@@ -108,12 +108,16 @@ spec:
|
||||
# identical `id`, differing `instance` — a real TSDB cardinality
|
||||
# cost that dashboards had to paper over with max by (id).
|
||||
#
|
||||
# Target the pve Service (apps ns) rather than a hardcoded node IP:
|
||||
# its EndpointSlice load-balances the PVE API across all three nodes,
|
||||
# so cluster metrics keep flowing as long as ANY node is up, instead
|
||||
# of pausing whenever .201 (jupiter) specifically is down. The
|
||||
# exporter reaches the API on 8006 (verify_ssl:false, so the LB'd
|
||||
# Target the pve Service (apps ns) rather than a hardcoded node IP,
|
||||
# so this job does not have to be edited when a node is renumbered.
|
||||
# The exporter reaches the API on 8006 (verify_ssl:false, so the LB'd
|
||||
# cert hostname mismatch is a non-issue).
|
||||
#
|
||||
# This is round robin, NOT failover: the EndpointSlice is hand-written
|
||||
# with `ready: true` asserted and nothing health-checks it. One scrape
|
||||
# makes several API calls, so a single down member fails 100% of this
|
||||
# job's scrapes rather than 1/N of them (issue #579). Keeping the
|
||||
# EndpointSlice free of decommissioned nodes is what keeps this job up.
|
||||
- job_name: pve
|
||||
static_configs:
|
||||
- targets:
|
||||
@@ -135,12 +139,12 @@ spec:
|
||||
# scraped — this is the split recommended by prometheus-pve-exporter
|
||||
# upstream to avoid the cluster-collector duplication above.
|
||||
# Targets are the node FQDNs, not raw IPs: the instance label then
|
||||
# reads jupiter/neptune/saturn.renner.uno, and a renumbered node is
|
||||
# picked up from DNS without editing this file.
|
||||
# reads neptune/saturn.renner.uno, and a renumbered node is picked up
|
||||
# from DNS without editing this file. jupiter is absent on purpose --
|
||||
# its hardware runs Talos as k8s-1 now and has no PVE API to scrape.
|
||||
- job_name: pve-node
|
||||
static_configs:
|
||||
- targets:
|
||||
- "jupiter.renner.uno"
|
||||
- "neptune.renner.uno"
|
||||
- "saturn.renner.uno"
|
||||
metrics_path: /pve
|
||||
|
||||
@@ -1,7 +1,17 @@
|
||||
# PVE node IPs are hardcoded here despite the general "IPs aren't static"
|
||||
# rule for the homelab: corosync requires stable cluster member identity,
|
||||
# so jupiter/neptune/saturn keep .201/.202/.203 across reboots and PVE
|
||||
# upgrades. If a node is permanently renumbered, edit this file.
|
||||
# so neptune/saturn keep .202/.203 across reboots and PVE upgrades. If a node
|
||||
# is permanently renumbered, edit this file.
|
||||
#
|
||||
# There are no health checks on these entries -- `ready: true` is asserted, not
|
||||
# observed -- so a member listed here that is down still takes its share of the
|
||||
# round robin. A decommissioned node must be REMOVED, not left in rotation:
|
||||
# the monitoring `pve` job makes several API calls per scrape, and any one of
|
||||
# them landing on a dead member fails the whole scrape (TargetDown, issue #579).
|
||||
#
|
||||
# jupiter (.201) was removed for exactly that reason: its MS-01 hardware now
|
||||
# runs Talos directly as k8s-1 and it is no longer a Proxmox node. See
|
||||
# kubernetes/talos/patches/k8s-1.yaml and .woodpecker/deploy-infrastructure.yml.
|
||||
apiVersion: discovery.k8s.io/v1
|
||||
kind: EndpointSlice
|
||||
metadata:
|
||||
@@ -16,11 +26,6 @@ ports:
|
||||
port: 8006
|
||||
protocol: TCP
|
||||
endpoints:
|
||||
- addresses:
|
||||
- 10.2.40.201
|
||||
hostname: jupiter
|
||||
conditions:
|
||||
ready: true
|
||||
- addresses:
|
||||
- 10.2.40.202
|
||||
hostname: neptune
|
||||
|
||||
@@ -167,17 +167,20 @@ spec:
