "legendFormat": "down", "refId": "A"},
{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "sum(ceph_osd_metadata) - sum(ceph_osd_in)", "legendFormat": "out", "refId": "B"}
],
"title": "OSDs down / out",
"type": "stat"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Raw Ceph capacity in use. The cluster average is the optimistic number: Ceph stops writing when a single OSD crosses the full ratio, so per-OSD headroom is what actually bites.",
"fieldConfig": {
"defaults": {
"color": {"mode": "thresholds"},
"mappings": [],
"max": 1,
"min": 0,
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.75}, {"color": "red", "value": 0.85}]},
"unit": "percentunit"
},
"overrides": []
},
"gridPos": {"h": 4, "w": 6, "x": 12, "y": 0},
"id": 12,
"options": {"colorMode": "background", "graphMode": "area", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "ceph_cluster_total_used_bytes / ceph_cluster_total_bytes", "legendFormat": "", "refId": "A"}],
"title": "Ceph capacity used",
"type": "stat"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Fullest EPHEMERAL volume across the fleet — Talos's /var, holding container images, pod scratch space and kubelet state. A full /var takes the node down, and unlike Ceph nothing rebalances away from it.",
"fieldConfig": {
"defaults": {
"color": {"mode": "thresholds"},
"mappings": [],
"max": 1,
"min": 0,
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.7}, {"color": "red", "value": 0.85}]},
"unit": "percentunit"
},
"overrides": []
},
"gridPos": {"h": 4, "w": 6, "x": 18, "y": 0},
"id": 13,
"options": {"colorMode": "background", "graphMode": "area", "justifyMode": "auto", "orientation": "auto", "reduceOptions": {"calcs": ["lastNotNull"], "fields": "", "values": false}, "textMode": "auto"},
"targets": [{"datasource": {"type": "prometheus", "uid": "prometheus"}, "expr": "max(1 - node_filesystem_avail_bytes{mountpoint=\"/var\"} / node_filesystem_size_bytes{mountpoint=\"/var\"})", "legendFormat": "", "refId": "A"}],
"title": "EPHEMERAL used (worst node)",
"type": "stat"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Which physical drive is which, resolved live rather than written down — this table is the answer to 'what is in the machines', so that no panel description has to be. The OSD column is joined from ceph_disk_occupation, so it follows Rook; a drive with no OSD is carrying either the system disk or EPHEMERAL.",
"fieldConfig": {
"defaults": {
"color": {"mode": "thresholds"},
"custom": {"align": "auto", "cellOptions": {"type": "auto"}, "inspect": false},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "text", "value": null}]}
},
"overrides": []
},
"gridPos": {"h": 9, "w": 24, "x": 0, "y": 4},
"id": 1,
"options": {"cellHeight": "sm", "footer": {"countRows": false, "fields": "", "reducer": ["sum"], "show": false}, "showHeader": true, "sortBy": [{"desc": false, "displayName": "node"}]},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "(label_replace(node_nvme_info * on (instance) group_left(nodename) node_uname_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (nodename, nvmedev) group_left(ceph_daemon) label_replace(label_replace(ceph_disk_occupation, \"nodename\", \"$1\", \"instance\", \"(.*)\"), \"nvmedev\", \"$1\", \"devices\", \"(nvme[0-9]+)n[0-9]+\")) or (label_replace(node_nvme_info * on (instance) group_left(nodename) node_uname_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") unless on (nodename, nvmedev) label_replace(label_replace(ceph_disk_occupation, \"nodename\", \"$1\", \"instance\", \"(.*)\"), \"nvmedev\", \"$1\", \"devices\", \"(nvme[0-9]+)n[0-9]+\"))",
"format": "table",
"instant": true,
"legendFormat": "",
"refId": "A"
}
],
"title": "Drive inventory",
"transformations": [
{
"id": "organize",
"options": {
"excludeByName": {"Time": true, "Value": true, "__name__": true, "cntlid": true, "container": true, "endpoint": true, "instance": true, "job": true, "namespace": true, "pod": true, "service": true, "domainname": true, "machine": true, "release": true, "sysname": true, "version": true, "state": true, "nvmedev": true},
"indexByName": {},
"renameByName": {"nodename": "node", "device": "device", "model": "model", "serial": "serial", "firmware_revision": "firmware", "ceph_daemon": "ceph OSD"}
}
}
],
"type": "table"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Read and write throughput per drive.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "off"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}]},
"unit": "Bps"
},
"overrides": []
},
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 13},
"id": 2,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_read_bytes_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "read {{nodename}} {{model}}",