|
||||
# impossible: the OSD is recreated within a reconcile and starts backfilling
|
||||
# onto the drive being replaced.
|
||||
#
|
||||
# k8s-1 is absent while jupiter's OSD drive is swapped and the node is
|
||||
# converted to bare metal. RE-ADD IT once the PM983 is in and the node has
|
||||
# rejoined; the cluster runs on two OSDs until then.
|
||||
#
|
||||
# nvme0n1 on k8s-2/k8s-3 is the NVMe drive PCI-passed-through from saturn and
|
||||
# neptune, and is the only block device those guests can see. Bare-metal k8s-1
|
||||
# will see two — the OSD drive in MS-01 slot 1 (PCI 01:00.0) and the Talos
|
||||
# system disk in slot 2 (58:00.0) — so when it is re-added, name its device
|
||||
# deliberately rather than assuming slot 1 keeps enumerating first. The system
|
||||
# disk is separately protected: talos/patches/k8s-1.yaml pins the installer to
|
||||
# it by serial, and Rook skips a disk carrying partitions.
|
||||
# neptune, and is the only block device those guests can see, so a bare device
|
||||
# name is unambiguous there.
|
||||
#
|
||||
# k8s-1 is bare metal and sees three NVMe drives, so it names its OSD by
|
||||
# /dev/disk/by-id path instead. A bare name would be actively wrong: Talos
|
||||
# enumerates this machine's drives in a different order than Proxmox did, and
|
||||
# nvme0n1 here is the Kingston SYSTEM disk. Rook would probably decline it for
|
||||
# carrying partitions, but that is luck rather than intent. The by-id path is
|
||||
# derived from model and serial and does not depend on enumeration at all.
|
||||
#
|
||||
# nvme0n1 50026B7382B48B86 Kingston — Talos system disk
|
||||
# nvme1n1 2332E86B749A Crucial — Talos EPHEMERAL (/var)
|
||||
# nvme2n1 S437NX0M400426 PM983 — this OSD
|
||||
storage:
|
||||
useAllNodes: false
|
||||
useAllDevices: false
|
||||
@@ -188,6 +191,9 @@ spec:
|
||||
- name: k8s-3
|
||||
devices:
|
||||
- name: nvme0n1
|
||||
- name: k8s-1
|
||||
devices:
|
||||
- fullpath: /dev/disk/by-id/nvme-SAMSUNG_MZQLB960HAJR-00007_S437NX0M400426
|
||||
config:
|
||||
osdsPerDevice: "1"
|
||||
# Storage layer must never be evicted by kubelet under node pressure
|
||||
|
||||
@@ -9,9 +9,6 @@
|
||||
# every link in one schema instead of straddling them.
|
||||
machine:
|
||||
network:
|
||||
# Shared control-plane VIP 10.2.40.60 is configured as a Layer2VIPConfig
|
||||
# below rather than machine.network.interfaces[].vip. Exposed via UniFi DNS
|
||||
# as k8s.renner.uno.
|
||||
hostname: k8s-1
|
||||
sysctls:
|
||||
# ens19 (VLAN 30, v30iot) is LINK ONLY — no host addressing. It exists as
|
||||
@@ -26,7 +23,7 @@ machine:
|
||||
install:
|
||||
# Three NVMe drives are ordinary block devices to Talos here: the Kingston
|
||||
# OM8PGP41024Q-A0 system disk, the Samsung PM983 that Rook claims as the
|
||||
# Ceph OSD, and the retired Crucial P3 that now carries EPHEMERAL (see the
|
||||
# Ceph OSD, and the retired Crucial P3 that carries EPHEMERAL (see the
|
||||
# VolumeConfig below). Every one of them is selected by serial. Nothing in
|
||||
# this file may use a broad selector: `disk.transport == 'nvme'` matches all
|
||||
# three, and the failure mode is Talos taking the OSD drive.
|
||||
@@ -51,9 +48,8 @@ cluster:
|
||||
#
|
||||
# THIS ONLY TAKES EFFECT ON FIRST PROVISION. Talos applies volume configuration
|
||||
# solely when the volume does not yet exist; a config applied after EPHEMERAL
|
||||
# has been created on the system disk is silently ignored, and relocating it
|
||||
# then requires wiping the disk and booting install media again. So this
|
||||
# document has to be present in the very first `apply-config --insecure`.
|
||||
# has been created elsewhere is silently ignored, and relocating it then
|
||||
# requires wiping the disk and booting install media again.
|
||||
#
|
||||
# Matched by serial deliberately. `disk.transport == 'nvme' && !system_disk`
|
||||
# would match the PM983 as well, and losing that coin flip means Talos formats
|
||||
@@ -67,42 +63,43 @@ provisioning:
|
||||
minSize: 50GiB
|
||||
grow: true
|
||||
---
|
||||
# Physical NICs are aliased by permanent MAC. Both X710 ports bind i40e, so the
|
||||
# driver selector k8s-2/k8s-3 use for their single passed-through port would
|
||||
# match two links here. MAC matching is unambiguous and survives udev renaming —
|
||||
# which is not hypothetical: adding the third NVMe renumbered the PCI buses and
|
||||
# moved the second I226 from enp89s0 to enp90s0.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkAliasConfig
|
||||
name: lan0
|
||||
selector:
|
||||
match: glob("58:47:ca:74:70:27", mac(link.permanent_addr))
|
||||
---
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkAliasConfig
|
||||
name: ceph0
|
||||
selector:
|
||||
match: glob("58:47:ca:74:70:28", mac(link.permanent_addr))
|
||||
---
|
||||
# lan0 is the switch trunk (X710 port 0). It carries no addressing of its own;
|
||||
# VLAN 40 and VLAN 30 ride on top. Proxmox's vlan-aware vmbr0 did this tagging
|
||||
# before, which is why the VM saw two already-untagged virtio NICs instead.
|
||||
# X710 port 0 carries the switch trunk. It takes no addressing itself — the
|
||||
# port's untagged VLAN is the 192.168.8.0/24 network, which this node has no
|
||||
# business being on — so management and v30iot both ride it as tagged VLANs.
|
||||
#
|
||||
# Links are addressed by predictable kernel name. Those derive from PCI
|
||||
# topology, not probe order — though not immune: adding the third NVMe
|
||||
# renumbered the buses and moved the unused second I226 from enp89s0 to
|
||||
# enp90s0. Neither name used here was affected.
|
||||
#
|
||||
# LinkAliasConfig would be the better way to pin these, and is worth
|
||||
# reintroducing — but only once it is proven. Aliasing both X710 ports by
|
||||
# permanent MAC and using the aliases as VLAN parents produced a node with no
|
||||
# address on any interface: the aliases were never created, so every document
|
||||
# referencing them did nothing, including the static address on port 1. Verify
|
||||
# any alias-based revision with `talosctl apply-config --mode=try`, which rolls
|
||||
# back on its own, before making it permanent.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: lan0
|
||||
name: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Management, VLAN 40. Carries the node IP, etcd, the API and Ceph's public
|
||||
# network. The k8s-1 VM reached 10.2.40.174 over this same physical port via
|
||||
# Proxmox's v40srv VNet (vmbr0.40), so the switch trunks VLAN 40 here.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: mgmt0
|
||||
vlanID: 40
|
||||
parent: lan0
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
apiVersion: v1alpha1
|
||||
kind: DHCPv4Config
|
||||
name: mgmt0
|
||||
---
|
||||
# Shared control-plane VIP, etcd-elected. Exposed via UniFi DNS as
|
||||
# k8s.renner.uno.
|
||||
apiVersion: v1alpha1
|
||||
kind: Layer2VIPConfig
|
||||
name: 10.2.40.60
|
||||
@@ -112,21 +109,20 @@ link: mgmt0
|
||||
# `master: ens19`, and k8s-2/k8s-3 still present the VLAN as a virtio NIC of
|
||||
# that name. VLANConfig.name is free-form, so keeping it lets one set of NADs
|
||||
# serve both VM and bare-metal nodes for as long as the cluster is mixed.
|
||||
# Nothing else on this machine is called ens19: the physical NICs are
|
||||
# enp2s0f0np0, enp2s0f1np1, enp87s0 and enp90s0.
|
||||
apiVersion: v1alpha1
|
||||
kind: VLANConfig
|
||||
name: ens19
|
||||
vlanID: 30
|
||||
parent: lan0
|
||||
parent: enp2s0f0np0
|
||||
up: true
|
||||
---
|
||||
# Dedicated Ceph cluster network, VLAN 49 / 10.99.0.0/29, untagged on the wire
|
||||
# on X710 port 1. Used by Rook for OSD<->OSD replication via
|
||||
# CephCluster.spec.network.addressRanges.cluster. No default route.
|
||||
# Dedicated Ceph cluster network on X710 port 1, VLAN 49 / 10.99.0.0/29,
|
||||
# untagged on the wire. Used by Rook for OSD<->OSD replication via
|
||||
# CephCluster.spec.network.addressRanges.cluster. Not routed off its own
|
||||
# segment, and deliberately has no default route.
|
||||
apiVersion: v1alpha1
|
||||
kind: LinkConfig
|
||||
name: ceph0
|
||||
name: enp2s0f1np1
|
||||
up: true
|
||||
mtu: 9000
|
||||
addresses:
|
||||
|
||||
Reference in New Issue
Block a user