"refId": "A"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_written_bytes_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "write {{nodename}} {{model}}",
"refId": "B"
}
],
"title": "Throughput",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Completed operations per second. Read together with throughput this separates many small operations from few large ones.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "off"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}]},
"unit": "iops"
},
"overrides": []
},
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 13},
"id": 3,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_reads_completed_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "read {{nodename}} {{model}}",
"refId": "A"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_writes_completed_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "write {{nodename}} {{model}}",
"refId": "B"
}
],
"title": "IOPS",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Mean service time per operation, derived as accumulated time divided by completed operations. This is an average and will not show a tail — a drive can look healthy here while a small fraction of operations stall. The line disappears while a device is idle, because the denominator is zero; that is absence of traffic, not absence of a problem.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "off"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}]},
"unit": "s"
},
"overrides": []
},
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 22},
"id": 4,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_read_time_seconds_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]) / rate(node_disk_reads_completed_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "read {{nodename}} {{model}}",
"refId": "A"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_write_time_seconds_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]) / rate(node_disk_writes_completed_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "write {{nodename}} {{model}}",
"refId": "B"
}
],
"title": "Mean operation latency",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Fraction of wall-clock time the device had at least one operation in flight, and the number of operations queued. Utilisation near 100% on an NVMe drive does not mean saturation the way it does on a spindle — these devices serve many operations in parallel — so read it alongside the queue depth.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "off"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}]},
"unit": "percentunit"
},
"overrides": [
{
"matcher": {"id": "byRegexp", "options": "queue .*"},
"properties": [{"id": "unit", "value": "short"}, {"id": "custom.axisPlacement", "value": "right"}]
}
]
},
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 22},
"id": 5,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(rate(node_disk_io_time_seconds_total{device=~\"nvme[0-9]+n[0-9]+\"}[$__rate_interval]), \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "busy {{nodename}} {{model}}",
"refId": "A"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(node_disk_io_now{device=~\"nvme[0-9]+n[0-9]+\"}, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)n[0-9]+\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "queue {{nodename}} {{model}}",
"refId": "B"
}
],
"title": "Utilisation and queue depth",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Composite temperature reported by each controller, read from hwmon in sysfs. This is the one health value available without an admin ioctl, which is why it is the only SMART-adjacent series on this dashboard. The thresholds are generic NVMe limits rather than any particular drive's rating — check the datasheet before treating a crossing as urgent.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "dashed"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 70}, {"color": "red", "value": 80}]},
"unit": "celsius"
},
"overrides": []
},
"gridPos": {"h": 9, "w": 12, "x": 0, "y": 31},
"id": 6,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "label_replace(node_hwmon_temp_celsius{chip=~\"nvme_nvme[0-9]+\", sensor=\"temp1\"}, \"nvmedev\", \"$1\", \"chip\", \"nvme_(nvme[0-9]+)\") * on (instance, nvmedev) group_left(model) label_replace(node_nvme_info, \"nvmedev\", \"$1\", \"device\", \"(nvme[0-9]+)\") * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "{{nodename}} {{model}}",
"refId": "A"
}
],
"title": "Controller temperature",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "Ceph's own view of the OSDs, for comparison with the block-layer numbers above. A divergence between these and the device latency is the interesting case: it points at Ceph rather than at the hardware.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "off"}},
"mappings": [],
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}]},
"unit": "ms"
},
"overrides": []
},
"gridPos": {"h": 9, "w": 12, "x": 12, "y": 31},
"id": 7,
"options": {"legend": {"calcs": ["mean", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "ceph_osd_apply_latency_ms",
"legendFormat": "apply {{ceph_daemon}}",
"refId": "A"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "ceph_osd_commit_latency_ms",
"legendFormat": "commit {{ceph_daemon}}",
"refId": "B"
}
],
"title": "Ceph OSD latency",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"description": "EPHEMERAL fill level per node. Growth here is usually container images and pod scratch space rather than anything Ceph does.",
"fieldConfig": {
"defaults": {
"color": {"mode": "palette-classic"},
"custom": {"axisCenteredZero": false, "axisColorMode": "text", "axisPlacement": "auto", "barAlignment": 0, "drawStyle": "line", "fillOpacity": 10, "gradientMode": "none", "hideFrom": {"legend": false, "tooltip": false, "viz": false}, "lineInterpolation": "smooth", "lineWidth": 2, "pointSize": 5, "scaleDistribution": {"type": "linear"}, "showPoints": "never", "spanNulls": false, "stacking": {"group": "A", "mode": "none"}, "thresholdsStyle": {"mode": "dashed"}},
"mappings": [],
"max": 1,
"min": 0,
"thresholds": {"mode": "absolute", "steps": [{"color": "green", "value": null}, {"color": "orange", "value": 0.7}, {"color": "red", "value": 0.85}]},
"unit": "percentunit"
},
"overrides": []
},
"gridPos": {"h": 8, "w": 24, "x": 0, "y": 40},
"id": 9,
"options": {"legend": {"calcs": ["last", "max"], "displayMode": "table", "placement": "bottom", "showLegend": true}, "tooltip": {"mode": "multi", "sort": "desc"}},
"targets": [
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"expr": "(1 - node_filesystem_avail_bytes{mountpoint=\"/var\"} / node_filesystem_size_bytes{mountpoint=\"/var\"}) * on (instance) group_left(nodename) node_uname_info",
"legendFormat": "{{nodename}} /var",
"refId": "A"
}
],
"title": "EPHEMERAL usage",
"type": "timeseries"
},
{
"datasource": {"type": "prometheus", "uid": "prometheus"},
"gridPos": {"h": 11, "w": 24, "x": 0, "y": 48},
"id": 8,
"options": {
"code": {"language": "plaintext", "showLineNumbers": false, "showMiniMap": false},
"content": "### What this dashboard cannot tell you\n\nThese notes are about mechanisms, not about the drives currently fitted. The inventory table above is the live answer to what is in the machines; nothing here restates it, because prose does not get re-read when hardware is swapped.\n\n**Endurance is missing.** No wear, no written-bytes total, no power-on hours, no media-error count — no exporter here produces them. NVMe reports those over an admin ioctl that needs elevated privileges; temperature is the only health value the kernel publishes through sysfs. Tracked as **#549**. Do not read a green top row as a healthy drive.\n\nCeph does record wear, but only inside its own devicehealth module and not in Prometheus: `kubectl -n rook-ceph exec deploy/rook-ceph-tools -- ceph device ls`. It covers OSDs and nothing else, and a drive removed from Ceph is purged from that registry — its history goes with it, so the wear figure of a retired drive is not recoverable after the fact.\n\n**Roles are assigned in configuration, not by device name.** Talos selects the system disk and the EPHEMERAL volume by serial, Rook selects the OSD by `/dev/disk/by-id` path. Two consequences outlive any particular set of drives: a broad selector such as `disk.transport == 'nvme'` matches every drive in the box, with the installer taking the OSD as the failure mode — and a drive retired from Ceph is not necessarily out of service, so the drive with the least endurance left can be the one carrying container state.\n\n**A dying NVMe here hangs rather than errors.** Talos boots with `nvme_core.io_timeout=4294967295`, so NVMe commands never time out. Expect a stall, not an I/O error, and expect the latency panel to go flat rather than spike.\n\n**Kernel messages are not retained.** Talos kernel logs do not reach Loki — the only log jobs are Kubernetes pods and a systemd-journal from elsewhere. `talosctl -n <node> dmesg` is the only source, it is a ring buffer, and a reboot empties it. An NVMe error from before the last reboot left no trace anywhere.",
"mode": "markdown"
},
"title": "Gaps and caveats",
"type": "text"
}
],
"preload": false,
"refresh": "1m",
"schemaVersion": 39,
"tags": ["storage", "nvme", "ceph"],
"templating": {"list": []},
"time": {"from": "now-6h", "to": "now"},
"timepicker": {},
"timezone": "",
"title": "Disk Health",
"uid": "disk-health",
"version": 1,
"weekStart": ""
}
@@ -7,9 +7,12 @@ namespace: monitoring
# the kube-prometheus-stack Grafana sidecar watches for.
#
# To add a dashboard:
# 1. Copy the ported JSON to this directory as <name>.json
# 1. Copy the JSON to this directory as <name>.json
# 2. Add a configMapGenerator entry below referencing the file
# 3. Tick off the row in ../DASHBOARD-MIGRATION.md
#
# There used to be a third step, ticking a row off ../DASHBOARD-MIGRATION.md.
# That file no longer exists anywhere in the repo — the port it tracked is
# finished — so following the instruction was impossible.
#
# Dashboard datasource UIDs must match K8s Grafana datasources:
# - prometheus (kube-prom-stack default, in-cluster)
@@ -35,6 +38,9 @@ configMapGenerator:
- name: dashboard-blackbox-overview
files:
- blackbox-overview.json
- name: dashboard-disk-health
files:
- disk-health.json
- name: dashboard-gitea-overview
files:
- gitea-overview.json
@@ -15,6 +15,7 @@ resources:
- prometheus-gate-service.yaml
- prometheus-gate-ingress.yaml
- ci-diagnostics-rbac.yaml
- smartctl-exporter.yaml
- dashboards/
# prometheusrule-garage.yaml lives in ./monitoring-rules/ and is applied by a
# separate Flux Kustomization that dependsOn `monitoring` — otherwise the
@@ -0,0 +1,142 @@
# SMART/endurance metrics for every NVMe drive in the fleet (#549).
#
# WHY THIS HOLDS ELEVATED CAPABILITIES, and why that is a deliberate exception
# rather than an oversight:
#
# NVMe reports health over an admin ioctl on the character device
# (NVME_IOCTL_ADMIN_CMD), which the kernel gates on CAP_SYS_ADMIN. There is no
# sysfs path for wear, media errors or written-bytes totals — hwmon publishes
# the controller temperature and nothing else. Upstream smartctl_exporter
# documents `privileged: true` and `user: root` for exactly this reason.
#
# The alternative that needs no privileges — reading Ceph's devicehealth
# archive, which does hold full smartctl output — covers OSD drives only. In
# this cluster that is three of nine, and the six it misses include the drives
# that were retired from Ceph for wear and now carry EPHEMERAL. Covering the
# healthy drives and not the worn ones was judged not worth a new service; the
# owner chose fleet-wide coverage with the privilege exception instead.
#
# The exception is kept as small as the kernel allows: no `privileged: true`,
# no host namespaces, no hostPID. Only CAP_SYS_ADMIN and CAP_SYS_RAWIO are
# added, everything else is dropped, and the only host mount is /dev — which
# is required because the exporter must open the NVMe character devices and
# Kubernetes has no way to pass individual character devices to a pod without
# a device plugin.
#
# If this ever needs revisiting: the thing to check is whether the kernel has
# grown a sysfs interface for NVMe health, not whether some other exporter
# needs fewer privileges. The requirement comes from the ioctl gate, not from
# the tool.
#
# Upstream had no release between 2025-04-22 (v0.14.0) and this deployment.
# The repository is not archived; the pin is simply its newest tag.
apiVersion: apps/v1
kind: DaemonSet
metadata:
name: smartctl-exporter
namespace: monitoring
labels:
app.kubernetes.io/name: smartctl-exporter
spec:
selector:
matchLabels:
app.kubernetes.io/name: smartctl-exporter
template:
metadata:
labels:
app.kubernetes.io/name: smartctl-exporter
spec:
# Control planes are also the storage nodes here, so the exporter has to
# tolerate the control-plane taint or it would cover nothing at all.
tolerations:
- key: node-role.kubernetes.io/control-plane
operator: Exists
effect: NoSchedule
containers:
- name: smartctl-exporter
image: quay.io/prometheuscommunity/smartctl-exporter:v0.14.0
# No --smartctl.device on purpose: the exporter scans for devices
# itself and rescans every 10m by default. Device names are not
# stable across these machines, so a hardcoded list would quietly
# stop covering a drive the next time one is replaced.
args:
- --web.listen-address=:9633
ports:
- name: http-metrics
containerPort: 9633
protocol: TCP
securityContext:
# Root plus two capabilities, NOT privileged. See the header.
runAsUser: 0
runAsNonRoot: false
privileged: false
allowPrivilegeEscalation: false
readOnlyRootFilesystem: true
capabilities:
drop: ["ALL"]
add: ["SYS_ADMIN", "SYS_RAWIO"]
# The capabilities alone are not enough, and this was measured
# rather than assumed. With the default profile the exporter found
# all three drives and could open none of them:
# "Smartctl open device: /dev/nvme0 failed: Operation not
# permitted"
# EPERM is the default seccomp action for a syscall the profile
# does not list. Reading /proc/1/status in the running container
# separated the two candidates: CapEff was 0x220000, so SYS_ADMIN
# and SYS_RAWIO were both effective — while Seccomp was 2 with one
# filter loaded. The kubelet sets seccompDefault: true, so every
# pod that does not say otherwise gets RuntimeDefault.
#
# This is still narrower than `privileged: true`, which would also
# grant every capability, all devices and write access to /sys.
# Narrowing further would mean shipping a custom seccomp profile
# that allows exactly the ioctl smartctl needs — worth doing if
# this list of exceptions ever grows, not worth it for one pod.
seccompProfile:
type: Unconfined
volumeMounts:
- name: dev
mountPath: /dev
readOnly: true
# smartctl is not known to need scratch space, but the root
# filesystem is read-only and a tool that turns out to want /tmp
# would crashloop instead of degrading. Cheaper to provide it than
# to find out from a restart counter.
- name: tmp
mountPath: /tmp
resources:
requests:
cpu: 10m
memory: 32Mi
limits:
memory: 128Mi
livenessProbe:
httpGet:
path: /metrics
port: http-metrics
initialDelaySeconds: 15
periodSeconds: 30
volumes:
- name: dev
hostPath:
path: /dev
type: Directory
- name: tmp
emptyDir: {}
---
apiVersion: v1
kind: Service
metadata:
name: smartctl-exporter
namespace: monitoring
labels:
app.kubernetes.io/name: smartctl-exporter
spec:
clusterIP: None
selector:
app.kubernetes.io/name: smartctl-exporter
ports:
- name: http-metrics
port: 9633
targetPort: http-metrics
protocol: TCP
@@ -12,9 +12,11 @@
# * host namespaces + hostPath volumes: denied for every step pod (neither
# kaniko nor the buildx plugin needs them).
# * privileged containers: denied EXCEPT the allow-listed buildx plugin image.
# Verified non-breaking: this repo's own builds use rootless kaniko
# (gcr.io/kaniko-project/executor) which needs none of the above; only the
# external buildx plugin needs privileged, and it is allow-listed by image ref.
# Verified non-breaking: this repo's own builds use rootless kaniko, which needs
# none of the above; only the external buildx plugin needs privileged, and it is
# allow-listed by image ref. The kaniko image moved off gcr.io to the maintained
# chainguard-dev fork in #552 — no policy change was needed, because nothing
# here matches on the kaniko image, only on the buildx one.
#
# ValidatingAdmissionPolicy is GA / in-tree on the cluster's Kubernetes v1.35 —
# no external admission controller (Kyverno/Gatekeeper) is introduced.